M/077 - Thermal solar syst & component
Mandate to CEN/CENELEC on standards for thermal solar systems and components
General Information
This standard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in ENV 12977-1.
Stores tested according to this Prestandard are commonly used in solar hot water systems. However, also the thermal performance of all other thermal stores with water as storage medium (e.g. for heat pump systems) can be assessed according to this Prestandard.
The Prestandard applies to stores with a nominal volume between 50 and 3000 litres and without integrated oil or gas burner.
- Draft51 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in ENV 12977-1.
Stores tested according to this Prestandard are commonly used in solar hot water systems. However, also the thermal performance of all other thermal stores with water as storage medium (e.g. for heat pump systems) can be assessed according to this Prestandard.
The Prestandard applies to stores with a nominal volume between 50 and 3000 litres and without integrated oil or gas burner.
- Draft51 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements on durability, reliability and safety for Factory Made thermal solar heating systems. The standard also includes provisions for evaluation of conformity to these requirements.
The requirements in this standard apply to Factory Made solar systems as products. The installation of these systems itself is not considered, but requirements are given for the documentation for the installer and the user which is delivered with the system (see also 4.6).
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the requirements for Factory Made Thermal Solar Heating Systems as specified in EN 12976-1. The standard also includes two test methods for thermal performance characterization by means of whole system testing.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the requirements for Factory Made Thermal Solar Heating Systems as specified in EN 12976-1. The standard also includes two test methods for thermal performance characterization by means of whole system testing.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements on durability, reliability and safety for Factory Made thermal solar heating systems. The standard also includes provisions for evaluation of conformity to these requirements.
The requirements in this standard apply to Factory Made solar systems as products. The installation of these systems itself is not considered, but requirements are given for the documentation for the installer and the user which is delivered with the system (see also 4.6).
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the durability, reliability and safety requirements for liquid heating collectors as specified in EN 12975-1. This standard also includes three test methods for the thermal performance characterisation for liquid heating collectors.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes.
It is basically applicable to tracking concentrating collectors, thermal performance testing as given in 6.3 (quasi dynamic testing) is also applicable to most concentrating collector designs, from stationary non-imaging concentrators as CPCs to high concentrating tracking designs. Parts of the solar radiation measurement should be adjusted in case of a tracking collector and in case a pyrheliometer is used to measure beam radiation.
Collectors that are custom built (built in; e.g. roof integrated collectors that do not compose of factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector may be tested. The module gross area should be at least 2 m2. The test is valid only for larger collectors than the tested module.
- Standard140 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the durability, reliability and safety requirements for liquid heating collectors as specified in EN 12975-1. This standard also includes three test methods for the thermal performance characterisation for liquid heating collectors.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes.
It is basically applicable to tracking concentrating collectors, thermal performance testing as given in 6.3 (quasi dynamic testing) is also applicable to most concentrating collector designs, from stationary non-imaging concentrators as CPCs to high concentrating tracking designs. Parts of the solar radiation measurement should be adjusted in case of a tracking collector and in case a pyrheliometer is used to measure beam radiation.
Collectors that are custom built (built in; e.g. roof integrated collectors that do not compose of factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector may be tested. The module gross area should be at least 2 m2. The test is valid only for larger collectors than the tested module.
- Standard140 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is not applicable to tracking concentrating solar collectors.
Collectors that are custom-built (built in, roof integrated collectors that do not comprise factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector is tested. The module gross area in the case of custom built collectors should be at least 2 m2. The test is valid only for larger collectors, than the tested module.
For collectors the national and European Guidelines for Structural Planning and overhead glazing are not valid. Therefore this standard should be applied for the design of the static of the collector.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is not applicable to tracking concentrating solar collectors.
Collectors that are custom-built (built in, roof integrated collectors that do not comprise factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector is tested. The module gross area in the case of custom built collectors should be at least 2 m2. The test is valid only for larger collectors, than the tested module.
For collectors the national and European Guidelines for Structural Planning and overhead glazing are not valid. Therefore this standard should be applied for the design of the static of the collector.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Prestandard specifies requirements on durability, reliability and safety of small and large custom built solar heating systems with liquid heat transfer medium for residential buildings and similar applications. The Prestandard contains also requirements on the design process of large custom built systems.
- Standardization document17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Prestandard applies to small and large custom built solar heating systems with liquid heat transfer medium for residential buildings and similar applications, and gives test methods for verification of the requirements specified in ENV 12977-1.
This Prestandard includes also a method for thermal performance characterization and system performance prediction of small custom built systems by means of component testing and system simulation.
Furthermore, the Prestandard contains methods for thermal performance characterization and system performance prediction of large custom built systems.
This European Prestandard applies to the following types of small custom built solar heating systems:
- systems for domestic hot water preparation only;
- systems for space heating only;
- systems for domestic hot water preparation and space heating.
This European Prestandard applies to large custom built solar heating systems, primarily to solar preheat systems, with one or more storage vessels, heat exchangers, piping and automatic controls and with collector array(s) with forced circulation of fluid in the collector loop.
This Prestandard does not apply to:
- systems with a store medium other than water (e.g. phase-change materials);
- systems for space heating with a distribution fluid other than water for the space heating subsystem (e.g. air systems);
- small custom built systems with a circulation line entering any store having a feedback on the solar heated store.
Principally, systems with circulation line may be tested in accordance to the methods described in this Prestandard, if the connecting port for the circulation line is kept closed during the tests. This should, however, stated in the test report.
- Standardization document49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Prestandard applies to small and large custom built solar heating systems with liquid heat transfer medium for residential buildings and similar applications, and gives test methods for verification of the requirements specified in ENV 12977-1.
This Prestandard includes also a method for thermal performance characterization and system performance prediction of small custom built systems by means of component testing and system simulation.
Furthermore, the Prestandard contains methods for thermal performance characterization and system performance prediction of large custom built systems.
This European Prestandard applies to the following types of small custom built solar heating systems:
- systems for domestic hot water preparation only;
- systems for space heating only;
- systems for domestic hot water preparation and space heating.
This European Prestandard applies to large custom built solar heating systems, primarily to solar preheat systems, with one or more storage vessels, heat exchangers, piping and automatic controls and with collector array(s) with forced circulation of fluid in the collector loop.
This Prestandard does not apply to:
- systems with a store medium other than water (e.g. phase-change materials);
- systems for space heating with a distribution fluid other than water for the space heating subsystem (e.g. air systems);
- small custom built systems with a circulation line entering any store having a feedback on the solar heated store.
Principally, systems with circulation line may be tested in accordance to the methods described in this Prestandard, if the connecting port for the circulation line is kept closed during the tests. This should, however, stated in the test report.
- Standardization document49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Prestandard specifies requirements on durability, reliability and safety of small and large custom built solar heating systems with liquid heat transfer medium for residential buildings and similar applications. The Prestandard contains also requirements on the design process of large custom built systems.
- Standardization document17 pagesEnglish languagesale 10% offe-Library read for1 day
This Prestandard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in ENV 12977-1.
Stores tested according to this Prestandard are commonly used in solar hot water systems. However, also the thermal performance of all other thermal stores with water as storage medium (e.g. for heat pump systems) can be assessed according to this Prestandard.
The Prestandard applies to stores with a nominal volume between 50 and 3000 litres and without integrated oil or gas burner.
- Standardization document60 pagesEnglish languagesale 10% offe-Library read for1 day
This Prestandard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in ENV 12977-1.
Stores tested according to this Prestandard are commonly used in solar hot water systems. However, also the thermal performance of all other thermal stores with water as storage medium (e.g. for heat pump systems) can be assessed according to this Prestandard.
The Prestandard applies to stores with a nominal volume between 50 and 3000 litres and without integrated oil or gas burner.
- Standardization document60 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements on durability, reliability and safety for Factory Made thermal solar heating systems. The standard also includes provisions for evaluation of conformity to these require-ments.The requirements in this standard apply to Factory Made solar systems as products. The installation of these systems itself is not considered, but requirements are given for the documentation for the installer and the user which is delivered with the system (see also the clause 3).
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements. It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is not applicable to tracking concentrating solar collectors.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the durability, reliability and safety requirements for liquid heating collectors as specified in EN 12975-1. This standard also includes three test methods for the thermal performance characterisation for liquid heating collectors.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes.
It is not basically not applicable to tracking concentrating collectors, however thermal performance testing as given in clause 6.3 (quasi dynamic testing) is also applicable to most concentrating collector designs, from stationary non-imaging concentrators as CPCs to high concentrating tracking designs. Parts of the solar radiation measurement have to be adjusted in case of a tracking collector and in case a pyrheliometer is used to measure beam radiation.
Collectors that are custom built (built in; e.g. roof integrated collectors that do not compose of factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector may be tested. The module gross area shall be at least 2m2.
- Standard144 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the requirements for Factory Made Thermal Solar Heating Systems as specified in prEN 12976-1:2000. The standard also includes two test methods for thermal performance characterization by means of whole system testing.
- Standard56 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the durability, reliability and safety requirements for liquid heating collectors as specified in EN 12975-1. This standard also includes three test methods for the thermal performance characterisation for liquid heating collectors.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes.
It is not basically not applicable to tracking concentrating collectors, however thermal performance testing as given in clause 6.3 (quasi dynamic testing) is also applicable to most concentrating collector designs, from stationary non-imaging concentrators as CPCs to high concentrating tracking designs. Parts of the solar radiation measurement have to be adjusted in case of a tracking collector and in case a pyrheliometer is used to measure beam radiation.
Collectors that are custom built (built in; e.g. roof integrated collectors that do not compose of factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector may be tested. The module gross area shall be at least 2m2.
- Standard144 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements. It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is not applicable to tracking concentrating solar collectors.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements on durability, reliability and safety for Factory Made thermal solar heating systems. The standard also includes provisions for evaluation of conformity to these require-ments.The requirements in this standard apply to Factory Made solar systems as products. The installation of these systems itself is not considered, but requirements are given for the documentation for the installer and the user which is delivered with the system (see also the clause 3).
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for validating the requirements for Factory Made Thermal Solar Heating Systems as specified in prEN 12976-1:2000. The standard also includes two test methods for thermal performance characterization by means of whole system testing.