Standard Test Method for Thermal Conductivity of Refractory Brick

SCOPE
1.1 This test method supplements Test Method C201 and shall be used in conjunction with that test method to determine the thermal conductivity of refractory brick with the exception of insulating firebrick (use Test Method C182), and carbon refractories. This test method is designed for refractories having a conductivity factor of not more than 200 Btu[dot]in./h[dot]ft [dot]°F (28.8 W/m[dot]K).  
1.2 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are provided for information only.  
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Sep-1998
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C202-93(1998) - Standard Test Method for Thermal Conductivity of Refractory Brick
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 202 – 93 (Reapproved 1998)
Standard Test Method for
Thermal Conductivity of Refractory Brick
This standard is issued under the fixed designation C 202; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 3.2 This procedure must be used with Test Method C 201
and requires a large thermal gradient and steady state condi-
1.1 This test method supplements Test Method C 201 and
tions. The results are based upon a mean temperature.
shall be used in conjunction with that test method to determine
3.3 The data from this test method are suitable for specifi-
the thermal conductivity of refractory brick with the exception
cation acceptance, estimating heat loss and surface tempera-
of insulating firebrick (use Test Method C 182), and carbon
ture, and design of multi-layer refractory construction.
refractories. This test method is designed for refractories
3.4 The use of these data requires consideration of the actual
having a conductivity factor of not more than 200 Btu·in./
application environment and conditions.
h·ft ·°F (28.8 W/m·K).
1.2 The values stated in inch-pound units are to be regarded
4. Apparatus
as the standard. The values in parentheses are provided for
4.1 The apparatus shall consist of that described in Test
information only.
Method C 201 with the addition of thermocouples, back-up
1.3 This standard does not purport to address all of the
insulation, and refractory fiber paper as described in Sections 6
safety concerns, if any, associated with its use. It is the
and 7 of this test method.
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
5. Test Specimens
bility of regulatory limitations prior to use.
5.1 The test specimens shall be selected and prepared in
accordance with Test Method C 201.
2. Referenced Documents
2.1 ASTM Standards:
6. Installation of Thermocouples in Test Specimen
C 155 Classification of Insulating Firebrick
6.1 Thermocouples—Calibrated thermocouples shall be
C 182 Test Method for Thermal Conductivity of Insulating
embedded in the test specimen at two points for measuring
Firebrick
temperature. Platinum-10 % rhodium/platinum thermocouples
C 201 Test Method for Thermal Conductivity of Refracto-
shall be used. Wire of AWG Gage 28 (0.320 mm) shall be used
ries
in making the thermocouples.
E 220 Method for Calibration of Thermocouples by Com-
6.2 Installation of Thermocouples—The hot junction of the
parison Techniques
thermocouples shall be placed in the center of each 9- by
4 ⁄2-in. (228- by 114-mm) face and just below the surface of the
3. Significance and Use
test specimen. Grooves to receive the wire shall be cut in each
3.1 The thermal conductivity of refractory brick is a prop-
1 1
9- by 4 ⁄2-in. face of the brick to a depth of ⁄32in. (0.8 mm) by
erty required for selecting their thermal transmission charac-
means of an abrasive wheel 0.02 in. (0.5 mm) in thickness. The
teristics. Users select refractory brick to provide specified
layout for the grooves allows all of the cold junction ends of
conditions of heat loss and cold face temperature, without
the wires to extend from one end of the brick. A groove shall
exceeding the temperature limitation of the brick. This test
1 1
be cut in the center of each 9 by 4 ⁄2-in. face along the 4 ⁄2-in.
method establishes placement of thermocouples and position-
dimension and ending 1 in. (25 mm) from each edge. The path
ing of test specimens in the calorimeter.
of each groove is extended at an angle of 90° to one end of the
brick by cutting grooves parallel to and 1.0 in. from the edge
1 of the specimen. Before cementing the thermocouple wires in
This test method is under the jurisdiction of ASTM Committee C-8 on
Refractories and is the direct responsibility of Subcommittee C08.02 on Thermal place, measurements shall be taken to obtain, within 60.01 in.
Stress Resistance.
Current edition approved Dec. 15, 1993. Published February 1994. Originally
e1 4
published as C 202 – 45 T. Last previous edition C 202 – 84 (1993) . Method E 220 specifies calibration procedures for thermocouples.
2 5
Annual Book of ASTM Standards, Vol 15.01. Alundum Cement RA 562 supplied by the Norton Co., One New Bond St.,
Annual Book of ASTM Standards, Vol 14.03. Worcester, MA 01606, is satisfactory for this purpose.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
C 202
(0.3 mm), the eventual distance between the center lines of the strips of refractory fiber paper of the same dimensions shall be
thermocouple junctions. This shall be done by measuring the placed in the same pattern upon the back-up insulation. These
2 ⁄2-in. (64-mm) dimension of the brick at the location for the strips serve as spacers to prevent contact between the fireclay
hot junctions and deducting the distance between the center brick and the back-up insulation. The test specimen shall be
line of each junction in its embedded position and the surface placed centrally over the center of the calorimeter section on its
of the brick. 9- by 4 ⁄2-in. (228- by 114-mm) face, the guard brick placed at
the sides of the test specimen so as to cover completely the
7. Set-Up of Back-Up Insulation, Specimen, and Silicon
calorimeter and inner guard area, and the soap brick placed
Carbide Slab
along the edges of the three brick so as to cover completely the
calorimeter assembly. The small space between the furnace
7.1 The calorimeter and inner and outer guards shall be
walls and the test brick assembly shall be filled with granulated
covered with a 0.50-in. (12.7-mm) thick layer of Group 20
insulating firebrick.
insulating firebrick (see Classification C 155) for the purpose
7.3 The silicon carbide slab shall be placed over the 13 ⁄2-
of obtaining a higher mean temperature in the test specimen
by 9-in. (342- by 228-mm) area of the three 9-in. brick
than would result by placing the specimen directly over the
specimen, and it shall be spaced 1 in. (25 mm) above the
calorimeter area. The back-up insulation shall be cut and
specimen by placing under each corner of the slab rectangular
ground so as to provide surfaces that are plane and do not vary
pieces of Group 28 insulating firebrick cut to measure ⁄8-in.
from parallel by more than 60.01 in (0.3 mm). The sides of the
(10-mm) square and 1.00 in. (25.4 mm) in length.
pieces that are to be placed in contact shall be ground plane and
at rig
...