Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings

ABSTRACT
This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) sewer pipe and fittings. The pipe and fittings shall be homogeneous throughout and free from visible cracks, holes, foreign inclusions, or other injurious defects. The socket diameters, socket depth, wall thickness, pipe flattening, impact resistance, pipe stiffness, joint tightness, and extrusion quality shall be tested to meet the requirements prescribed.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) sewer pipe and fittings.  
1.2 Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.  
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification:   This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Oct-2015
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D3034-15 - Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM D3034-15 - Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D3034 −15
StandardSpecification for
Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and
1
Fittings
This standard is issued under the fixed designation D3034; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* (CPVC) Compounds
D2122Test Method for Determining Dimensions of Ther-
1.1 This specification covers requirements and test methods
moplastic Pipe and Fittings
for materials, dimensions, workmanship, flattening resistance,
D2152Test Method for Adequacy of Fusion of Extruded
impact resistance, pipe stiffness, extrusion quality, joining
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
systems and a form of marking for type PSM poly(vinyl
Acetone Immersion
chloride) (PVC) sewer pipe and fittings.
D2321PracticeforUndergroundInstallationofThermoplas-
1.2 Pipeandfittingsproducedtothisspecificationshouldbe
tic Pipe for Sewers and Other Gravity-Flow Applications
installed in accordance with Practice D2321.
D2412Test Method for Determination of External Loading
1.3 Thetextofthisspecificationreferencesnotes,footnotes,
Characteristics of Plastic Pipe by Parallel-Plate Loading
and appendixes which provide explanatory material. These
D2444Test Method for Determination of the Impact Resis-
notesandfootnotes(excludingthoseintablesandfigures)shall
tance of Thermoplastic Pipe and Fittings by Means of a
not be considered as requirements of the specification.
Tup (Falling Weight)
1.4 The values stated in inch-pound units are to be regarded D2564Specification for Solvent Cements for Poly(Vinyl
as standard. The values given in parentheses are mathematical
Chloride) (PVC) Plastic Piping Systems
conversions to SI units that are provided for information only
D2749Symbols for Dimensions of Plastic Pipe Fittings
and are not considered standard.
D2855Practice for Making Solvent-Cemented Joints with
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
1.5 The following precautionary caveat pertains only to the
test methods portion, Section 8, of this specification: This D3212Specification for Joints for Drain and Sewer Plastic
standard does not purport to address all of the safety concerns,
Pipes Using Flexible Elastomeric Seals
if any, associated with its use. It is the responsibility of the user F412Terminology Relating to Plastic Piping Systems
of this standard to establish appropriate safety and health
F1336Specification for Poly(Vinyl Chloride) (PVC) Gas-
practices and determine the applicability of regulatory limita-
keted Sewer Fittings
tions prior to use.
3
2.2 Federal Standard:
Fed. Std. No. 123Marking for Shipment (Civil Agencies)
2. Referenced Documents
3
2
2.3 Military Standard:
2.1 ASTM Standards:
MIL-STD-129Marking for Shipment and Storage
D618Practice for Conditioning Plastics for Testing
D1600TerminologyforAbbreviatedTermsRelatingtoPlas-
3. Terminology
tics
D1784Specification for Rigid Poly(Vinyl Chloride) (PVC)
3.1 Definitions—Definitions are in accordance with Termi-
Compounds and Chlorinated Poly(Vinyl Chloride)
nology F412, and abbreviations are in accordance with Termi-
nology D1600, unless otherwise specified.The abbreviation of
1
poly(vinyl chloride) plastics is PVC.
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
3.1.1 The term PSM is not an abbreviation but rather an
Current edition approved Nov. 1, 2015. Published December 2015. Originally
arbitrary designation for a product having certain dimensions.
approved in 1972. Last previous edition approved in 2014 as D3034–14a. DOI:
10.1520/D3034-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from DLA Document Services Building 4/D 700 Robbins Avenue
the ASTM website. Philadelphia, PA 19111-5094 http://quicksearch.dla.mil/
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D3034−15
TABLE 1 Pipe Dimensions
4. Significance and Use
Outside Diameter Minimum Wall Thickness
4.1 The requirements of this specification are intended to
Nominal
Tolerance SDR DR SDR DR
Size
provide pipe and fittings suitable for non-pressure drainage of
Average
on Average 41 35 26 23.5
sewage and surface water.
3 3.2
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D3034 − 14a D3034 − 15
Standard Specification for
Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and
1
Fittings
This standard is issued under the fixed designation D3034; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance,
impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC)
sewer pipe and fittings.
1.2 Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes
and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D2749 Symbols for Dimensions of Plastic Pipe Fittings
D2855 Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings
D3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
F412 Terminology Relating to Plastic Piping Systems
F1336 Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings
3
2.2 Federal Standard:
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Aug. 1, 2014Nov. 1, 2015. Published October 2014December 2015. Originally approved in 1972. Last previous edition approved in 2014 as
D3034 – 14.D3034 – 14a. DOI: 10.1520/D3034-14A.10.1520/D3034-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from DLA Document Services Building 4/D 700 Robbins Avenue Philadelphia, PA 19111-5094 http://quicksearch.dla.mil/
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D3034 − 15
3
2.3 Military Standard:
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 Definitions—Definitions are in accordance with Terminology F412, and abbreviations are in accordance with Terminology
D1600, unless otherwise specified. The abbreviation of poly(vinyl chloride) plastics is PVC.
3.1.1 The term PSM is not an abbrevia
...

Questions, Comments and Discussion