Standard Specification for High-Temperature Fiber Blanket Thermal Insulation

ABSTRACT
This specification covers the standard for high-temperature fiber blanket thermal insulation for use at various temperatures. The insulation should be tested and comply accordingly to physical and mechanical properties of the insulation such as apparent thermal conductivity, density, and temperature of use. The insulation shall also be tested for non-fibrous content, linear shrinkage, and tensile strength.
SCOPE
1.1 This specification covers high-temperature fiber blanket thermal insulation for use at various temperatures from 1350F (732C) up to 3000F (1649C), except when used in high-temperature furnaces.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.2 When the installation or use of thermal insulation materials, accessories, and systems may pose safety or health problems, the manufacturers shall provide the user with appropriate current information regarding any known problems associated with the recommended use of the company's products, and shall also recommend protective measures to be employed in their safe utilization. The user shall establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units which are provided for information only and are not considered standard.

General Information

Status
Historical
Publication Date
31-Oct-2005
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C892-05 - Standard Specification for High-Temperature Fiber Blanket Thermal Insulation
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C892 – 05
Standard Specification for
1
High-Temperature Fiber Blanket Thermal Insulation
This standard is issued under the fixed designation C892; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C177 Test Method for Steady-State Heat Flux Measure-
ments and Thermal Transmission Properties by Means of
1.1 This specification covers high-temperature fiber blanket
the Guarded-Hot-Plate Apparatus
thermalinsulationforuseatvarioustemperaturesfrom1350°F
C201 Test Method for Thermal Conductivity of Refracto-
(732°C) up to 3000°F (1649°C), except when used in high-
ries
temperature furnaces.
C209 Test Methods for Cellulosic Fiber Insulating Board
1.2 This standard does not purport to address all of the
C356 Test Method for Linear Shrinkage of Preformed
safety concerns, if any, associated with its use. It is the
High-Temperature Thermal Insulation Subjected to Soak-
responsibility of the user of this standard to establish appro-
ing Heat
priate safety and health practices and determine the applica-
C390 Practice for Sampling and Acceptance of Thermal
bility of regulatory limitations prior to use.
Insulation Lots
1.3 When the installation or use of thermal insulation
C1058 Practice for Selecting Temperatures for Evaluating
materials, accessories, and systems may pose safety or health
and Reporting Thermal Properties of Thermal Insulation
problems, the manufacturers shall provide the user with appro-
C1335 Test Method for Measuring Non-Fibrous Content of
priate current information regarding any known problems
Man-Made Rock and Slag Mineral Fiber Insulation
associated with the recommended use of the company’s
products, and shall also recommend protective measures to be
3. Terminology
employed in their safe utilization. The user shall establish
3.1 Definitions—Terminology C71 and Terminology C168
appropriate safety and health practices and determine the
shall be considered as applying to the terms used in this
applicability of regulatory requirements prior to use.
standard.
1.4 The values stated in inch-pound units are to be regarded
3.2 Definitions of Terms Specific to This Standard:
asthestandard.Thevaluesgiveninparenthesesaremathemati-
3.2.1 fibers—thefibersshallberefractoryoxides,processed
cal conversions to SI units which are provided for information
from a molten state into fibrous form.
only and are not considered standard.
3.2.2 high-temperature fiber thermal insulation— a thermal
2. Referenced Documents insulation, varying in flexibility, composed of refractory inor-
2 ganic fibers, with or without binder added, and furnished in
2.1 ASTM Standards:
either flat sheets or rolls.
C71 Terminology Relating to Refractories
C167 TestMethodsforThicknessandDensityofBlanketor
4. Classification
Batt Thermal Insulations
4.1 The general-type product governed by this specification
C168 Terminology Relating to Thermal Insulation
is blanket or batt composed of inorganic refractory fibers.
4.2 Types—The product is separated into types based upon
1
This specification is under the jurisdiction of ASTM Committee C16 on
temperatures of use:
Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on
Type Temperature of use, °F (°C), maximum
Blanket and Loose Fill Insulation.
I 1350 (732)
Current edition approved Nov. 1, 2005. Published December 2005. Originally
II 1600 (871)
approved in 1978. Last previous edition approved in 2000 as C892–00. DOI:
III 2400 (1316)
10.1520/C0892-05.
IV 2600 (1427)
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
V 3000 (1649)
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C892 – 05
TABLE 2 Physical and Mechanical Requirements
4.3 Grades—The product is separated into grades based
upon its density: Properties Requirements
3 3
Grade Density, lb/ft (kg/m ), nominal
Non-fibrous content (shot), maximum, % (by weight) 30
3 3 (48) Linear shrinkage, maximum, % (at maximum use 5
4 4 (64)
temperature)
2
6 6 (96) Tensile strength, minimum, lb/in (KPa)
8 8 (128) Grade 3 1.0 (6.9)
12 12 (192)
Grade 4 1.5 (10.3)
Grade 6 2.0 (13.8)
Grade 8 3.0 (20.7)
5. Ordering Information
Grade 12 5.0 (34.5)
5.1 High-temperature fiber blanket thermal insulation is
normally purchased on the basis of brand name, type, grade,
length, width, thickness, and total square footage as specified
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.