Standard Test Method for Measurement of Small Color Differences Between Ceramic Wall or Floor Tile

SCOPE
1.1 This test method covers the measurement of a visually small color difference between two pieces of solid-colored, glazed or unglazed ceramic tile, using any photoelectric instrument that meets the requirements specified in the test method. The amount and the direction of the color difference are expressed numerically, with sufficient accuracy for use in product specification.
1.2 This test method should not be used for determining small color differences between tile that have a multicolored, speckled, or textured surface, because the results may not be valid.
1.3 Color difference between specimens found to be metamers (see 3.2), by visual examination, can be accurately evaluated by spectrophotometric measurement only. Therefore, visual color comparison of test specimen and reference specimen should be made under incandescent light and under daylight fluorescent light before any instrumental measurement. If visual color difference under the two light sources is not of the same magnitude, the pair of tile must be considered metamers.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Dec-1999
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C609-90(2000) - Standard Test Method for Measurement of Small Color Differences Between Ceramic Wall or Floor Tile
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C609–90(Reapproved 2000)
Standard Test Method for
Measurement of Small Color Differences Between Ceramic
1
Wall or Floor Tile
This standard is issued under the fixed designation C609; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope E259 Practice for Preparation of Pressed Powder White
Reflectance Factor Transfer Standards for Hemispherical
1.1 This test method covers the measurement of a visually
3
Geometry
small color difference between two pieces of solid-colored,
3
E284 Terminology of Appearance
glazed or unglazed ceramic tile, using any photoelectric
instrument that meets the requirements specified in the test
3. Terminology
method. The amount and the direction of the color difference
3.1 Definitions:
are expressed numerically, with sufficient accuracy for use in
3.1.1 color difference, DE—the vector sum of the three
product specification.
component differences DL, Da, and Db. It is expressed in units
1.2 This test method should not be used for determining
of judds and may be computed by the equation shown under
small color differences between tile that have a multicolored,
9.7.The values DL, Da, and Db are obtained by calculating the
speckled, or textured surface, because the results may not be
component differences as follows:
valid.
DL 5 L 2 L
1.3 Colordifferencebetweenspecimensfoundtobemetam-
t r
ers (see 3.2), by visual examination, can be accurately evalu-
Da 5 a 2 a
t r
ated by spectrophotometric measurement only. Therefore, vi-
Db 5 b 2 b
t r
sualcolorcomparisonoftestspecimenandreferencespecimen
should be made under incandescent light and under daylight where:
fluorescent light before any instrumental measurement. If t = test specimen, and
r = reference specimen.
visual color difference under the two light sources is not of the
The quantity DE has a positive value and it describes the
same magnitude, the pair of tile must be considered metamers.
magnitudebutnotthedirectionofcolordifferencebetweenthe
1.4 The values stated in inch-pound units are to be regarded
test specimen and the reference specimen. The direction of
as the standard. The values given in parentheses are for
information only. color difference depends upon the algebraic signs of the
components DL, Da, and Db. A positive DL value means that
1.5 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the the test specimen is lighter than the reference against which it
is being compared, and a negative DLvalue means that the test
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica- specimen is darker. However, the algebraic signs of chroma-
ticity components, Da and Db, do not convey an easily
bility of regulatory limitations prior to use.
visualized difference in color attributes and can best be
2. Referenced Documents
visualized by plotting the corresponding points in the chroma-
4
2.1 ASTM Standards: ticity plane.
C242 Terminology of Ceramic Whitewares and Related 3.1.2 color space—the colors of opaque specimens such as
2
Products ceramic tile are described in terms of three color scales L, a,
D2244 Test Method for Calculation of Color Differences and b. Scale L is a measure of lightness, a is a measure of
3
redness or greenness, and b is a measure of yellowness or
from Instrumentally Measured Color Coordinates
blueness. The units for each of the three scales are so chosen
that they represent equally perceptible color differences. The
interrelation of these color scales is more readily visualized if
1
This test method is under the jurisdiction of ASTM Committee C-21 on
the scales are represented geometrically as the three mutually
Ceramic Whitewares and Related Products and is the direct responsibility of
Subcommittee C21.06 on Ceramic Tile.
Current edition approved Dec. 28, 1990. Published February 1991. Originally
4
published as C609–67. Last previous edition C609–86. Illing, A. M., Balinkin, I., “Precision in Measurement of Small Color
2
Annual Book of ASTM Standards, Vol 15.02. Differences,” American Ceramic Society Bulletin, Vol 44, No. 12, 1965, pp.
3
Annual Book of ASTM Standards, Vol 06.01. 956–962.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C609
perpendicularaxesofathree-dimensionalcolorspace,withthe enough information, since its magnitude gives a fairly good
L axis in the vertical direction, the positive a axis (redness) to correlation with huma
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.