Standard Test Method for Oil Separation from Lubricating Grease (Conical Sieve Method)

SIGNIFICANCE AND USE
5.1 When lubricating grease separates oil, the residual material may change in consistency, which can affect the ability of the product to function as designed. Test results obtained with this procedure are not intended to predict oil separation tendencies of grease under dynamic service conditions.  
5.2 This test method is used for specifications and quality control.
SCOPE
1.1 This test method covers the determination of the tendency of lubricating grease to separate oil at an elevated temperature. This test method shall be conducted at 100 °C for 30 h unless other conditions are required by the grease specification.  
1.2 This test method can be used on any grease with a worked penetration (Test Methods D217) greater than 220 mm/10 (NLGI Consistency Number 3 or softer). However, no precision data exists for greases with a penetration greater than 340 mm/10 (softer than NLGI Consistency Number 1).  
1.3 The values stated in SI units are to be regarded as standard. The term 60 mesh is used to describe the wire mesh used. This unit was described in the withdrawn E437 standard and there is no exact metric equivalent.  
1.4 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
30-Apr-2017
Current Stage
Ref Project

Buy Standard

Standard
ASTM D6184-17 - Standard Test Method for Oil Separation from Lubricating Grease (Conical Sieve Method)
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D6184-17 - Standard Test Method for Oil Separation from Lubricating Grease (Conical Sieve Method)
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D6184 − 17
Standard Test Method for
Oil Separation from Lubricating Grease (Conical Sieve
1
Method)
This standard is issued under the fixed designation D6184; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
INTRODUCTION
The conical sieve method for measuring leakage from lubricating grease (commonly known as the
cone bleed test) uses the same equipment as the obsolete, withdrawn FED-STD-791C (Federal Test
Method (FTM) 791C) Method 321.3, Oil Separation from Lubricating Grease (Static Technique).
Despite the lack of a precision statement, Method 321.3 was used for many years in specifications to
evaluate the tendencies of base fluid separation from military and industrial greases. Test Method
D6184 supersedes the FTM method by overcoming deficiencies of Method 321.3. It includes the
proceduresandprecisiondeterminationsresultantfromacooperativestudyconductedbyparticipating
members of Subcommittee D02.G0.
1. Scope* Development of International Standards, Guides and Recom-
mendations issued by the World Trade Organization Technical
1.1 This test method covers the determination of the ten-
Barriers to Trade (TBT) Committee.
dency of lubricating grease to separate oil at an elevated
temperature. This test method shall be conducted at 100 °C for
2. Referenced Documents
30 h unless other conditions are required by the grease speci-
2
2.1 ASTM Standards:
fication.
D217 Test Methods for Cone Penetration of Lubricating
1.2 This test method can be used on any grease with a
Grease
worked penetration (Test Methods D217) greater than
D1742 Test Method for Oil Separation from Lubricating
220 mm⁄10(NLGIConsistencyNumber3orsofter).However,
Grease During Storage
no precision data exists for greases with a penetration greater
E437 Specification for Industrial Wire Cloth and Screens
than 340 mm⁄10 (softer than NLGI Consistency Number 1).
(Square Opening Series) (Discontinued 2000) Replaced
3
1.3 The values stated in SI units are to be regarded as
by E 2016 (Withdrawn 2000)
standard. The term 60 mesh is used to describe the wire mesh
2.2 Government Standard (Withdrawn):
used. This unit was described in the withdrawn E437 standard
FED-STD-791C Lubricants, Liquid Fuels, and Related
and there is no exact metric equivalent.
Products; Methods of Testing, Method 321.3 “Oil Sepa-
ration from Lubricating Greases (Static Technique),”
1.4 This standard does not purport to address all the safety
4
Withdrawn November 2007
concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety
3. Terminology
practices and determine the applicability of regulatory limita-
tions prior to use.
3.1 Definitions:
1.5 This international standard was developed in accor-
3.1.1 lubricating grease, n—a semifluid to solid product of
dance with internationally recognized principles on standard-
a dispersion of a thickener in a liquid lubricant.
ization established in the Decision on Principles for the
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
1
This test method is under the jurisdiction of ASTM Committee D02 on contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of Standards volume information, refer to the standard’s Document Summary page on
Subcommittee D02.G0.03 on Physical Tests the ASTM website.
3
Current edition approved May 1, 2017. Published June 2017. Originally The last approved version of this historical standard is referenced on
approved in 1997. Last previous edition approved in 2016 as D6184 – 16. DOI: www.astm.org.
4
10.1520/D6184-17. Available online at ASSIST Quick Search (http://quicksearch.dla.mil).
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6184 − 17
NOTE 1—Dimensions are provided in millimetres (with in./lb. units in parentheses) as follows:
A – 38.1 ± 0.3 (1.50 ± 0.01) radius
B – 27.0 ± 0.3 (1.06 ± 0.01) height
C – 70 (2.8) approximately (to fit beaker)
D – 9.7 ± 3.3 (0.38 ± 0.13) length
E – 100 (4) approximately
F – 36 (1.4) approximately
FIG. 1 Cone Fabrication and Test Setup
3.1.1.1 Discussion—The dispersion of the thickener forms a 5.2 This test method is used for specifications and quality
two-phase system and immobilizes the liquid lubricant
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D6184 − 16 D6184 − 17
Standard Test Method for
Oil Separation from Lubricating Grease (Conical Sieve
1
Method)
This standard is issued under the fixed designation D6184; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
INTRODUCTION
The conical sieve method for measuring leakage from lubricating grease (commonly known as the
cone bleed test) uses the same equipment as the obsolete, withdrawn Federal FED-STD-791C (Federal
Test Method (FTM) 791C791C) Method 321.3, Oil Separation from Lubricating Grease (Static
Technique). Despite the lack of a precision statement, Method 321.3 was used for many years in
specifications to evaluate the tendencies of base fluid separation from military and industrial greases.
Test Method D6184 supersedes the FTM method by overcoming deficiencies of Method 321.3. It
includes the procedures and precision determinations resultant from a cooperative study conducted by
participating members of Subcommittee D02.G0 of Committee D02.D02.G0.
1. Scope*
1.1 This test method covers the determination of the tendency of lubricating grease to separate oil at an elevated temperature.
This test method shall be conducted at 100 °C for 30 h unless other conditions are required by the grease specification.
1.2 This test method is suitable for use with most all greases, but the test precision was established using greases having can
be used on any grease with a worked penetration (Test Methods D217) greater than 220220 mm ⁄10 (NLGI No. 3 grade) and less
than 340Consistency Number 3 or softer). However, no precision data exists for greases with a penetration greater than 340 mm
(NLGI No. 1 grade).⁄10 (softer than NLGI Consistency Number 1).
1.3 The values stated in SI units are to be regarded as standard. The term 60 mesh was originally described in the now
withdrawnis used to describe the wire mesh E437 standard. It is used to describe the wireused. This unit was described in the
withdrawn E437 mesh becausestandard and there is no exact metric equivalent.
1.4 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of
the user of this standard to establish appropriate safety practices and determine the applicability of regulatory limitations prior
to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D217 Test Methods for Cone Penetration of Lubricating Grease
D1742 Test Method for Oil Separation from Lubricating Grease During Storage
E437 Specification for Industrial Wire Cloth and Screens (Square Opening Series) (Discontinued 2000) Replaced by E 2016
3
(Withdrawn 2000)
1
This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of Subcommittee
D02.G0.03 on Physical Tests
Current edition approved Sept. 1, 2016May 1, 2017. Published September 2016June 2017. Originally approved in 1997. Last previous edition approved in 20142016 as
D6184 – 14.D6184 – 16. DOI: 10.1520/D6184-16.10.1520/D6184-17.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6184 − 17
2.2 Government Standard (Withdrawn):
Federal Test Method (FTM) 791C 321.3,FED-STD-791C Oil Lubricants, Liquid Fuels, and Related Products; Methods of
Testing, Method 321.3 “Oil Separation from Lubricating Greases (Static Technique)—Withdrawn Technique),” Withdrawn
4
November 2007
3. Termin
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.