Standard Test Method for Effective Porosity and Effective Air Voids of Compacted Asphalt Mixture Samples

SIGNIFICANCE AND USE
4.1 In this test method, a compacted sample is vacuum sealed inside a plastic bag. The density of the sample, SG1, is calculated using a water displacement method, with the sample sealed. With the sample still in water, the bag is cut open. Since the sample is under vacuum and the air voids are evacuated, water will rush in to fill all the water-accessible air voids in the compacted sample. With the saturated weight of sample known, an apparent maximum density, SG2, can be calculated. The difference between SG2 and SG1 is the measure of the amount of water that has penetrated the compacted sample. This difference can be used to determine the fraction of total number of voids that are accessible to water, effective percent porosity or percent effective air voids.  
4.2 The results obtained from this method can be used to determine the percentage of total air voids in a compacted sample that can be filled with water through surface or interconnected paths within the sample. In general, effective percent porosity should be less than total percent air voids.  
Note 1: The quality of the results produced by this standard are dependent on the competence of the personnel performing the procedure and the capability, calibration, and maintenance of the equipment used. Agencies that meet the criteria of Specification D3666 are generally considered capable of competent and objective testing, sampling, inspection, etc. Users of this standard are cautioned that compliance with Specification D3666 alone does not completely ensure reliable results. Reliable results depend on many factors; following the suggestions of Specification D3666 or some similar acceptable guideline provides a means of evaluating and controlling some of those factors.  
4.3 This method can be used for 100 mm [4 in.] and 150 mm [6 in.] diameter cylindrical samples and cubical samples.
SCOPE
1.1 This test method covers the determination of effective porosity or effective air voids of compacted mixtures by the use of a vacuum sealing method.  
1.2 This method can be used for compacted field and laboratory asphalt mixture samples, as well as other compacted samples with well-defined geometrical shapes, such as concrete cylinders, cored rocks, and metal samples.  
1.3 The results of this test method can be used to determine the degree of interconnectivity of air voids within a sample and can be correlated to permeability of compacted asphalt mixture samples.  
1.4 A multi-laboratory precision and bias statement for this standard has not been developed at this time. Therefore, this standard should not be used for acceptance or rejection of a material for purchasing purposes.  
1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.  
1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
14-Aug-2018
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D7063/D7063M-18 - Standard Test Method for Effective Porosity and Effective Air Voids of Compacted Asphalt Mixture Samples
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D7063/D7063M-18 - Standard Test Method for Effective Porosity and Effective Air Voids of Compacted Asphalt Mixture Samples
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D7063/D7063M − 18
Standard Test Method for
Effective Porosity and Effective Air Voids of Compacted
1
Asphalt Mixture Samples
This standard is issued under the fixed designation D7063/D7063M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Development of International Standards, Guides and Recom-
mendations issued by the World Trade Organization Technical
1.1 This test method covers the determination of effective
Barriers to Trade (TBT) Committee.
porosityoreffectiveairvoidsofcompactedmixturesbytheuse
of a vacuum sealing method.
2. Referenced Documents
1.2 This method can be used for compacted field and 2
2.1 ASTM Standards:
laboratoryasphaltmixturesamples,aswellasothercompacted
D8Terminology Relating to Materials for Roads and Pave-
samples with well-defined geometrical shapes, such as con-
ments
crete cylinders, cored rocks, and metal samples.
D979/D979MPractice for Sampling Bituminous Paving
1.3 The results of this test method can be used to determine Mixtures
thedegreeofinterconnectivityofairvoidswithinasampleand D3666Specification for Minimum Requirements for Agen-
canbecorrelatedtopermeabilityofcompactedasphaltmixture cies Testing and Inspecting Road and Paving Materials
samples. D4753Guide for Evaluating, Selecting, and Specifying Bal-
ances and Standard Masses for Use in Soil, Rock, and
1.4 Amulti-laboratory precision and bias statement for this
Construction Materials Testing
standard has not been developed at this time. Therefore, this
D5361/D5361MPractice for Sampling Compacted Asphalt
standard should not be used for acceptance or rejection of a
Mixtures for Laboratory Testing
material for purchasing purposes.
D7227/D7227MPractice for Rapid Drying of Compacted
1.5 The values stated in either SI units or inch-pound units
Asphalt Mixture Specimens Using Vacuum DryingAppa-
are to be regarded separately as standard. The values stated in
ratus
each system may not be exact equivalents; therefore, each
E691Practice for Conducting an Interlaboratory Study to
system shall be used independently of the other. Combining
Determine the Precision of a Test Method
values from the two systems may result in nonconformance
with the standard. 3. Terminology
1.6 The text of this standard references notes and footnotes
3.1 For definitions of terms used in this standard, refer to
whichprovideexplanatorymaterial.Thesenotesandfootnotes Terminology D8.
(excluding those in tables and figures) shall not be considered
4. Significance and Use
as requirements of the standard.
4.1 In this test method, a compacted sample is vacuum
1.7 This standard does not purport to address all of the
sealed inside a plastic bag. The density of the sample, SG1, is
safety concerns, if any, associated with its use. It is the
calculatedusingawaterdisplacementmethod,withthesample
responsibility of the user of this standard to establish appro-
sealed.Withthesamplestillinwater,thebagiscutopen.Since
priate safety, health, and environmental practices and deter-
the sample is under vacuum and the air voids are evacuated,
mine the applicability of regulatory limitations prior to use.
waterwillrushintofillallthewater-accessibleairvoidsinthe
1.8 This international standard was developed in accor-
compacted sample. With the saturated weight of sample
dance with internationally recognized principles on standard-
known,anapparentmaximumdensity,SG2,canbecalculated.
ization established in the Decision on Principles for the
The difference between SG2 and SG1 is the measure of the
amount of water that has penetrated the compacted sample.
1
This test method is under the jurisdiction of ASTM Committee D04 on Road
and Paving Materials and is the direct responsibility of Subcommittee D04.21 on
2
Specific Gravity and Density of Asphalt Mixtures. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved on Aug. 15, 2018. Published August 2018. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
published in 2005. Last approved in 2017 as D7063/D7063M–17. DOI: 10.1520/ Standards volume information, refer to the standard’s Document Summary page on
D7063_D7063M-18. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D7063/D7063M − 18
This difference can be used to determine the fractio
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D7063/D7063M − 17 D7063/D7063M − 18
Standard Test Method for
Effective Porosity and Effective Air Voids of Compacted
1
Asphalt Mixture Samples
This standard is issued under the fixed designation D7063/D7063M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the determination of effective porosity or effective air voids of compacted mixtures by the use of
a vacuum sealing method.
1.2 This method can be used for compacted field and laboratory asphalt mixture samples, as well as other compacted samples
with well-defined geometrical shapes, such as concrete cylinders, cored rocks, and metal samples.
1.3 The results of this test method can be used to determine the degree of interconnectivity of air voids within a sample and
can be correlated to permeability of compacted asphalt mixture samples.
1.4 A multi-laboratory precision and bias statement for this standard has not been developed at this time. Therefore, this
standard should not be used for acceptance or rejection of a material for purchasing purposes.
1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalent;equivalents; therefore, each system shall be used independently of the other. Combining values
from the two systems may result in nonconformance with the standard.
1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of the standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory requirementslimitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D8 Terminology Relating to Materials for Roads and Pavements
D979/D979M Practice for Sampling Bituminous Paving Mixtures
D3666 Specification for Minimum Requirements for Agencies Testing and Inspecting Road and Paving Materials
D4753 Guide for Evaluating, Selecting, and Specifying Balances and Standard Masses for Use in Soil, Rock, and Construction
Materials Testing
D5361/D5361M Practice for Sampling Compacted Asphalt Mixtures for Laboratory Testing
D7227/D7227M Practice for Rapid Drying of Compacted Asphalt Mixture Specimens Using Vacuum Drying Apparatus
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
3. Terminology
3.1 For definitions of terms used in this standard, refer to Terminology D8.
1
This test method is under the jurisdiction of ASTM Committee D04 on Road and Paving Materials and is the direct responsibility of Subcommittee D04.21 on Specific
Gravity and Density of Asphalt Mixtures.
Current edition approved on June 15, 2017Aug. 15, 2018. Published June 2017August 2018. Originally published in 2005. Last approved in 20112017 as
D7063/D7063M – 11.D7063/D7063M – 17. DOI: 10.1520/D7063_D7063M-17.10.1520/D7063_D7063M-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D7063/D7063M − 18
4. Significance and Use
4.1 In this test method, a compacted sample is vacuum sealed inside a plastic bag. The density of the sample, SG1, is calculated
using a water displacement method, with the sample sealed. With the sample still in water, the bag is cut open. Since the sample
is under vacuum and the air voids are evacuated, water will rush in to fill all th
...

Questions, Comments and Discussion