SIGNIFICANCE AND USE
This practice provides a guide to any individual, group, agency, or code body on the methods of test for truss assemblies fabricated from all types of construction materials. Sample size is generally kept to a minimum to reduce costs. The methods may be used to apply proof loads to an assembly or to test it to failure. Information obtained includes strength and stiffness data, and if assemblies are tested to their ultimate load carrying capacity, the failure method or mechanism can be observed.
SCOPE
1.1 This practice is intended as a guide for use in the testing of truss assemblies fabricated from all types of construction materials. While the practice may be used for the testing of a variety of assemblies, it is primarily intended to be used in the testing of those trusses designed to be spaced at 1.2 m (48 in.) centers or greater. It can be used, but it is not normally intended, for the testing of wood residential trussed rafters. Either proof tests or tests to destruction may be run.
1.2 Limitations—It is not intended that this practice be used for routine quality control testing.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E73 − 83(Reapproved 2007)
Standard Practice for
Static Load Testing of Truss Assemblies
This standard is issued under the fixed designation E73; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope by change in momentum of the load and structural elements
can be neglected and all parts of the system at any instant are
1.1 This practice is intended as a guide for use in the testing
essentially in equilibrium.
of truss assemblies fabricated from all types of construction
materials. While the practice may be used for the testing of a 3.3 For other definitions in this practice, see Terminology
variety of assemblies, it is primarily intended to be used in the E631.
testing of those trusses designed to be spaced at 1.2 m (48 in.)
4. Summary of Practice
centers or greater. It can be used, but it is not normally
intended, for the testing of wood residential trussed rafters.
4.1 This practice outlines the procedures to be followed in
Either proof tests or tests to destruction may be run.
the static load testing of major load carrying truss assemblies.
While the procedure tells what to do, it does not tell the testing
1.2 Limitations—It is not intended that this practice be used
agency how to do it.This leaves the selection of the test fixture
for routine quality control testing.
and loading medium to the discretion of the testing agency.
1.3 This standard does not purport to address all of the
Materials selection, sampling, conditioning, fabrication, test
safety concerns, if any, associated with its use. It is the
procedures, and report requirements are covered.
responsibility of the user of this standard to establish appro-
4.2 Two types of tests may be conducted using this practice:
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. For specific hazard 4.2.1 Proof Tests—A proof test is frequently made to pro-
vide assurance that the truss will support a stated load or to
statements, see Section 7.
determine the deformations and structural response under a
2. Referenced Documents
specified loading.
4.2.2 Test to Failure—In testing to failure, more detailed
2.1 ASTM Standards:
information is generally desired such as ultimate load carrying
E196 Practice for Gravity Load Testing of Floors and Low
capacity, total load-deflection history, yield point, connection
Slope Roofs
performance, factor of safety, etc.
E575 Practice for Reporting Data from Structural Tests of
4.2.3 If desired, either type of test may be extended to
Building Constructions, Elements, Connections, and As-
include a determination of the magnitude and distribution of
semblies
the stresses in the members and connections in order to permit
E631 Terminology of Building Constructions
a more comprehensive analysis of the truss performance.
3. Terminology
5. Significance and Use
3.1 truss—a coplanar system of structural elements joined
5.1 This practice provides a guide to any individual, group,
together at their ends usually to construct a series of triangles
agency, or code body on the methods of test for truss
that form a stable beam-like framework.
assemblies fabricated from all types of construction materials.
3.2 static load—a load or series of loads that are supported
Sample size is generally kept to a minimum to reduce costs.
by or are applied to a structure so gradually that forces caused
The methods may be used to apply proof loads to an assembly
or to test it to failure. Information obtained includes strength
1 and stiffness data, and if assemblies are tested to their ultimate
This practice is under the jurisdiction of ASTM Committee E06 on Perfor-
mance of Buildings and is the direct responsibility of Subcommittee E06.11 on
loadcarryingcapacity,thefailuremethodormechanismcanbe
Horizontal and Vertical Structures/Structural Performance of Completed Structures.
observed.
Current edition approved April 1, 2007. Published April 2007. Originally
approved in 1948. Last previous edition approved in 2002 as E73 – 83 (2002). DOI:
6. Test Apparatus
10.1520/E0073-83R07.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
6.1 General—While the methods described in this proce-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
dure are best suited to tests of trusses before installation in a
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. structure, they can also be applied to the testing of trusses after
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
E73 − 83 (2007)
installation. In the former case, the truss may be tested in either fully employed as a loading medium. The arrangement of dead
a vertical position (normal or inverted) or in a horizontal loadmaterialshallbesuchastopreventanyarchingactionthat
position. Additional loadings must be applied to trusses tested can seriously alter the intended load pattern. When water is
in an inverted or horizontal position to compensate for the used, care shall be taken to compartmentalize the water in cells
effect of dead loads and gravity. Regardless of the orientation topreventanon-uniformloadasthetrussandelementsdeflect.
of the truss in the test fixture, the fixture and load application Air bags reacting against restraint frames have also been used.
means shall be designed with an ample margin of safety to
6.4 Load and Deflection Measuring Devices
ensure that it is the test specimen that is being tested and not
6.4.1 Load Measuring Devices—Loads may be measured
the test fixture. More information on the testing of components
using one or more of the following devices. Pressure gages or
in existing structures is contained in Practice E196.
hydraulic load cells can be incorporated into a hydraulic
6.2 Supports and Reactions:
loading system. These devices must be calibrated with the
6.2.1 The reaction supports shall provide sufficient clear-
jacks or cylinders at different positions of piston travel to
ance above the ground or restraint frame to allow for normal
ensure a true loading history. Spring dynamometers, electronic
displacements, ease of loading, instrumentation, and provide
load cells, or the weighing tables of universal testing machines
room for observations and measurements. Supports shall have
havealsobeensuccessfullyused.Theloadmeasuringdeviceor
adequate strength and stiffness to resist deformations during
devices used shall be capable of measuring loads to an
tests.
accuracy of 6 2 % of design load.
6.2.2 Support reaction hardware shall be typical of that
6.4.2 Deflection Measuring Devices:
planned for use in the completed structure or as required to
6.4.2.1 Deflection readings may be taken in a variety of
satisfy the intent of the tests. In a single truss test, frequently
ways. One of the simplest methods is by the use of a taut wire
the support at one end will allow rotation but not translation (a
or mono-filament line stretched between supports in combina-
rocker) and the other will allow both rotation and translation (a
tion with a mirror-scale located at the desired deflection
roller) so as not to induce additional unintentional secondary
measuring points. Such a device avoids any magnification of
stresses into the test truss as it deforms under load.
deflection readings due to a settlement of supports during
6.2.3 Where lateral support is used, it shall not interfere
loading.When the taut wire method is used, care must be taken
with the free in-plane displacement of the truss assembly. The
to ensure that the wire will remain under tension during the
testtrussesshallnotbelaterallysupportedinamannerthatwill
entire test. This can be accomplished by incorporating a spring
exceed that intended in a typical installation. Trusses tested in
into the line or by letting one end run over a pulley with a
pairs shall be laterally braced and sheathed in a typical manner.
weight attached to the line. Deflections are read on a scale with
Lateralbracingbetweentrussestestedinpairsshallbeinstalled
a mirror backing.The mirror-scale deflection measuring device
in a manner to prevent both trusses from buckling together.
is read by visually lining up the top of the wire with its image
Care shall be taken when testing trusses horizontally to keep
on the mirror and then reading the scale.
the test truss flat to minimize any adverse lateral displacement
6.4.2.2 Other commonly used devices are such things as
caused by gravity.
direct reading micrometer dial gages, optical levels used to
6.3 Loading Devices:
read scales attached to the truss, linearly variable differential
6.3.1 The loading devices shall result in the desired truss transformers (LVDT), or a combination of flexible wire at-
loading situation regardless of whether uniform, concentrated, tached at deflection points and monitored remotely through a
or a combination of both. The system shall be such as to allow system of pulleys attached to dial gages. Deflection readings
the application of loads during the test to approximate the and measuring devices shall have an accuracy of 6 2% of
overall intended in-service load distribution. Care should be design load deflection.
taken to avoid eccentrically applied loads unless this type of
6.4.3 Strain Measurements—Strain measurements may be
loading is desired.
taken on truss elements using electrical or mechanical strain
6.3.2 Vertical loads may be applied in the form of dead
gages. Approximate stress distribution and magnitude may be
weight through bearing, suspension, or jacking arrangements.
observed by the application of special brittle lacquers to the
Horizontal loads are usually applied by some form of jacking
areas of interest.All of these measurements should be made by
arrangement directly in-plane or by using a system of cables
personnel experienced in the application and operation of the
and pulleys with dead weights or hydraulic cylinders. The
methods employed on the material being tested.
loading system should have provisions for applying unbal-
6.5 Typical Setups—Some suggested setups for running
anced loads when this type of loading can be critical to truss
truss tests are shown in Figs. 1-3.
performance (see 9.4). Uplift forces such as those caused by
wind loads may be simulated by reversing the direction of the
7. Hazards
applied gravity loads; or if the fixture will permit it, testing the
truss upside down. It is preferable to test the truss in its
7.1 Full-scale load tests of any large siz
...