SIGNIFICANCE AND USE
4.1 The procedures outlined will provide data that can be used to evaluate the relative performance of wall, floor, and roof constructions under conditions representative of those sustained in actual service when subjected to impact by a heavy blunt object. See Test Method E661 for evaluation of floor and roof sheathing and Practice E73 for evaluation of roof trusses.
4.2 The method is intended to be applied to relatively light construction, including, but not limited to, wood floor and roof systems, partitions framed with wood or steel studs, steel floor or roof decking systems, steel siding and wall panels, or thin concrete and masonry walls or slabs and similar assemblies.
SCOPE
1.1 This test method covers the measurement of the relative resistance of wall, floor, and roof construction to impact loading. The test is not applicable to doors.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
8.1 The procedures described are those that will test the behavior of segments of wall construction under conditions representative of those encountered in service. Performance criteria based on data from those procedures can ensure structural adequacy and service life.
SCOPE
1.1 These test methods cover the following procedures for determining the structural properties of segments of wall, floor, and roof constructions:
Section
Test Specimens
3
Loading
4
Deformation Measurements
5
Reports
6
Precision and Accuracy
7
TESTING WALLS
Significance and Use
8
Compressive Load
9
Tensile Load
10
Transverse Load—Specimen Horizontal
11
Transverse Load—Specimen Vertical
12
Concentrated Load
13
Impact Load—See Test Methods E695 and E661
Racking Load—Evaluation of Sheathing Materials
on a Standard Wood Frame
14
Racking Load—Evaluation of Sheathing Materials (Wet)
on a Standard Wood Frame
15
TESTING FLOORS
Significance and Use
16
Transverse Load
17
Concentrated Load
18
Impact Load—See Test Methods E695 and E661
TESTING ROOFS
Section
Significance and Use
19
Transverse Load
20
Concentrated Load
21
APPENDIX
Technical Interpretation
Appendix X1
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard14 pagesEnglish language
- Standard14 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Transverse Load—The procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.
4.2 Concentrated Load—This concentrated load test shall be used to evaluate surface indentation of structural framing members.
4.3 These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Test Method E455. Impact loading shall be evaluated under Test Methods E661 or E695.
SCOPE
1.1 This test method covers the following procedures for determining the structural properties of segments of floor and roof constructions:
Section
Test Specimens
5
Loading
6
Deformation Measurements
7
Report
8
Precision and Bias
9
Testing Floors
Transverse Load
10
Concentrated Load
11
Testing Roofs
Transverse Load
12
Concentrated Load
13
1.2 This test method serves to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing or supporting members (floor joist, rafters, and trusses), or both.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.
1.4 This standard is not intended to cover concrete floor slabs.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The procedures outlined will provide data that can be used to evaluate the structural performance, under concentrated loads, of roof and floor sheathing, separate from the effects of the framing, under simulated conditions representative of those in actual service.
5.2 The procedures are intended to be applied to roof or floor sheathing materials installed directly to framing. They are not intended for the evaluation of the framed assembly as a whole.
SCOPE
1.1 This test method covers procedures for determining the resistance to deflection and damage of floor and roof sheathing used in site-built construction subjected to concentrated static loads as well as impact loads from nonrigid blunt objects. It is applicable to wood and wood-based panels and boards, but is not intended to cover profiled metal decks, nor precast or cast-in-place slabs. Surface indentation is not evaluated separately from deflection.
1.2 Three applications are covered: roof sheathing, subfloors, and single floors. Roof sheathing is tested in both a dry and a wet condition, while subfloors and single floors are both tested in a dry condition, as well as a condition of having dried out after being wet. These moisture conditions are those commonly experienced with site-built construction.
Note 1: Where it is anticipated that sheathing will be subjected only to dry conditions during construction and use, or else to greater moisture exposure than is indicated in 7.3.2, the corresponding exposure conditions may be modified by agreement between the interested parties. For example, shop-built construction may be tested dry only, although the possibility of exposure to high humidity or leaks and flooding during use should be considered.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The compressive properties obtained by axial compression will provide information such as: modulus of elasticity, stress at proportional limit and compressive strength for the end support, and lateral bracing condition tested.
5.2 This test method addresses only full-sized specimens for determination of compressive strength and compressive modulus of elasticity intended for application to actual length members with end conditions and lateral bracing as intended.
Note 1: The effective length of the column with respect to buckling is affected by the end conditions. A fixed end condition results in an effective length for buckling that is less than the actual length of the column, by as much as 50 %.
SCOPE
1.1 This test method covers the evaluation of vertical members in axial compression for “full-sized” specimens with various end conditions with constant cross-sections throughout the length.
1.2 This test method is limited to reinforced plastic and polymer matrix composite materials and covers the determination of the compressive properties of structural members. The method is intended primarily for members of rectangular cross section, but is also applicable to irregularly shaped studs, round posts, or special sections.
1.3 This test method covers short-term axial load testing under standard indoor atmospheric conditions. It does not address: sampling, the ability of the material to carry a sustained long-term load, design load derivations, temperature effects, performance under freeze/thaw or salt spray exposure conditions, chemical/UV exposure effects, or engineering analysis/modeling needed to extrapolate the results to conditions other than those tested. Each of these factors, and potentially others, need to be considered by the design professional or product standard development committee before using the information generated by this test method to assess structural adequacy.
1.4 Short sections are not covered in this test method and should be tested using a material test standard such as Test Method D6108 or Test Methods D198.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 SIPs are used as roof, wall, and floor components in building structures. The structural performance properties need to be determined for design purposes.
SCOPE
1.1 These test methods cover procedures for determining strength properties under specified loads for rigid-faced structural insulated panels. These test methods are appropriate for structural insulated panels with rigid facings having a minimum thickness of 0.16 in. (4 mm) and an insulating core with a minimum thickness of 1.5 in. (38 mm). These specified loads include:
1.1.1 Transverse loads,
1.1.2 Axial loads,
1.1.3 Shear loads,
1.1.4 Diaphragm loads,
1.1.5 Uplift loads,
1.1.6 Long Term loads
1.1.7 Impact loads, and
1.1.8 Concentrated loads.
1.2 Structural insulated panels are intended to resist structural loads in permanent building structures.
1.3 These test methods are not intended for quality control purposes and do not evaluate the individual components of the structural insulated panels.
1.4 These test methods are not intended to measure dimensional stability.
1.5 The text of this standard references notes and footnotes, excluding tables and figures, which provide explanatory information. These notes and footnotes shall not be considered requirements of the standard.
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The test protocol evaluates those complex suspended ceiling systems that cannot be assessed by simple engineering calculations contained in ASCE/SEI 7 and Practice E580/E580M. It is not intended to replace the requirements in ASCE/SEI 7. Suspended ceiling systems are considered nonstructural components of buildings.
SCOPE
1.1 These test methods help evaluate the performance of a full-scale suspended ceiling system during a seismic event using a dynamic seismic simulator (shake table).
1.2 These full-scale procedures are not the only available procedures for evaluating the seismic performance of ceiling systems. These tests do not preclude the use of other small-scale or full-scale component or system testing.
1.3 These test methods contain two independent procedures.
1.3.1 Comparative method where the level of performance of an experimental system is compared to that of a control test system under the same set of conditions.
1.3.2 Non-comparative method where a single test is conducted to establish the level of performance of an experimental system.
1.4 These test procedures are valid and useful for all types of suspended ceiling systems.
1.5 The text of this standard uses notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice provides a guide to any individual, group, agency, or code body on the methods of test for truss assemblies fabricated from all types of construction materials. Sample size is generally kept to a minimum to reduce costs. The methods may be used to apply proof loads to an assembly or to test it to failure. Information obtained includes strength and stiffness data, and if assemblies are tested to their ultimate load carrying capacity, the failure method or mechanism can be observed.
SCOPE
1.1 This practice is intended as a guide for use in the testing of truss assemblies fabricated from all types of construction materials. While the practice may be used for the testing of a variety of assemblies, it is primarily intended to be used in the testing of those trusses designed to be spaced at 1.2 m centers or greater. It can be used, but it is not normally intended, for the testing of wood residential trussed rafters. Either proof tests or tests to destruction may be run.
1.2 Limitations—It is not intended that this practice be used for routine quality control testing.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 These cyclic test methods are intended to measure the performance of vertical elements of the lateral force resisting system subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the specimens.
5.2 The monotonic test is intended to provide data from a continuous displacement ramp loading of a matched test specimen with boundary conditions identical to the specimens that will be cyclically tested. The results from the monotonic test, when employed, are primarily intended for defining the amplitudes of load cycles for the three cyclic protocols.
Note 2: The monotonic test is not intended to serve as an equivalent alternative to the cyclic protocols of this Test Method or the procedures of Test Methods E72 or Practice E564.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Framed floor and roof systems are tested by this test method for static shear capacity. This test method will help determine structural diaphragm properties needed for design purposes.
SCOPE
1.1 This test method covers procedures designed (1) to evaluate the static shear capacity of a typical segment of a framed diaphragm under simulated loading conditions, and (2) to provide a determination of the stiffness of the construction and its connections. A diaphragm construction is an assembly of materials designed to transmit shear forces in the plane of the construction.
1.2 No effort has been made to specify the test apparatus, as there are a number that can be used as long as the needs of the testing agency are met. If round-robin testing is to be conducted, test apparatus and testing procedures shall be mutually agreed upon in advance by the participants.
1.3 The text of this standard contains notes and footnotes that provide explanatory information and are not requirements of the standard. Notes and footnotes in tables and figures are requirements of this standard.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The procedures outlined in these test methods serve to evaluate the performance of the wall segments for deflection, permanent set, and maximum load-carrying capacity under transverse loading. Performance criteria based on data collected using these procedures fall outside the scope of these test methods.
4.2 Transverse loads cannot be applied satisfactorily to some wall constructions, such as masonry, with the specimen in a horizontal position. For such constructions, the loads shall be applied to the specimen in a vertical position thus simulating service conditions.
4.3 Test results obtained from the two-point loading (8.2.1 and 9.2.1) and the uniform loading (8.2.2 and 9.2.2) are neither compatible nor interchangeable.
SCOPE
1.1 These test methods cover transverse load testing to determine the structural properties of wall segments.
1.2 These test methods serve to evaluate the performance of wall panels subject to transverse bending loads applied perpendicular to the plane of the wall. The tests are conducted on horizontal or vertical specimens under two-point loading. It also shall be permitted to apply uniform load using an air bag or a vacuum chamber. Depending upon the configuration tested, these loads are intended to evaluate the transverse deflection, permanent set, and maximum flexural capacity or planar shear capacity, or both, of the wall segment. These test methods are not intended for the evaluation of individual structural framing or supporting members (floor joist, decking, etc.), or both. The connections between the vertical elements of the wall segment and the surrounding construction are excluded from the scope of these methods and shall be evaluated by alternative means.
1.3 Notes and footnotes in this standard provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this standard.
1.4 The values stated in SI units are to be regarded as standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice provides a standard procedure for reporting data and results of structural tests used for building constructions, elements, corrections, and assemblies. It enumerates and discusses the report sections required to report data from test methods and practices. The written reports will describe the products tested, method of testing, and results.
SCOPE
1.1 This practice covers general use in reporting structural performance tests of building constructions, elements, connections, and assemblies. A comprehensive report describing the conditions under which the structural data were recorded will enable other workers to reproduce the test methods and, as nearly as possible, the results for each material or assembly, and to reconcile differences that might be found in tests by others.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SCOPE
1.1 This practice describes methods for evaluating the shear capacity of a typical section of a framed wall, supported on a rigid foundation and having load applied in the plane of the wall along the edge opposite the rigid support and in a direction parallel to it. The objective is to provide a determination of the shear stiffness and strength of any structural light-frame wall configuration to be used as a shear-wall on a rigid support.
1.2 Limitations—This practice is not intended to be used as a basis for classifying sheathing shear capacity or as an evaluation of combined flexure and shear resulting from the wall being loaded on a flexible foundation.
1.2.1 The effect of sheathing variations is assessed by holding all other variables constant. Permitted variations in framing configuration and boundary conditions, however, require accurate documentation of the test setup to validate across-study comparisons of sheathing contribution to wall shear capacity.
Note 1: A wall tested on a flexible foundation is evaluated by comparing shear stiffness and strength results to those of an identical wall tested on a rigid foundation, following this practice. However, no methods are given for the measurement of wall bending displacements or assessment of stress distribution resulting from foundation flexure. Any extrapolation of wall racking behavior from the foundation conditions specified by this practice to flexible conditions shall be done with the support of a comparative test on a representative foundation.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice is intended to be used by parties involved in the testing of floors and roofs of structures either in the field or the laboratory. Tests are either proof tests or tests to failure, and are applicable to all construction materials. The practice is not intended for use in routine quality control testing of individual building elements or constructions.
SCOPE
1.1 This practice covers static load testing of floors and low slope roofs (roofs having a slope of less than 1 in 12) under actual or simulated service conditions, and is applicable to typical elements or sections of structures fabricated for test or to actual existing building components. This practice is intended for use in determining the strength and stiffness of elements or sections of floors and roofs of buildings under gravity loads, as well as in checking the design, materials, connections, and the quality of the fabrication of such building constructions.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SCOPE
1.1 This guide covers the flexural testing of beams and girders under simulated service conditions to determine their structural performance characteristics. Methods following this guide are intended primarily for constructions that may not conform with the relatively simple assumptions upon which well-known flexural theories are based. In some cases, they are also suitable for determining the structural adequacy of the design, materials, connections, and fabrication techniques. The methods are not intended for use in routine quality control tests.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statement, see 7.1.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The test protocol evaluates those complex suspended ceiling systems that cannot be assessed by simple engineering calculations contained in ASCE/SEI 7 and Practice E580/E580M. It is not intended to replace the requirements in ASCE/SEI 7. Suspended ceiling systems are considered nonstructural components of buildings.
SCOPE
1.1 These test methods help evaluate the performance of a full-scale suspended ceiling system during a seismic event using a dynamic seismic simulator (shake table).
1.2 These full-scale procedures are not the only available procedures for evaluating the seismic performance of ceiling systems. These tests do not preclude the use of other small-scale or full-scale component or system testing.
1.3 These test methods contain two independent procedures.
1.3.1 Comparative method where the level of performance of an experimental system is compared to that of a control test system under the same set of conditions.
1.3.2 Non-comparative method where a single test is conducted to establish the level of performance of an experimental system.
1.4 These test procedures are valid and useful for all types of suspended ceiling systems.
1.5 The text of this standard uses notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The test protocol evaluates those complex suspended ceiling systems that cannot be assessed by simple engineering calculations contained in ASCE/SEI 7 and Practice E580/E580M. It is not intended to replace the requirements in ASCE/SEI 7. Suspended ceiling systems are considered nonstructural components of buildings.
SCOPE
1.1 These test methods help evaluate the performance of a full-scale suspended ceiling system during a seismic event using a dynamic seismic simulator (shake table).
1.2 These full-scale procedures are not the only available procedures for evaluating the seismic performance of ceiling systems. These tests do not preclude the use of other small-scale or full-scale component or system testing.
1.3 These test methods contain two independent procedures.
1.3.1 Comparative method where the level of performance of an experimental system is compared to that of a control test system under the same set of conditions.
1.3.2 Non-comparative method where a single test is conducted to establish the level of performance of an experimental system.
1.4 These test procedures are valid and useful for all types of suspended ceiling systems.
1.5 The text of this standard uses notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 These test methods are intended to measure the performance of vertical elements of the lateral force resisting system subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the specimens.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The procedures outlined in these test methods serve to evaluate the performance of the wall segments for deflection, permanent set, and maximum load-carrying capacity under transverse loading. Performance criteria based on data collected using these procedures fall outside the scope of these test methods.
4.2 Transverse loads cannot be applied satisfactorily to some wall constructions, such as masonry, with the specimen in a horizontal position. For such constructions, the loads shall be applied to the specimen in a vertical position thus simulating service conditions.
4.3 Test results obtained from the two-point loading (8.2.1 and 9.2.1) and the uniform loading (8.2.2 and 9.2.2) are neither compatible nor interchangeable.
SCOPE
1.1 These test methods cover transverse load testing to determine the structural properties of wall segments.
1.2 These test methods serve to evaluate the performance of wall panels subject to transverse bending loads applied perpendicular to the plane of the wall. The tests are conducted on horizontal or vertical specimens under two-point loading. It also shall be permitted to apply uniform load using an air bag or a vacuum chamber. Depending upon the configuration tested, these loads are intended to evaluate the transverse deflection, permanent set, and maximum flexural capacity or planar shear capacity, or both, of the wall segment. These test methods are not intended for the evaluation of individual structural framing or supporting members (floor joist, decking, etc.), or both. The connections between the vertical elements of the wall segment and the surrounding construction are excluded from the scope of these methods and shall be evaluated by alternative means.
1.3 Notes and footnotes in this standard provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this standard.
1.4 The values stated in SI units are to be regarded as standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Framed floor and roof systems are tested by this test method for static shear capacity. This test method will help determine structural diaphragm properties needed for design purposes.
SCOPE
1.1 This test method covers procedures designed (1) to evaluate the static shear capacity of a typical segment of a framed diaphragm under simulated loading conditions, and (2) to provide a determination of the stiffness of the construction and its connections. A diaphragm construction is an assembly of materials designed to transmit shear forces in the plane of the construction.
1.2 No effort has been made to specify the test apparatus, as there are a number that can be used as long as the needs of the testing agency are met. If round-robin testing is to be conducted, test apparatus and testing procedures shall be mutually agreed upon in advance by the participants.
1.3 The text of this standard contains notes and footnotes that provide explanatory information and are not requirements of the standard. Notes and footnotes in tables and figures are requirements of this standard.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
8.1 The procedures described are those that will test the behavior of segments of wall construction under conditions representative of those encountered in service. Performance criteria based on data from those procedures can ensure structural adequacy and service life.
SCOPE
1.1 These test methods cover the following procedures for determining the structural properties of segments of wall, floor, and roof constructions:
Section
Test Specimens
3
Loading
4
Deformation Measurements
5
Reports
6
Precision and Accuracy
7
TESTING WALLS
Significance and Use
8
Compressive Load
9
Tensile Load
10
Transverse Load—Specimen Horizontal
11
Transverse Load—Specimen Vertical
12
Concentrated Load
13
Impact Load—See Test Methods E695 and E661
Racking Load—Evaluation of Sheathing Materials
on a Standard Wood Frame
14
Racking Load—Evaluation of Sheathing Materials (Wet)
on a Standard Wood Frame
15
TESTING FLOORS
Significance and Use
16
Transverse Load
17
Concentrated Load
18
Impact Load—See Test Methods E695 and E661
TESTING ROOFS
Section
Significance and Use
19
Transverse Load
20
Concentrated Load
21
APPENDIX
Technical Interpretation
Appendix X1
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.2.1 Exception—SI units are used in Fig. 6.
- Standard13 pagesEnglish language
- Standard13 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The compressive properties obtained by axial compression will provide information such as: modulus of elasticity, stress at proportional limit and compressive strength for the end support, and lateral bracing condition tested.
5.2 This test method addresses only full-sized specimens for determination of compressive strength and compressive modulus of elasticity intended for application to actual length members with end conditions and lateral bracing as intended.
Note 1: The effective length of the column with respect to buckling is affected by the end conditions. A fixed end condition results in an effective length for buckling that is less than the actual length of the column, by as much as 50 %.
SCOPE
1.1 This test method covers the evaluation of vertical members in axial compression for “full-sized” specimens with various end conditions with constant cross-sections throughout the length.
1.2 This test method is limited to reinforced plastic and polymer matrix composite materials and covers the determination of the compressive properties of structural members. The method is intended primarily for members of rectangular cross section, but is also applicable to irregularly shaped studs, round posts, or special sections.
1.3 This test method covers short-term axial load testing under standard indoor atmospheric conditions. It does not address: sampling, the ability of the material to carry a sustained long-term load, design load derivations, temperature effects, performance under freeze/thaw or salt spray exposure conditions, chemical/UV exposure effects, or engineering analysis/modeling needed to extrapolate the results to conditions other than those tested. Each of these factors, and potentially others, need to be considered by the design professional or product standard development committee before using the information generated by this test method to assess structural adequacy.
1.4 Short sections are not covered in this test method and should be tested using a material test standard such as Test Method D6108 or Test Methods D198.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Transverse Load—The procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.
4.2 Concentrated Load—This concentrated load test shall be used to evaluate surface indentation of structural framing members.
4.3 These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Test Method E455. Impact loading shall be evaluated under Test Methods E661 or E695.
SCOPE
1.1 This test method covers the following procedures for determining the structural properties of segments of floor and roof constructions:
Section
Test Specimens
5
Loading
6
Deformation Measurements
7
Report
8
Precision and Bias
9
Testing Floors
Transverse Load
10
Concentrated Load
11
Testing Roofs
Transverse Load
12
Concentrated Load
13
1.2 This test method serves to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing or supporting members (floor joist, rafters, and trusses), or both.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.
1.4 This standard is not intended to cover concrete floor slabs.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The procedures outlined will provide data that can be used to evaluate the relative performance of wall, floor, and roof constructions under conditions representative of those sustained in actual service when subjected to impact by a heavy blunt object. See Test Method E661 for evaluation of floor and roof sheathing and Practice E73 for evaluation of roof trusses.
4.2 The method is intended to be applied to relatively light construction, including, but not limited to, wood floor and roof systems, partitions framed with wood or steel studs, steel floor or roof decking systems, steel siding and wall panels, or thin concrete and masonry walls or slabs and similar assemblies.
SCOPE
1.1 This test method covers the measurement of the relative resistance of wall, floor, and roof construction to impact loading. The test is not applicable to doors.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The procedures outlined will provide data that can be used to evaluate the structural performance, under concentrated loads, of roof and floor sheathing, separate from the effects of the framing, under simulated conditions representative of those in actual service.
5.2 The procedures are intended to be applied to roof or floor sheathing materials installed directly to framing. They are not intended for the evaluation of the framed assembly as a whole.
SCOPE
1.1 This test method covers procedures for determining the resistance to deflection and damage of floor and roof sheathing used in site-built construction subjected to concentrated static loads as well as impact loads from nonrigid blunt objects. It is applicable to wood and wood-based panels and boards, but is not intended to cover profiled metal decks, nor precast or cast-in-place slabs. Surface indentation is not evaluated separately from deflection.
1.2 Three applications are covered: roof sheathing, subfloors, and single floors. Roof sheathing is tested in both a dry and a wet condition, while subfloors and single floors are both tested in a dry condition, as well as a condition of having dried out after being wet. These moisture conditions are those commonly experienced with site-built construction.
Note 1: Where it is anticipated that sheathing will be subjected only to dry conditions during construction and use, or else to greater moisture exposure than is indicated in 7.3.2, the corresponding exposure conditions may be modified by agreement between the interested parties. For example, shop-built construction may be tested dry only, although the possibility of exposure to high humidity or leaks and flooding during use should be considered.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
8.1 The procedures described are those that will test the behavior of segments of wall construction under conditions representative of those encountered in service. Performance criteria based on data from those procedures can ensure structural adequacy and service life.
SCOPE
1.1 These test methods cover the following procedures for determining the structural properties of segments of wall, floor, and roof constructions:
Section
Test Specimens
3
Loading
4
Deformation Measurements
5
Reports
6
Precision and Accuracy
7
TESTING WALLS
Significance and Use
8
Compressive Load
9
Tensile Load
10
Transverse Load—Specimen Horizontal
11
Transverse Load—Specimen Vertical
12
Concentrated Load
13
Impact Load—See Test Methods E695 and E661
Racking Load—Evaluation of Sheathing Materials
on a Standard Wood Frame
14
Racking Load—Evaluation of Sheathing Materials (Wet)
on a Standard Wood Frame
15
TESTING FLOORS
Significance and Use
16
Transverse Load
17
Concentrated Load
18
Impact Load—See Test Methods E695 and E661
TESTING ROOFS
Section
Significance and Use
19
Transverse Load
20
Concentrated Load
21
APPENDIX
Technical Interpretation
Appendix X1
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.2.1 Exception—SI units are used in Fig. 6.
- Standard13 pagesEnglish language
- Standard13 pagesEnglish language
SIGNIFICANCE AND USE
8.1 The procedures described are those that will test the behavior of segments of wall construction under conditions representative of those encountered in service. Performance criteria based on data from those procedures can ensure structural adequacy and service life.
SCOPE
1.1 These test methods cover the following procedures for determining the structural properties of segments of wall, floor, and roof constructions:
Section
Test Specimens
3
Loading
4
Deformation Measurements
5
Reports
6
Precision and Accuracy
7
TESTING WALLS
Significance and Use
8
Compressive Load
9
Tensile Load
10
Transverse Load—Specimen Horizontal
11
Transverse Load—Specimen Vertical
12
Concentrated Load
13
Impact Load—See Test Methods E695 and E661
Racking Load—Evaluation of Sheathing Materials
on a Standard Wood Frame
14
Racking Load—Evaluation of Sheathing Materials (Wet)
on a Standard Wood Frame
15
TESTING FLOORS
Significance and Use
16
Transverse Load
17
Concentrated Load
18
Impact Load—See Test Methods E695 and E661
TESTING ROOFS
Section
Significance and Use
19
Transverse Load
20
Concentrated Load
21
APPENDIX
Technical Interpretation
Appendix X1
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.2.1 Exception—SI units are used in Fig. 6.
- Standard13 pagesEnglish language
- Standard13 pagesEnglish language
SIGNIFICANCE AND USE
5.1 SIPs are used as roof, wall, and floor components in building structures. The structural performance properties need to be determined for design purposes.
SCOPE
1.1 These test methods cover procedures for determining strength properties under specified loads for rigid-faced structural insulated panels. These test methods are appropriate for structural insulated panels with rigid facings having a minimum thickness of 0.16 in. (4 mm) and an insulating core with a minimum thickness of 1.5 in. (38 mm). These specified loads include:
1.1.1 Transverse loads,
1.1.2 Axial loads,
1.1.3 Shear loads,
1.1.4 Diaphragm loads,
1.1.5 Uplift loads,
1.1.6 Long Term loads
1.1.7 Impact loads, and
1.1.8 Concentrated loads.
1.2 Structural insulated panels are intended to resist structural loads in permanent building structures.
1.3 These test methods are not intended for quality control purposes and do not evaluate the individual components of the structural insulated panels.
1.4 These test methods are not intended to measure dimensional stability.
1.5 The text of this standard references notes and footnotes, excluding tables and figures, which provide explanatory information. These notes and footnotes shall not be considered requirements of the standard.
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
8.1 The procedures described are those that will test the behavior of segments of wall construction under conditions representative of those encountered in service. Performance criteria based on data from those procedures can ensure structural adequacy and service life.
SCOPE
1.1 These test methods cover the following procedures for determining the structural properties of segments of wall, floor, and roof constructions:
Section
Test Specimens
3
Loading
4
Deformation Measurements
5
Reports
6
Precision and Accuracy
7
TESTING WALLS
Significance and Use
8
Compressive Load
9
Tensile Load
10
Transverse Load—Specimen Horizontal
11
Transverse Load—Specimen Vertical
12
Concentrated Load
13
Impact Load—See Test Methods E695 and
E661
Racking Load—Evaluation of Sheathing
Materials on a Standard Wood Frame
14
Racking Load—Evaluation of Sheathing
Materials (Wet) on a Standard Wood
Frame
15
TESTING FLOORS
Significance and Use
16
Transverse Load
17
Concentrated Load
18
Impact Load—See Test Methods E695 and
E661
TESTING ROOFS
Section
Significance and Use
19
Transverse Load
20
Concentrated Load
21
APPENDIX
Technical Interpretation
Appendix X1
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.2.1 Exception—SI units are used in Fig. 6.
- Standard12 pagesEnglish language
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
8.1 The procedures described are those that will test the behavior of segments of wall construction under conditions representative of those encountered in service. Performance criteria based on data from those procedures can ensure structural adequacy and service life.
SCOPE
1.1 These test methods cover the following procedures for determining the structural properties of segments of wall, floor, and roof constructions:
Section
Test Specimens
3
Loading
4
Deformation Measurements
5
Reports
6
Precision and Accuracy
7
TESTING WALLS
Significance and Use
8
Compressive Load
9
Tensile Load
10
Transverse Load—Specimen Horizontal
11
Transverse Load—Specimen Vertical
12
Concentrated Load
13
Impact Load—See Test Methods E695 and
E661
Racking Load—Evaluation of Sheathing
Materials on a Standard Wood Frame
14
Racking Load—Evaluation of Sheathing
Materials (Wet) on a Standard Wood
Frame
15
TESTING FLOORS
Significance and Use
16
Transverse Load
17
Concentrated Load
18
Impact Load—See Test Methods E695 and
E661
TESTING ROOFS
Section
Significance and Use
19
Transverse Load
20
Concentrated Load
21
APPENDIX
Technical Interpretation
Appendix X1
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.2.1 Exception—SI units are used in Fig. 6.
- Standard12 pagesEnglish language
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice provides a guide to any individual, group, agency, or code body on the methods of test for truss assemblies fabricated from all types of construction materials. Sample size is generally kept to a minimum to reduce costs. The methods may be used to apply proof loads to an assembly or to test it to failure. Information obtained includes strength and stiffness data, and if assemblies are tested to their ultimate load carrying capacity, the failure method or mechanism can be observed.
SCOPE
1.1 This practice is intended as a guide for use in the testing of truss assemblies fabricated from all types of construction materials. While the practice may be used for the testing of a variety of assemblies, it is primarily intended to be used in the testing of those trusses designed to be spaced at 1.2 m centers or greater. It can be used, but it is not normally intended, for the testing of wood residential trussed rafters. Either proof tests or tests to destruction may be run.
1.2 Limitations—It is not intended that this practice be used for routine quality control testing.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice is intended to be used by parties involved in the testing of floors and roofs of structures either in the field or the laboratory. Tests are either proof tests or tests to failure, and are applicable to all construction materials. The practice is not intended for use in routine quality control testing of individual building elements or constructions.
SCOPE
1.1 This practice covers static load testing of floors and low slope roofs (roofs having a slope of less than 1 in 12) under actual or simulated service conditions, and is applicable to typical elements or sections of structures fabricated for test or to actual existing building components. This practice is intended for use in determining the strength and stiffness of elements or sections of floors and roofs of buildings under gravity loads, as well as in checking the design, materials, connections, and the quality of the fabrication of such building constructions.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SCOPE
1.1 This practice describes methods for evaluating the shear capacity of a typical section of a framed wall, supported on a rigid foundation and having load applied in the plane of the wall along the edge opposite the rigid support and in a direction parallel to it. The objective is to provide a determination of the shear stiffness and strength of any structural light-frame wall configuration to be used as a shear-wall on a rigid support.
1.2 Limitations—This practice is not intended to be used as a basis for classifying sheathing shear capacity or as an evaluation of combined flexure and shear resulting from the wall being loaded on a flexible foundation.
1.2.1 The effect of sheathing variations is assessed by holding all other variables constant. Permitted variations in framing configuration and boundary conditions, however, require accurate documentation of the test setup to validate across-study comparisons of sheathing contribution to wall shear capacity.Note 1—A wall tested on a flexible foundation is evaluated by comparing shear stiffness and strength results to those of an identical wall tested on a rigid foundation, following this practice. However, no methods are given for the measurement of wall bending displacements or assessment of stress distribution resulting from foundation flexure. Any extrapolation of wall racking behavior from the foundation conditions specified by this practice to flexible conditions shall be done with the support of a comparative test on a representative foundation.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
These test methods are intended to measure the performance of vertical elements of the lateral force resisting system subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the specimens.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
Framed floor and roof systems are tested by this test method for static shear capacity. This test method will help determine structural diaphragm properties needed for design purposes.
SCOPE
1.1 This test method covers procedures designed (1) to evaluate the static shear capacity of a typical segment of a framed diaphragm under simulated loading conditions, and (2) to provide a determination of the stiffness of the construction and its connections. A diaphragm construction is an assembly of materials designed to transmit shear forces in the plane of the construction.
1.2 No effort has been made to specify the test apparatus, as there are a number that can be used as long as the needs of the testing agency are met. If round-robin testing is to be conducted, test apparatus and testing procedures shall be mutually agreed upon in advance by the participants.
1.3 The text of this standard contains notes and footnotes that provide explanatory information and are not requirements of the standard. Notes and footnotes in tables and figures are requirements of this standard.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
This practice provides a standard procedure for reporting data and results of structural tests used for building constructions, elements, corrections, and assemblies. It enumerates and discusses the report sections required to report data from test methods and practices. The written reports will describe the products tested, method of testing, and results.
SCOPE
1.1 This practice covers general use in reporting structural performance tests of building constructions, elements, connections, and assemblies. A comprehensive report describing the conditions under which the structural data were recorded will enable other workers to reproduce the test methods and, as nearly as possible, the results for each material or assembly, and to reconcile differences that might be found in tests by others.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SCOPE
1.1 This guide covers the flexural testing of beams and girders under simulated service conditions to determine their structural performance characteristics. Methods following this guide are intended primarily for constructions that may not conform with the relatively simple assumptions upon which well-known flexural theories are based. In some cases, they are also suitable for determining the structural adequacy of the design, materials, connections, and fabrication techniques. The methods are not intended for use in routine quality control tests.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statement, see 7.1.
- Guide3 pagesEnglish language
SIGNIFICANCE AND USE
These test methods are intended to measure the performance of vertical elements of the lateral force resisting system subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the specimens.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
Framed floor and roof systems are tested by this test method for static shear capacity. This test method will help determine structural diaphragm properties needed for design purposes.
SCOPE
1.1 This test method covers procedures designed (1) to evaluate the static shear capacity of a typical segment of a framed diaphragm under simulated loading conditions, and (2) to provide a determination of the stiffness of the construction and its connections. A diaphragm construction is an assembly of materials designed to transmit shear forces in the plane of the construction.
1.2 No effort has been made to specify the test apparatus, as there are a number that can be used as long as the needs of the testing agency are met. If round-robin testing is to be conducted, test apparatus and testing procedures shall be mutually agreed upon in advance by the participants.
1.3 The text of this standard contains notes and footnotes that provide explanatory information and are not requirements of the standard. Notes and footnotes in tables and figures are requirements of this standard.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
Transverse Load—The procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.
Concentrated Load—This concentrated load test shall be used to evaluate surface indentation of structural framing members.
These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Test Method E 455. Impact loading shall be evaluated under Test Methods E 661 or E 695.
SCOPE
1.1 This test method covers the following procedures for determining the structural properties of segments of floor and roof constructions: Section Test Specimens5 Loading6 Deformation Measurements7 Report9 Precision and Bias10 Testing Floors Transverse Load11 Concentrated Load12 Testing Roofs Transverse Load13 Concentrated Load14
1.2 This test method serves to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing or supporting members (floor joist, rafters, and trusses), or both.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.
1.4 This standard is not intended to cover concrete floor slabs.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
These test methods are intended to measure the performance of vertical elements of the lateral force resisting system subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the specimens.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
The procedures outlined will provide data that can be used to evaluate the relative performance of wall, floor, and roof constructions under conditions representative of those sustained in actual service when subjected to impact by a heavy blunt object. See Test Method E 661 for evaluation of floor and roof sheathing and Practice E 73 for evaluation of roof trusses.
The method is intended to be applied to relatively light construction, including, but not limited to, wood floor and roof systems, partitions framed with wood or steel studs, steel floor or roof decking systems, steel siding and wall panels, or thin concrete and masonry walls or slabs and similar assemblies.
SCOPE
1.1 This test method covers the measurement of the relative resistance of wall, floor, and roof construction to impact loading. The test is not applicable to doors.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
p>These test methods are intended to measure the performance of vertical elements of the lateral force resisting system subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the specimens.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard14 pagesEnglish language
- Standard14 pagesEnglish language
SIGNIFICANCE AND USE
These test methods are intended to measure the performance of vertical elements of the lateral force resisting system subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the specimens.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard13 pagesEnglish language
- Standard13 pagesEnglish language
SIGNIFICANCE AND USE
These test methods are intended to measure the performance of walls subjected to earthquake loads. Since these loads are cyclic, the loading process simulates the actions and their effects on the walls.
SCOPE
1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of a wall assembly, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.
1.2 These test methods are intended for wall assemblies constructed from wood or metal framing with solid sheathing or other bracing methods or structural insulated panels.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard13 pagesEnglish language
SIGNIFICANCE AND USE
The procedures described will test the behavior of segments of paneled wall system construction under conditions representative of those encountered in service. Performance criteria based on data from those procedures can verify structural adequacy and service life.
SCOPE
1.1 These test methods cover the procedures for determining the resistance of paneled wall systems subjected to combined lateral loads and axial loads.
1.2 These test methods involve the simultaneous application of transverse (lateral wind) and tensile (wind uplift) loads to paneled wall system assemblies anchored at both ends with hold-down connectors.
1.3 These test methods are suitable for determining the structural adequacy of the design, system, and wall fabrication technique, and are not intended to evaluate the strength capacity of the hold-down connectors.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
This practice provides a guide to any individual, group, agency, or code body on the methods of test for truss assemblies fabricated from all types of construction materials. Sample size is generally kept to a minimum to reduce costs. The methods may be used to apply proof loads to an assembly or to test it to failure. Information obtained includes strength and stiffness data, and if assemblies are tested to their ultimate load carrying capacity, the failure method or mechanism can be observed.
SCOPE
1.1 This practice is intended as a guide for use in the testing of truss assemblies fabricated from all types of construction materials. While the practice may be used for the testing of a variety of assemblies, it is primarily intended to be used in the testing of those trusses designed to be spaced at 1.2 m (48 in.) centers or greater. It can be used, but it is not normally intended, for the testing of wood residential trussed rafters. Either proof tests or tests to destruction may be run.
1.2 Limitations—It is not intended that this practice be used for routine quality control testing.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
- Standard5 pagesEnglish language
SCOPE
1.1 These test methods cover the procedures for determining the resistance of paneled wall systems subjected to combined lateral loads and axial loads.
1.2 These test methods involve the simultaneous application of transverse (lateral wind) and tensile (wind uplift) loads to paneled wall system assemblies anchored at both ends with hold-down connectors.
1.3 These test methods are suitable for determining the structural adequacy of the design, system, and wall fabrication technique, and are not intended to evaluate the strength capacity of the hold-down connectors.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
This practice is intended to be used by parties involved in the testing of floors and roofs of structures either in the field or the laboratory. Tests are either proof tests or tests to failure, and are applicable to all construction materials. The practice is not intended for use in routine quality control testing of individual building elements or constructions.
SCOPE
1.1 This practice covers static load testing of floors and low slope roofs (roofs having a slope of less than 1 in 12) under actual or simulated service conditions, and is applicable to typical elements or sections of structures fabricated for test or to actual existing building components. This practice is intended for use in determining the strength and stiffness of elements or sections of floors and roofs of buildings under gravity loads, as well as in checking the design, materials, connections, and the quality of the fabrication of such building constructions.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
SIPs are used as roof, wall, and floor components in building structures. The structural performance properties need to be determined for design purposes.
SCOPE
1.1 These test methods cover procedures for determining strength properties under specified loads for rigid-faced structural insulated panels. These test methods are appropriate for structural insulated panels with rigid facings having a minimum thickness of 4 mm (0.16 in.) and an insulating core with a minimum thickness of 38 mm (1.5 in.). These specified loads include:
1.1.1 Transverse loads,
1.1.2 Axial loads,
1.1.3 Shear loads,
1.1.4 Diaphragm loads,
1.1.5 Uplift loads,
1.1.6 Long Term loads
1.1.7 Impact loads, and
1.1.8 Concentrated loads.
1.2 Structural insulated panels are intended to resist structural loads in permanent building structures.
1.3 These test methods are not intended for quality control purposes and do not evaluate the individual components of the structural insulated panels.
1.4 These test methods are not intended to measure dimensional stability.
1.5 The text of this standard references notes and footnotes, excluding tables and figures, which provide explanatory information. These notes and footnotes shall not be considered requirements of the standard.
1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
Frequently Asked Questions
E06.11 is a Technical Committee within ASTM International. It is named "Horizontal and Vertical Structures/Structural Performance of Completed Structures". This committee has published 80 standards.
E06.11 develops ASTM standards in the area of Information technology. Currently, there are 80 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.