Standard Specification for Trichloroethylene, Technical and Vapor-Degreasing Grade

SCOPE
1.1 This specification covers technical and vapor degreasing grade trichloroethylene.
Note 1--Practices D3844 and D4276, and MNL2 provide additional important information on vapor degreasing and solvent properties.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Dec-2000
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D4080-96 - Standard Specification for Trichloroethylene, Technical and Vapor-Degreasing Grade
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or
withdrawn. Contact ASTM International (www.astm.org) for the latest information.
Designation: D 4080 – 96
AMERICAN SOCIETY FOR TESTING AND MATERIALS
100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
Standard Specification for
1
Trichloroethylene, Technical and Vapor-Degreasing Grade
This standard is issued under the fixed designation D 4080; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
TABLE 1 Physical Properties
1. Scope
Test
1.1 This specification covers technical and vapor degreasing
Property Specification
Method
grade trichloroethylene.
Specific gravity, 25/25°C 1.450 to 1.460 D 2111
2
Distillation range (760 mm D 1078
NOTE 1—Practices D 3844 and D 4276, and MNL2 provide additional
Hg)
important information on vapor degreasing and solvent properties.
Initial boiling point,° C, 85.0
min
2. Referenced Documents
Dry point, °C, max 90.0
Acidity (as HCl), weight, %, 0.0005 D 2989
2.1 ASTM Standards:
max
D 1078 Test Method for Distillation Range of Volatile
Alkalinity (as NaOH), 0.010 D 2989
3
Organic Liquids
weight, %, max
Water, weight, %, max 0.010 D 3401
D 2108 Test Method for Color of Halogenated Organic Sol
Appearance clear and free from D 3741
4
vents and Their Admixtures (Platinum-Cobalt Scale)
suspended matter
D 2109 Test Methods for Nonvolatile Matter in Haloge-
Color, Pt-Co, max 20 D 2108

4
Halide (as Cl ), weight, 0.0005 D 2988
nated Organic Solvents and Their Admixtures
%, max
D 2111 Test Methods for Specific Gravity of Halogenated
Nonvolatile residue, 0.0050 D 2109
4
Organic Solvents and Their Admixtures weight, %, max
Acid acceptance (as 0.160 D 2942
D 2942 Test Method for Total Acid Acceptance of Haloge-
NaOH), weight, %,
4
nated Organic Solvents (Nonreflux Methods)
min
D 2988 Test Method for Water-Soluble Halide Ion in Halo-
4
genated Organic Solvents and Their Admixtures
2.2 Other Document:
D 2989 Test Method for Acidity-Alkalinity of Halogenated
49 CFR 100 to 199 Department of Transportation Hazard-
4
Organic Solvents a
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.