Standard Test Method for Nonvolatile Ultraviolet (UV) Absorbing Extractables from Microwave Susceptors

ABSTRACT
This test method establishes the apparatuses required, the standard procedures, and associated calculations involved in the determination of relatively polar nonvolatile ultraviolet (UV) absorbing extractable components that may migrate from microwave susceptor packaging into food simulants, such as corn oil and Miglyol 812. This test method has been collaboratively studied using bilaminate susceptors constructed of paperboard, adhesive, and a layer of polyethylene terephthalate polymer (PETE) susceptor.
SCOPE
1.1 This test method covers the determination of nonpolar and relatively polar ultraviolet (UV) absorbing components that may migrate from microwave susceptor packaging into food simulants, such as corn oil and Miglyol 812.  
1.2 This test method has been collaboratively studied using bilaminate susceptors constructed of paperboard, adhesive, and a layer of polyethylene terephthalate polymer (PETE) susceptor. Adhesive and PETE related compounds were quantitated using this test method.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given in 4.3.2.3.

General Information

Status
Historical
Publication Date
31-Mar-2014
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F1349-08(2014) - Standard Test Method for Nonvolatile Ultraviolet (UV) Absorbing Extractables from Microwave Susceptors
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1349 −08 (Reapproved 2014)
Standard Test Method for
Nonvolatile Ultraviolet (UV) Absorbing Extractables from
1
Microwave Susceptors
This standard is issued under the fixed designation F1349; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.2 High-Pressure Liquid Chromatograph (HPLC), consist-
ing of:
1.1 This test method covers the determination of nonpolar
3.2.1 Pump, capable of 1.5 mL/min with flow precision
and relatively polar ultraviolet (UV) absorbing components
62%.
that may migrate from microwave susceptor packaging into
3.2.2 Injector, loop-type, equipped with 20-µL loop.
food simulants, such as corn oil and Miglyol 812.
3.2.3 Guard Column, C , 5 µm.
8
1.2 This test method has been collaboratively studied using
3.2.4 Analytical Column, C , 5 µm, 250 by 4.6 mm.
8
bilaminatesusceptorsconstructedofpaperboard,adhesive,and
3.2.5 Detector-UV Absorbance, set for 254 nm. Adjust
a layer of polyethylene terephthalate polymer (PETE) suscep-
sensitivity to give a 70 to 100 % of full scale peak for the 5-
tor. Adhesive and PETE related compounds were quantitated
ppm dimethylterephthalate DMT standard.
using this test method.
3.2.6 Gradient Program, 4 to 60 % Mobile Phase B in 8
min; 60 to 70 % B in 9 min; 70 to 100 % B in 7 min; 100 % B
1.3 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this for 11 min; 100 to 4 % B in 5 min; 4 % B for minimum of 5
min. Where Mobile Phase A (v/v) is 85 + 15 + 0.25 %
standard.
water:acetonitrile:acetic acid, and Mobile Phase B (v/v)is
1.4 This standard does not purport to address all of the
15 + 85 % water:acetonitrile.
safety concerns, if any, associated with its use. It is the
3.2.7 Peak Area Integration System—Initialize data acqui-
responsibility of the user of this standard to establish appro-
sition or integration system, or both, from 5 to 35 min during
priate safety and health practices and determine the applica-
the separation.
bility of regulatory limitations prior to use. Specific warning
statements are given in 4.3.2.3.
3.3 Hexane, LC/UV grade.
3.4 Acetonitrile, LC/UV grade.
2. Referenced Documents
2
3.5 Corn Oil—Obtain corn oil that is as pure and fresh as
2.1 ASTM Standards:
possible to minimize peaks in nonvolatiles extractables chro-
F874 Test Method for Temperature Measurement and Pro-
matogram. Alternatively, Miglyol 812 (a fractionated coconut
filing for Microwave Susceptors
oil)orsyntheticfatsimulantHB307canbeusedasasubstitute
F1317 Test Method for Calibration of Microwave Ovens
for corn oil.
3. Apparatus and Reagents
3.6 Dimethylacetamide (DMAC), LC/UV grade.
3.1 Microwave Oven, 700 6 35 W, calibrated. Refer to Test
3.7 Conical Bottom Test Tubes, 50 mL, graduated.
Method F1317.
3.8 Bishydroxyethyleneterephthalate (BHET).
3.9 Diethylterephthalate (DET).
1
This test method is under the jurisdiction ofASTM Committee F02 on Flexible
Barrier Packaging and is the direct responsibility of Subcommittee F02.15 on
3.10 Dimethylterephthalate (DMT).
Chemical/Safety Properties.
Current edition approved April 1, 2014. Published April 2014. Originally 3.11 Fluoroptic Thermometry System.
approved in 1991. Last previous edition approved in 2008 as F1349 – 08. DOI:
3.12 Temperature Probes, four, high temperature.
10.1520/F1349-08R14.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
3.13 Glass Beads, 3 to 4 mm, clean thoroughly by rinsing
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
with methylene chloride followed by soaking for 30 min in
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. acetonitrile. Dry thoroughly before using.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1349−08 (2014)
1
NOTE 1—The ⁄16-in. (1.6-mm) diameter hole is for a Luxtron MIW
temperature sensing probe. Number of holes and location may vary by
application.
FIG. 1Collar Section of Waldorf Polytetrafluoroethylene Micro-
wave Nonvolatile Extraction Cell
NOTE 1—Relieve thread at bottom. Collar must seal to bottom of cap.
FIG. 2Cap Section of Waldorf Polytetrafluorethylene Nonvolatile
Extraction Cell
2

---------------------- Page: 2 ----------------------
F1349−08 (2014)
FIG. 3 Suggested Modifications to Waldorf Cell
3.14 Recommended Microwave Nonvolatile Extraction activesusceptormaterial.Thesusceptorshouldbecuttofitinto
3
Cell—Waldorf Polytetrafluoroethylene cell. (See Figs. 1-3). a Wal
...