Standard Specification for Self-Supported Spray Applied Cellulosic Thermal Insulation

SCOPE
1.1 The specification covers the physical properties of self-supported spray applied cellulosic fibers intended for use as thermal insulation or an acoustical absorbent material, or both.
1.2 This specification covers chemically treated cellulosic materials intended for pneumatic applications where temperatures do not exceed 82.2°C (180°F) and where temperatures will routinely remain below 65.6°C (150°F).
1.2.1 Type I Material applied with liquid adhesive and suitable for either exposed or enclosed applications.
1.2.2 Type II Materials containing a dry adhesive that is activated by water during installation and intended only for enclosed or covered applications.
1.3 This is a material specification only and is not intended to deal with methods of application that are supplied by the manufacturer.
1.4 The values stated in SI units are to be regarded as standard. The inch-pound units given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Nov-2006
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1149-06 - Standard Specification for Self-Supported Spray Applied Cellulosic Thermal Insulation
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

Designation: C 1149 – 06
Standard Specification for
1
Self-Supported Spray Applied Cellulosic Thermal Insulation
This standard is issued under the fixed designation C 1149; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope C 518 Test Method for Steady-State Thermal Transmission
Properties by Means of the Heat Flow Meter Apparatus
1.1 The specification covers the physical properties of
C 739 Specification for Cellulosic Fiber Loose-FillThermal
self-supported spray applied cellulosic fibers intended for use
Insulation
as thermal insulation or an acoustical absorbent material, or
C 1363 Test Method for Thermal Performance of Building
both.
Materials and Envelope Assemblies by Means of a Hot
1.2 This specification covers chemically treated cellulosic
Box Apparatus
materials intended for pneumatic applications where tempera-
E84 Test Method for Surface Burning Characteristics of
tures do not exceed 82.2°C (180°F) and where temperatures
Building Materials
will routinely remain below 65.6°C (150°F).
E 605 Test Methods for Thickness and Density of Sprayed
1.2.1 Type I—Material applied with liquid adhesive and
Fire-Resistive Material (SFRM) Applied to Structural
suitable for either exposed or enclosed applications.
Members
1.2.2 Type II—Materials containing a dry adhesive that is
E 736 Test Method for Cohesion/Adhesion of Sprayed Fire-
activated by water during installation and intended only for
Resistive Materials Applied to Structural Members
enclosed or covered applications.
E 759 Test Method for Effect of Deflection on Sprayed
1.3 This is a material specification only and is not intended
Fire-Resistive Material Applied to Structural Members
to deal with methods of application that are supplied by the
E 859 Test Method for Air Erosion of Sprayed Fire-
manufacturer.
Resistive Materials (SFRMs) Applied to Structural Mem-
1.4 The values stated in SI units are to be regarded as
bers
standard. The inch-pound units given in parentheses are for
information only.
3. Terminology
1.5 This standard does not purport to address all of the
3.1 Definitions—Definitions in Terminology C 168 shall
safety concerns, if any, associated with its use. It is the
apply in this specification.
responsibility of the user of this standard to establish appro-
3.2 Definitions of Terms Specific to This Standard:
priate safety and health practices and determine the applica-
3.2.1 constant mass—no change in successive weighings in
bility of regulatory limitations prior to use.
excess of 0.5 % of specimen mass taken at 4-h intervals unless
2. Referenced Documents otherwise specified. Specimen should not be always increasing
2 in weight or decreasing in weight.
2.1 ASTM Standards:
3.2.2 cured—the state of the finished product after it has
C 168 Terminology Relating to Thermal Insulation
achieved constant mass.
C 177 Test Method for Steady-State Heat Flux Measure-
3.2.3 curing—the process in which the liquid vehicle is
ments and Thermal Transmission Properties by Means of
removed. Normally achieved in ambient building conditions
the Guarded-Hot-Plate Apparatus
with forced air convection to hasten the evaporation process.
3.2.4 prepared sample—samples prepared in accordance
1
This specification is under the jurisdiction of ASTM Committee C16 on
with Section 5 and cured to constant mass prior to conducting
Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on
thespecifictests.Thepreparedsamples,afterreachingconstant
Blanket and Loose Fill Insulation.
mass, as defined in 3.2.1, shall have a density within 610 % of
Current edition approved Dec. 1, 2006. Published December 2006. Originally
the manufacturer’s recommended design density.
approved in 1990. Last previous edition approved in 2002 as C 1149-02.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
3.2.5 self supporting—a product that can be tested by the
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
criteria imposed by this specification and that will require no
Standards volume information, refer to the standard’s Document Summary page on
support other than itself or the substrate to which it is attached.
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1149–06
3
3.2.6 specimen—definition of specimen as used in this 4.11 Flame Resistance Permanency:
specification shall be the same as that for prepared sample in 4.11.1 The importance of an insulation’s product to main-
3.2.4. tain its fire retardant characteristics is recognized.Atask group
iscurrentlystudyingmethodstoascertainifthereisalongterm
3.2.7 sprayed fiber—chemicallytreatedcellulosic
...