ASTM C1405-23
(Specification)Standard Specification for Glazed Brick (Single Fired, Brick Units)
Standard Specification for Glazed Brick (Single Fired, Brick Units)
ABSTRACT
This specification deals with the standards for bricks, having a ceramic glaze finish fused to the body during the same process as the unit body firing, that are intended for use in masonry. These products are also proposed for use in supplying structural or facing components. This specification, however, doest not cover double-fired glazed brick. The bricks shall be available in two grades: grade S (standard) and grade SS (select sized). Two types and classes of bricks are also covered: type I (single-faced units) and type II (two-faced units); and class exterior and class interior. The glazed bricks shall also conform to the physical properties such as durability, strength and absorption requirements and freezing and thawing requirements.
SCOPE
1.1 This specification covers brick, having a ceramic glaze finish fused to the body during the same process as the unit body firing, that are intended for use in masonry and supplying structural or facing components, or both, to the structure. This specification does not cover double-fired glazed brick. Some double-fired decorative glazes have physical properties, which vary from those of single-fired glazes due to the lower temperatures used in applying the decorative coating.
1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or nonconformance to the property requirements of this specification is beyond the scope of this specification.
1.3 Glazed brick are prismatic units available in a variety of sizes, textures, colors, and shapes. Glazed brick are manufactured from clay, shale, or similar naturally occurring earthy substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment shall develop a fired bond between the particulate constituents to provide the strength and durability requirements of this specification (see Terminology C1232).
1.4 Glazed brick are shaped during manufacture by molding, pressing, or extrusion, and the shaping method is a way to describe the brick.
1.5 Glazed brick are classified into one of two grades, one of two types, one of two classes, and one of three divisions.
1.6 Opacity of the glaze is not required unless specified by the purchaser.
1.7 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: C1405 − 23
Standard Specification for
1
Glazed Brick (Single Fired, Brick Units)
This standard is issued under the fixed designation C1405; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* conversions to SI units that are provided for information only
and are not considered standard.
1.1 This specification covers brick, having a ceramic glaze
1.9 This standard does not purport to address all of the
finish fused to the body during the same process as the unit
body firing, that are intended for use in masonry and supplying safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
structural or facing components, or both, to the structure. This
specification does not cover double-fired glazed brick. Some priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
double-fired decorative glazes have physical properties, which
vary from those of single-fired glazes due to the lower 1.10 This international standard was developed in accor-
temperatures used in applying the decorative coating. dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the
1.2 The property requirements of this specification apply at
Development of International Standards, Guides and Recom-
the time of purchase. The use of results from testing of brick
mendations issued by the World Trade Organization Technical
extracted from masonry structures for determining confor-
Barriers to Trade (TBT) Committee.
mance or nonconformance to the property requirements of this
specification is beyond the scope of this specification.
2. Referenced Documents
1.3 Glazed brick are prismatic units available in a variety of
2
2.1 ASTM Standards:
sizes, textures, colors, and shapes. Glazed brick are manufac-
C67/C67M Test Methods for Sampling and Testing Brick
tured from clay, shale, or similar naturally occurring earthy
and Structural Clay Tile
substances and subjected to a heat treatment at elevated
C1088 Specification for Thin Veneer Brick Units Made
temperatures (firing). The heat treatment shall develop a fired
From Clay or Shale
bond between the particulate constituents to provide the
C1232 Terminology for Masonry
strength and durability requirements of this specification (see
C1895 Test Method for Determination of Mohs Scratch
Terminology C1232).
Hardness
1.4 Glazed brick are shaped during manufacture by
E84 Test Method for Surface Burning Characteristics of
molding, pressing, or extrusion, and the shaping method is a
Building Materials
way to describe the brick.
E2105 Practice for General Techniques of Thermogravimet-
1.5 Glazed brick are classified into one of two grades, one of ric Analysis (TGA) Coupled With Infrared Analysis
two types, one of two classes, and one of three divisions.
(TGA/IR)
1.6 Opacity of the glaze is not required unless specified by 2.2 NFPA Standard:
the purchaser.
NFPA No. 255 Test for Surface Burning Characteristics of
3
Building Materials
1.7 The text of this standard references notes and footnotes
that provide explanatory material. These notes and footnotes 2.3 UL Standard:
(excluding those in tables and figures) shall not be considered UL No. 723 Flammability Studies of Cellular Plastics and
4
as requirements of this standard. Other Building Materials Used for Interior Finishes
1.8 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
This specification is under the jurisdiction of ASTM Committee C15 on Standards volume information, refer to the standard’s Document Summary page on
Manufactured Masonry Units and is the direct responsibility of Subcommittee the ASTM website.
3
C15.02 on Brick and Structural Clay Tile. Available from National Fire Protection Association (NFPA), 1 Batterymarch
Current edition approved March 1, 2023. Published March 2023. Originally Park, Quincy, MA 02169-7471, http://www.nfpa.org.
4
approved in 1998. Last previous edition approved in 2022 as C1405 – 22. DOI: Available from Underwriters Laboratories (UL), 333 Pfingsten Rd.,
10.1520/C1405-23. Northbrook, IL 60062-2096, http://www.ul.com.
*A Summary of Changes section appears at th
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1405 − 22 C1405 − 23
Standard Specification for
1
Glazed Brick (Single Fired, Brick Units)
This standard is issued under the fixed designation C1405; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers brick, having a ceramic glaze finish fused to the body during the same process as the unit body firing,
that are intended for use in masonry and supplying structural or facing components, or both, to the structure. This specification
does not cover double-fired glazed brick. Some double-fired decorative glazes have physical properties, which vary from those of
single-fired glazes due to the lower temperatures used in applying the decorative coating.
1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted
from masonry structures for determining conformance or nonconformance to the property requirements of this specification is
beyond the scope of this specification.
1.3 Glazed brick are prismatic units available in a variety of sizes, textures, colors, and shapes. Glazed brick are manufactured
from clay, shale, or similar naturally occurring earthy substances and subjected to a heat treatment at elevated temperatures (firing).
The heat treatment shall develop a fired bond between the particulate constituents to provide the strength and durability
requirements of this specification (see Terminology C1232).
1.4 Glazed brick are shaped during manufacture by molding, pressing, or extrusion, and the shaping method is a way to describe
the brick.
1.5 Glazed brick are classified into one of two grades, one of two types, one of two classes, and one of three divisions.
1.6 Opacity of the glaze is not required unless specified by the purchaser.
1.7 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of this standard.
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1
This specification is under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.02 on Brick
and Structural Clay Tile.
Current edition approved June 1, 2022March 1, 2023. Published June 2022March 2023. Originally approved in 1998. Last previous edition approved in 20202022 as
C1405 – 20a.C1405 – 22. DOI: 10.1520/C1405-22.10.1520/C1405-23.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1405 − 23
1.10 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C67/C67M Test Methods for Sampling and Testing Brick and Structural Clay Tile
C1088 Specification for Thin Veneer Brick Units Made From Clay or Shale
C1232 Terminology for Masonry
C1895 Test Method for Determination of Mohs Scratch Hardness
E84 Test Method for Surface Burning Characteristics of Building Materials
E2105 Practice for General Techniques of Thermogravimetric Analysis (TGA) Coupled With Infrared Analysis (TGA/IR)
2.2 NFPA Standard:
3
NFPA No. 255 Test for Surface Burning Characteristics of Building Materials
2.3 UL Standard:
4
UL No. 723 Flammability Studies of Cellular Plastics and Other Building Materials Used for Interior Finishes
3. Terminology
3.1 Definitions—Terms used in this specification are defined in accordance with Terminology C
...
Questions, Comments and Discussion