Standard Specification for Arc and Flame Resistant Rainwear

SCOPE
1.1 This specification establishes applicable test methods, minimum physical and thermal performance criteria, a suggested sizing guide, and suggested purchasing information for rainwear for use by workers who may be exposed to thermal hazards of momentary electric arcs and open flames.
1.1.1 This specification does not apply to the electrical contact hazards or electric shock hazards involved with electric arcs.
1.1.2 This specification does not apply to flash fire hazards such as industrial hydrocarbon flash fires or other petrochemical flash fire hazards. 1.2 The objective of this specification is to prescribe fit, function and performance criteria for rainwear that meets a minimum level of thermal and physical performance when exposed to a laboratory-simulated electric arc or flame exposure.
1.3 This specification is not intended to serve as a detailed manufacturing or purchasing specification, but can be referenced in purchase contracts to ensure that minimum performance requirements are met.
1.4 Controlled laboratory tests used to determine compliance with the performance requirements of this specification shall not be deemed as establishing performance levels for all situations to which wearers of this protective clothing may be exposed.
1.5 The in-service care and use of this rainwear is beyond the scope of this specification.
1.6 The values stated in inch-pound units are to be regarded as the standard. The SI units shown in parentheses are for information only.
1.7 The following safety hazards caveat pertains only to Sections 7 and 9, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Mar-2002
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1891-02 - Standard Specification for Arc and Flame Resistant Rainwear
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: F 1891 – 02
Standard Specification for
1
Arc and Flame Resistant Rainwear
This standard is issued under the fixed designation F 1891; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
1.1 This specification establishes applicable test methods, 2.1 ASTM Standards:
2
minimum physical and thermal performance criteria, a sug- D 123 Terminology Relating to Textiles
3
gested sizing guide, and suggested purchasing information for D 751 Test Methods for Coated Fabrics
2
rainwear for use by workers who may be exposed to thermal D 1117 Guide for Evaluating Nonwoven Fabrics
2
hazards of momentary electric arcs and open flames. D 1388 Test Method for Stiffness of Fabrics
3
1.1.1 This specification does not apply to the electrical D 3393 Specification for Coated Fabrics—Waterproofness
contact hazards or electric shock hazards involved with electric D 3776 Test Method for Mass Per Unit Area (Weight) of
4
arcs. Fabric
1.1.2 This specification does not apply to flash fire hazards D 6413 Test Method for Flame Resistance of Textiles (Ver-
4
such as industrial hydrocarbon flash fires or other petrochemi- tical Test)
cal flash fire hazards. F 1958 Test Method for Determining Ignitability of Non-
1.2 The objective of this specification is to prescribe fit, Flame-Resistant Materials for Clothing by the Electric Arc
5
function and performance criteria for rainwear that meets a Exposure Method Using Mannequins
minimum level of thermal and physical performance when F 1959/F 1959M Test Method for Determining the Arc
5
exposed to a laboratory–simulated electric arc or flame expo- Thermal Performance Value of Materials for Clothing
sure. 2.2 Federal Specifications:
1.3 This specification is not intended to serve as a detailed Federal Test Method Standard (FTMS) No. 191A Method
6
manufacturing or purchasing specification, but can be refer- 5903.1
enced in purchase contracts to ensure that minimum perfor- Federal Test Method Standard (FTMS) No. 191A Method
6
mance requirements are met. 5516
1.4 Controlled laboratory tests used to determine compli- Federal Test Method Standard (FTMS) No. CCC-T-191b
6
ance with the performance requirements of this specification Method 5204
shall not be deemed as establishing performance levels for all 2.3 AATCC Standards:
situations to which wearers of this protective clothing may be AATCC Test Method 135 Dimensional Changes Automatic
7
exposed. Home Laundering of Woven and Knitted Fabrics
1.5 The in-service care and use of this rainwear is beyond
3. Terminology
the scope of this specification.
3.1 Definitions:
1.6 The values stated in inch-pound units are to be regarded
as the standard. The SI units shown in parentheses are for 3.1.1 afterflame time, n—the length of time afterflame
continues after the ignition source has been removed.
information only.
1.7 The following safety hazards caveat pertains only to 3.1.1.1 Discussion—For arc testing, the time begins when
the arc current ceases and ends when visible flame ends.
Sections 7 and 9, of this specification: This standard does not
purport to address all of the safety concerns, if any, associated 3.1.2 arc rating, n—the maximum incident energy (E )
1
resistance demonstrated by a material prior to breakopen or at
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and the onset of a second degree burn.
determine the applicability of regulatory limitations prior to
use.
2
Annual Book of ASTM Standards, Vol 07.01.
3
Annual Book of ASTM Standards, Vol 09.02.
4
Annual Book of ASTM Standards, Vol 07.02.
5
Annual Book of ASTM Standards, Vol 10.03.
1 6
This specification is under the jurisdiction of ASTM Committee F18 on Available from Standardization Documents Order Desk, Bldg. 4, Section D,
Electrical Protective Equipment for Workers and is the direct responsibility of 700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
7
Subcommittee F18.65 on Wearing Apparel. AATCC Technical Manual, available from American Association of Textile
Current edition approved Jan. 10, 2002. Published March 2002. Originally Chemists and Colorists, One Davis Dr., PO Box 12215, Research Triangle Park, NC
published as F 1891–98. Last previous edition F 1891–01a. 27709–2215.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F 1891
3.1.2.1 Discussion—When the arc thermal performance burning for at least 5 s, or consumption of at least 25 % of the
value (A
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.