Standard Guide for Selection of Membranes Used in Vegetative Roofing Systems

SIGNIFICANCE AND USE
4.1 This guide provides the general information, procedures, and guidelines for the selection of the waterproofing membrane to create a waterproofing system for a Vegetative (Green) roof.  
4.2 This guide is not all inclusive; this guide is intended to supplement detailed instructions from manufacturers, ASTM Standards, and building code requirements.
SCOPE
1.1 The purpose of this guide is to provide guidance in the selection of a suitable waterproofing membrane within a vegetative roof system. The guide offers various options for reviewing the membrane installation during and upon completion of the installation and prior to the vegetative components being installed. This guide applies to membranes that do or do not require UV protection. For the purpose of this guide, the supporting structure and roof deck are assumed to be mechanically and structurally sound and will accept the weight of the vegetative roof system including the membrane, insulation, and other roofing/waterproofing components including all components related to the vegetative layers as well as the required design loads. Slope to drain at the membrane level is preferred and should be included where possible. Providing a replacement or a re-cover vegetative roofing system on an existing building may require that the support structure be reinforced so that it can safely support the additional weight of the vegetative roof system and also provide the minimum live load capacity required by the building code.  
1.2 Design criteria associated with the vegetative portions of the system are beyond the scope of this guide. Please refer to Guide E2777.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
14-Jul-2017
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Guide
ASTM D8014-17 - Standard Guide for Selection of Membranes Used in Vegetative Roofing Systems
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:D8014 −17
Standard Guide for
Selection of Membranes Used in Vegetative Roofing
1
Systems
This standard is issued under the fixed designation D8014; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 The purpose of this guide is to provide guidance in the
D1079 Terminology Relating to Roofing and Waterproofing
selection of a suitable waterproofing membrane within a
D5957 Guide for Flood Testing Horizontal Waterproofing
vegetative roof system. The guide offers various options for
Installations
reviewing the membrane installation during and upon comple-
D7877 Guide for Electronic Methods for Detecting and
tion of the installation and prior to the vegetative components
Locating Leaks in Waterproof Membranes
being installed. This guide applies to membranes that do or do
E2777 Guide for Vegetative (Green) Roof Systems
not require UV protection. For the purpose of this guide, the
3
2.2 ANSI/SPRI Standards:
supporting structure and roof deck are assumed to be mechani-
ANSI/SPRI VR-1 Procedure for Investigating Resistance to
cally and structurally sound and will accept the weight of the
Root Penetration on Vegetative Roofs
vegetativeroofsystemincludingthemembrane,insulation,and
2.3 Other Standards and Documents:
other roofing/waterproofing components including all compo-
FLL Guidelines for the Planning, Construction and Mainte-
nents related to the vegetative layers as well as the required
nance of Green Roofing – Green Roofing Guideline Sec-
design loads. Slope to drain at the membrane level is preferred
tion 6.3 Protection Against Damage to the Waterproofing
and should be included where possible. Providing a replace-
/ Root-resistant Membranes FLLProcedure for Investigat-
ment or a re-cover vegetative roofing system on an existing
ing Resistance to Root Penetration of Roof Membranes
building may require that the support structure be reinforced so
4
and Protective Layers for Green Roofing
thatitcansafelysupporttheadditionalweightofthevegetative
roof system and also provide the minimum live load capacity
3. Terminology
required by the building code.
3.1 Definitions—For definitions of terms used in this guide,
1.2 Design criteria associated with the vegetative portions see Terminology D1079.
of the system are beyond the scope of this guide. Please refer
4. Significance and Use
to Guide E2777.
4.1 This guide provides the general information,
1.3 This standard does not purport to address all of the
procedures, and guidelines for the selection of the waterproof-
safety concerns, if any, associated with its use. It is the
ing membrane to create a waterproofing system for a Vegeta-
responsibility of the user of this standard to establish appro-
tive (Green) roof.
priate safety and health practices and determine the applica-
4.2 This guide is not all inclusive; this guide is intended to
bility of regulatory limitations prior to use.
supplement detailed instructions from manufacturers, ASTM
1.4 This international standard was developed in accor-
Standards, and building code requirements.
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the
5. Roof Design Classifications
Development of International Standards, Guides and Recom-
5.1 Types of Constructions or Applications:
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
1
This guide is under the jurisdiction of ASTM Committee D08 on Roofing and the ASTM website.
3
Waterproofing and is the direct responsibility of Subcommittee D08.24 on Sustain- Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
ability. 4th Floor, New York, NY 10036, http://www.ansi.org.
4
Current edition approved July 15, 2017. Published August 2017. DOI: 10.1520/ Available from Forschungsgesellschaft Landschaftsentwicklung Landschafts-
D8014-17. bau e.V. (FLL), Friedensplatz 4, 53111 Bonn, Germany, www.fll.de.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D8014−17
5.1.1 New—A vegetative roof can be integrated
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.