Standard Test Method for Volatile Oil in Rosin

SIGNIFICANCE AND USE
Rosin and similar materials such as rosin derivatives often contain volatile material derived from the raw material used or formed as a result of the processing of the rosin. This volatile material can have a significant effect on the physical and chemical properties of the rosin and so a standard method for its determination is required.
SCOPE
1.1 This test method covers the determination of the volatile oil content of rosin or similar material. The oil may consist of naturally occurring terpene oil, such as heavy fractions of turpentine, resulting from incomplete distillation in the processing of the rosin, or of foreign nonterpene oil resulting from incomplete removal of mineral or coal-tar solvent used to extract the rosin from wood or still wastes. In certain cases the volatile oil could consist of decarboxylated rosin formed during the processing of the rosin.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-May-2004
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D889-99(2004) - Standard Test Method for Volatile Oil in Rosin
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D889–99(Reapproved2004)
Standard Test Method for
Volatile Oil in Rosin
This standard is issued under the fixed designation D 889; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 4.2 Trap (Fig. 2), designed so as to overcome the tendency
for droplets of oil to remain below the surface of the water, due
1.1 This test method covers the determination of the volatile
tothegreaterviscosityofthevolatileoilsrecoveredfromrosin,
oil content of rosin or similar material. The oil may consist of
and thus be returned to the flask (Note 1). The trap shall be
naturally occurring terpene oil, such as heavy fractions of
fitted with 24/40 standard-taper ground joints to provide tight
turpentine, resulting from incomplete distillation in the pro-
connections with the flask and condenser, in order to avoid
cessing of the rosin, or of foreign nonterpene oil resulting from
vapor loss.
incomplete removal of mineral or coal-tar solvent used to
extract the rosin from wood or still wastes. In certain cases the
NOTE 1—This trap is a modification of the original Clevenger trap used
volatile oil could consist of decarboxylated rosin formed
to recover oils lighter than water. In that trap the oil and water condensate
drop directly into the graduated part of the trap. Due to the viscous
during the processing of the rosin.
character, density, and surface tension of the oils recovered from rosin,
1.2 The values stated in SI units are to be regarded as the
cylindrical columns of oil were formed below the surface of the water in
standard. The values given in parentheses are for information
the graduated section of the trap, which were not penetrated by the water
only.
condensedimmediatelythereafter.Thisresultedinalternatecolumnsofoil
1.3 This standard does not purport to address all of the
and water in the graduated section. These were returned to the distilling
safety concerns, if any, associated with its use. It is the
flask in the same order as they occurred, through the side arm of the trap.
responsibility of the user of this standard to establish appro- As this condition continued indefinitely, it was impossible to completely
remove all the oil from the rosin. By raising the opening of the side arm
priate safety and health practices and determine the applica-
of the trap to the position shown, to bring the surface of the liquid into the
bility of regulatory limitations prior to use.
wide part of the trap above the narrow graduated section, the oil is
collected in a thinner film that can be penetrated readily by the droplets of
2. Referenced Documents
water falling from the end of the condenser, and only the water is thus
2.1 ASTM Standards:
collected in the narrow graduated section.At the end of the test, the oil is
D 233 Test Methods of Sampling and Testing Turpentine
slowly brought down into the graduated section and its volume read. The
E 1 Specification for ASTM Thermometers system or apparatus loss amounts to not more than 0.1 mL of oil.
4.3 Condenser, straight-tube, 300-mm, water-jacketed re-
3. Significance and Use
flux type, with a 24/40 standard-taper ground joint for connec-
3.1 Rosin and similar materials such as rosin derivatives
tion with the trap.
often contain volatile material derived from the raw material
4.4 Heat Source—An oil bath containing high-temperature-
used or formed as a result of the processing of the rosin. This
resistant oil, or an electric heater of the mantle type in which
volatile material can have a significant effect on the physical
theheatingelementsareencasedinaglassclothmantleofsuch
and chemical properties of the rosin and so a standard method
shape as to partially or completely surround the flask being
for its determination is required.
heated.
4.5 Thermometer, having a range from 30 to 200 °C,ASTM
4. Apparatus
16C or equivalent (see Specification E 1).
4.1 Flask,500-mLround-bottomhavingathermometerwell
4.6 Glass Beads.
and a 24/40 standard-taper ground joint for connection with the
trap (see Fig. 1).
5. Procedure
5.1 Place 50 g of the crushed sample in the flask, add 125
mLof a glycerin-water solution (4 + 1), add a few glass beads,
This test method is under the jurisdiction of ASTM Committee D01 on Paint
and Related Coatings, Materials, andApplications and is the direct responsibility of
insert an ebullition tube, and connect the flask with the trap.
Subcommittee D01.34 on Naval Stores.
Fill the trap (Fig. 2) with water through the top opening until
Current edition approved June 1, 2
...

Questions, Comments and Discussion