ASTM E1317-08a
(Test Method)Standard Test Method for Flammability of Marine Surface Finishes
Standard Test Method for Flammability of Marine Surface Finishes
SIGNIFICANCE AND USE
This test method provides a means for evaluation of the flammable performance of surface finish materials used in constructing and outfitting ships.
A specimen of the surface finish of concern is mounted on the support material contemplated for use and subjected to a controlled significant radiant-flux exposure.
All specimens are tested while mounted in a vertical plane.
The following surfaces are exposed to test:
Bulkhead specimens having surface veneers, fabrics, or painted finishes are tested on one or both exposed sides.
Ceiling finish materials shall be tested on the lower exposed surface.
For ceiling finish materials which are perforated and air backed, tests also shall be conducted on the back (upper) surface of the material.
Deck finish and flooring materials are tested on the upper exposed surface.
Protective membranes or finishes on insulation materials are tested on the air-exposed face or faces.
This test method provides fire properties that relate to the flammability of the specimens tested. These include ignitability, heat exposure for continued burning, critical flux at extinguishment, and heat-release behavior under varying flux-exposure conditions applied.
This test method does not provide:
Full information on fire properties of surface-finish materials supported by backing materials other than those tested.
Full information on surface-finish materials when used in other thicknesses than those tested.
Methods for using the fire property measurements as a measure for classifying the fire risk or hazard of the specimens tested.
SCOPE
1.1 This fire-test-response standard covers a procedure for measuring fire properties associated with flammable behavior of surface finishes used on noncombustible substrates aboard ship (Note 1). In particular, these include surface finishes intended for use in ship construction such as deck surfacing materials, bulkhead and ceiling veneers including any adhesives used to fasten the veneers to the bulkheads and ceilings, paints, and exposed treatment of insulating materials.
Note 1—This test method has been prepared to closely follow the test procedure of IMO Resolution A.653(16) (1). Optional provisions not applicable to the domestic use of this test method have been deleted.
1.2 Tests performed according to this test method are intended to yield fire properties that, when appropriately interpreted, are potentially useful to select materials and surface treatments that will limit the rapid growth and spread of fire.
1.3 This test method requires a specific range of specimen radiant thermal exposure for measuring fire properties.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation:E1317–08a
Standard Test Method for
1
Flammability of Marine Surface Finishes
This standard is issued under the fixed designation E1317; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
3
1.1 This fire-test-response standard covers a procedure for 2.1 ASTM Standards:
measuring fire properties associated with flammable behavior E84 Test Method for Surface Burning Characteristics of
of surface finishes used on noncombustible substrates aboard Building Materials
ship (Note 1). In particular, these include surface finishes E162 Test Method for Surface Flammability of Materials
intended for use in ship construction such as deck surfacing Using a Radiant Heat Energy Source
materials, bulkhead and ceiling veneers including any adhe- E176 Terminology of Fire Standards
sives used to fasten the veneers to the bulkheads and ceilings, E 286 Method ofTest for Surface Flammability of Building
4
paints, and exposed treatment of insulating materials. Materials Using an 8-ft (2.44-m) Tunnel Furnace
E648 Test Method for Critical Radiant Flux of Floor-
NOTE 1—This test method has been prepared to closely follow the test
2 Covering Systems Using a Radiant Heat Energy Source
procedure of IMO Resolution A.653(16) (1). Optional provisions not
E970 Test Method for Critical Radiant Flux of Exposed
applicable to the domestic use of this test method have been deleted.
AtticFloorInsulationUsingaRadiantHeatEnergySource
1.2 Tests performed according to this test method are
E1321 Test Method for Determining Material Ignition and
intended to yield fire properties that, when appropriately
Flame Spread Properties
interpreted, are potentially useful to select materials and
2.2 Code of Federal Regulations (CFR):
surfacetreatmentsthatwilllimittherapidgrowthandspreadof
5
CFR Title 46, Part 164.009, Noncombustible Materials
fire.
2.3 ASTM Adjuncts:ASTM
1.3 This test method requires a specific range of specimen
Detailed drawings (19), construction information, and parts
radiant thermal exposure for measuring fire properties.
6
list (Adjunct to E1317)
1.4 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
3. Terminology
standard.
3.1 Definitions—For definitions of general terms used in
1.5 This standard is used to measure and describe the
this test method, refer to Terminology E176.
response of materials, products, or assemblies to heat and
3.2 Definitions of Terms Specific to This Standard:
flame under controlled conditions, but does not by itself
3.2.1 compensating thermocouple, n—a thermocouple for
incorporate all factors required for fire hazard or fire risk
the purpose of generating an electrical signal representing
assessment of the materials, products, or assemblies under
long-term changes in the stack metal temperatures wherein a
actual fire conditions.
fraction of the signal generated is subtracted from the signal
1.6 This standard does not purport to address all of the
developed by the stack-gas thermocouples.
safety concerns, if any, associated with its use. It is the
3.2.2 critical flux at extinguishment, n— a flux level at the
responsibility of the user of this standard to establish appro-
specimen surface corresponding to the distance of farthest
priate safety and health practices and determine the applica-
advance and subsequent self-extinguishment of the flame on
bility of regulatory limitations prior to use. For specific hazard
the centerline of a specimen.
statements, see Section 7.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
This test method is under the jurisdiction of ASTM Committee E05 on Fire Standards volume information, refer to the standard’s Document Summary page on
Standards and is the direct responsibility of Subcommittee E05.22 on Surface the ASTM website.
4
Burning. Discontinued; see 1992 Annual Book of ASTM Standards , Vol 04.07.
5
Current edition approved April 1, 2008. Published April 2008. Originally Available from Superintendent of Documents, U.S. Government Printing
approved in 1990. Last previous edition approved in 2008 as E1317–08. Office, Washington, DC 20402.
2 6
The boldface numbers in parentheses refer to a list of references at the end of Detailed drawings are available from ASTM Headquarters. Request
this standard.
ADJE1317.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:E1317–08 Designation:E1317–08a
Standard Test Method for
1
Flammability of Marine Surface Finishes
This standard is issued under the fixed designation E1317; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This fire-test-response standard covers a procedure for measuring fire properties associated with flammable behavior of
surface finishes used on noncombustible substrates aboard ship (Note 1). In particular, these include surface finishes intended for
use in ship construction such as deck surfacing materials, bulkhead and ceiling veneers including any adhesives used to fasten the
veneers to the bulkheads and ceilings, paints, and exposed treatment of insulating materials.
2
NOTE 1—ThistestmethodhasbeenpreparedtocloselyfollowthetestprocedureofIMOResolutionA.653(16)(1). Optionalprovisionsnotapplicable
to the domestic use of this test method have been deleted.
1.2 Tests performed according to this test method are intended to yield fire properties that, when appropriately interpreted, are
potentially useful to select materials and surface treatments that will limit the rapid growth and spread of fire.
1.3 This test method requires a specific range of specimen radiant thermal exposure for measuring fire properties.
1.4
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under
controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials,
products, or assemblies under actual fire conditions.
1.5
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. For specific hazard statements, see Section 7.
2. Referenced Documents
3
2.1 ASTM Standards:
E84 Test Method for Surface Burning Characteristics of Building Materials
E162 Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source
E176 Terminology of Fire Standards
4
E 286 Method of Test for Surface Flammability of Building Materials Using an 8-ft (2.44-m) Tunnel Furnace
E648 Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
E970 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
E1321 Test Method for Determining Material Ignition and Flame Spread Properties
2.2 Code of Federal Regulations (CFR):
5
CFR Title 46, Part 164.009, Noncombustible Materials
2.3 ASTM Adjuncts:ASTM
6
Detailed drawings (19), construction information, and parts list (Adjunct to E1317)
3. Terminology
3.1 Definitions—For definitions of general terms used in this test method, refer to Terminology E176.
3.2 Definitions of Terms Specific to This Standard:
1
This test method is under the jurisdiction of ASTM Committee E05 on Fire Standards and is the direct responsibility of Subcommittee E05.22 on Surface Burning.
Current edition approved Jan.April 1, 2008. Published JanuaryApril 2008. Originally approved in 1990. Last previous edition approved in 20022008 as
E1317–97a(2002).E1317–08.
2
The boldface numbers in parentheses refer to a list of references at the end of this standard.
3
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
4
Discontinued; see 1992 Annual Book of ASTM Standards , Vol 04.07.
5
Available from Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.
6
Detailed drawings are available from ASTM Headquarters. Request ADJE1317.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
E1317–08a
3.2.1 compensating thermocouple, n—a thermocouple for the purpose of generating an electrical signal representing long-term
changes in the sta
...
Questions, Comments and Discussion