ASTM F922-01(2006)
(Test Method)Standard Test Method for Motor Life Evaluation of an Electric Motorized Nozzle
Standard Test Method for Motor Life Evaluation of an Electric Motorized Nozzle
SIGNIFICANCE AND USE
The test results provide an indication of the motor life of an electric motorized nozzle. End of motor life will be judged in accordance with Section 3.
SCOPE
1.1 This test method covers the motorized nozzle used with household or commercial vacuum cleaner systems, that is, combination cleaners.
1.2 This test method provides a test for determining operating motor life in hours by an accelerated laboratory procedure. The motors are tested while mounted and operated in the motorized nozzle.
1.3 This test method covers only the motorized nozzle. The system used to provide the airflow source is not under consideration.
1.4 This test method is limited to the determination of motor life for an electrically powered household or commercial motorized nozzle.
1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation:F922–01(Reapproved 2006)
Standard Test Method for
1
Motor Life Evaluation of an Electric Motorized Nozzle
ThisstandardisissuedunderthefixeddesignationF922;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Removal Effectiveness of Household/CommercialVacuum
Cleaners
1.1 This test method covers the motorized nozzle used with
F655 Specification for Test Carpets and Pads for Vacuum
household or commercial vacuum cleaner systems, that is,
Cleaner Testing
combination cleaners.
1.2 This test method provides a test for determining oper-
3. Terminology
ating motor life in hours by an accelerated laboratory proce-
3.1 Description of Term Specific to This Standard:
dure.The motors are tested while mounted and operated in the
3.1.1 motor life—limited by failure of the motor. Failure is
motorized nozzle.
motor stoppage.
1.3 This test method covers only the motorized nozzle. The
3.1.1.1 Discussion—Any failure integral with the motor
system used to provide the airflow source is not under
such as armature assembly, field assembly, housing(s) bear-
consideration.
ings, motor cooling fan, carbon brush assemblies, motor-
1.4 Thistestmethodislimitedtothedeterminationofmotor
mountednonresettablethermalprotectivedevices,oranyother
life for an electrically powered household or commercial
componentjudgedtobeintegralwiththemotorshallbejudged
motorized nozzle.
as motor stoppage.
1.5 The values stated in inch-pound units are to be regarded
as the standard. The values given in parentheses are for
4. Significance and Use
information only.
4.1 Thetestresultsprovideanindicationofthemotorlifeof
1.6 This standard does not purport to address all of the
an electric motorized nozzle. End of motor life will be judged
safety concerns, if any, associated with its use. It is the
in accordance with Section 3.
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
5. Apparatus and Materials
bility of regulatory limitations prior to use.
5.1 Voltage Regulator System,tocontroltheinputvoltageto
the vacuum cleaner. The regulator system shall be capable of
2. Referenced Documents
2 maintainingratedvoltage 61%andratedfrequency 61Hzof
2.1 ASTM Standards:
the motorized nozzle having a wave form that is essentially
D75 Practice for Sampling Aggregates
sinusoidal with 3% maximum harmonic distortion for the
E337 Test Method for Measuring Humidity with a Psy-
duration of the test.
chrometer (the Measurement of Wet- and Dry-Bulb Tem-
5.2 Voltmeter, to provide measurements accurate to within
peratures)
61%.
F431 Specification for Air Performance Measurement Ple-
5.3 Timer and Switch, having the capacity to control the
num Chamber for Vacuum Cleaners
off/on duty cycle of the nozzle and air flow source during the
F608 Test Method for Evaluation of Carpet Embedded Dirt
life test.
5.4 Wattmeter, to provide measurements accurate to within
1
ThistestmethodisunderthejurisdictionofASTMCommitteeF11onVacuum
1%.
Cleaners and is the direct responsibility of Subcommittee F11.30 on Durability- 1
5.5 Sharp-Edge Orifice Plate,a1 ⁄4-in. (32-mm) diameter
Reliability.
shall be in accordance with the orifice plate illustrated in
Current edition approved Jan. 1, 2006. Published January 2006. Originally
Specification F431.
approved in 1988. Last previous edition approved in 2001 as F922–01. DOI:
10.1520/F0922-01R06.
5.6 Plenum Chamber, conforming to the plenum chamber
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
specifications in Specification F431.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.7 Water Manometer, or equivalent instrument measuring
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. in increments of 0.1 in. (2.54 mm).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F922–01 (2006)
5.8 Barometer, with an accuracy of 60.05 in. Hg (1.27 mm cleaner or airflow source shall be stationary and positioned so
Hg), capable of measuring uncorrected barometric pressure that the hose will be submitted to minimum stresses.
with scale divisions of 0.02 in. (0.51 mm) or finer. 5.15 Test Dirt, Wedron sand/talc mixture. See Annex A1.
5.9 Thermometer, having a range of at least 18 to 80°F (−8
6. Sampling
to+27°C) and graduated in 1°F (0.5°C) increments.
5.10 Psychrometer, meeting the requirements of Test 6.1 Testaminimumofthreeunits(oralargersamplesizeif
Method E337 with thermom
...
Questions, Comments and Discussion