ASTM F1373-93(2005)
(Test Method)Standard Test Method for Determination of Cycle Life of Automatic Valves for Gas Distribution System Components
Standard Test Method for Determination of Cycle Life of Automatic Valves for Gas Distribution System Components
SIGNIFICANCE AND USE
The purpose of this test method is to define a procedure for testing components being considered for installation into a high-purity gas distribution system. Application of this test method is expected to yield comparable data among components tested for the purposes of qualification for this installation.
SCOPE
1.1 This test method covers the testing of automatic valves for cycle life utilizing static, no-flow conditions. This no-flow condition is felt to be a realistic test to determine the valve's cycle life.
1.2 This test method applies to automatically operated valves. It is intended to measure the cycle life of the valve itself including the seat and body sealing. It does not include cycle testing of the actuator. Testing must include both pressure testing and helium leak testing and must include vacuum test conditions when appropriate. This test method may be applied to a broad range of valve sizes.
1.3 Limitations:
1.3.1 This test is not designed to evaluate the performance of the actuator. This test method addresses the gas system contamination aspects of the valve performance, that is, seat and body leakage and diaphragm or bellows failure. If the actuator fails during the evaluation, the valve is deemed as a failure.
1.3.2 While the requirements of a valve's performance might include items such as particulate generation levels, this test method only attempts to evaluate cycle life and performance degradation as they relate to the ability of the valve to operate and shut off flow.
1.3.3 This test method is written with the assumption that the operator understands the use of the apparatus at a level equivalent to six months of experience.
1.4 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F1373 − 93(Reapproved 2005)
Standard Test Method for
Determination of Cycle Life of Automatic Valves for Gas
Distribution System Components
This standard is issued under the fixed designation F1373; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
Semiconductor clean rooms are serviced by high-purity gas distribution systems. This test method
presentsaprocedurethatmaybeappliedfortheevaluationofoneormorecomponentsconsideredfor
use in such systems.
1. Scope 1.5 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
1.1 This test method covers the testing of automatic valves
responsibility of the user of this standard to establish appro-
for cycle life utilizing static, no-flow conditions. This no-flow
priate safety and health practices and determine the applica-
condition is felt to be a realistic test to determine the valve’s
bility of regulatory limitations prior to use. Specific hazard
cycle life.
statements are given in Section 7.
1.2 This test method applies to automatically operated
valves.Itisintendedtomeasurethecyclelifeofthevalveitself
2. Referenced Document
including the seat and body sealing. It does not include cycle
2.1 SEMATECH Standard:
testing of the actuator. Testing must include both pressure
2.1.1 Test Method for Determination of Helium Leak Rate
testing and helium leak testing and must include vacuum test
for Gas Distribution Systems Components, Provisional SE-
conditions when appropriate. This test method may be applied
MASPEC #90120391 B-STD. Feb. 22, 1993.
to a broad range of valve sizes.
1.3 Limitations:
3. Terminology
1.3.1 This test is not designed to evaluate the performance
3.1 Definitions of Terms Specific to This Standard:
of the actuator. This test method addresses the gas system
3.1.1 actuation cycle—operationofvalvefromfullyopened
contamination aspects of the valve performance, that is, seat
to fully closed and back to fully opened.
and body leakage and diaphragm or bellows failure. If the
3.1.2 actuator— a gas (compressed air nitrogen)-operated
actuator fails during the evaluation, the valve is deemed as a
deviceconnectedtothevalvestemtoopenandclosethevalve.
failure.
3.1.3 actuator pressure—range of actuator gas line pressure
1.3.2 While the requirements of a valve’s performance
might include items such as particulate generation levels, this required to fully open and close the valve.
test method only attempts to evaluate cycle life and perfor-
3.1.4 automatic valve—avalvewithanactuationdevicethat
mance degradation as they relate to the ability of the valve to
can be operated remotely, such as a pneumatically or electri-
operate and shut off flow.
cally controlled valve.
1.3.3 This test method is written with the assumption that
3.1.5 cycle life—the cycle life of a valve involves two
the operator understands the use of the apparatus at a level
characteristics:catastrophicvalvefailure,thatisasinglevalue;
equivalent to six months of experience.
and a degraded performance, that is, a plot of helium leak rate
1.4 The values stated in SI units are to be regarded as the
versus cycles.
standard. The inch-pound units given in parentheses are for
3.1.6 failure—the termination of the ability of the valve to
information only.
perform its required function.
3.1.7 failure mode—themodebywhichafailureisobserved
This test method is under the jurisdiction of ASTM Committee F01 on
Electronics and is the direct responsibility of Subcommittee F01.10 on Contamina- to occur.
tion Control.
Current edition approved Jan. 1, 2005. Published January 2005. Originally
approved in 1992. Last previous edition approved in 1999 as F1373–93(1999).
DOI: 10.1520/F1373-93R05. Available from SEMATECH, 2706 Montopolis Dr., Austin, TX 78741-6499.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F1373 − 93 (2005)
3.1.7.1 Discussion—Failure mode types include a cata-
strophic failurethatisbothsuddenandcompleteand degraded
failure that is gradual, partial, or both.
3.1.8 standard conditions—101.3 kPa, 0.0°C (14.73 psia,
32.0°F).
3.1.9 valve—any component designed to provide positive
shutoff of fluid media with the capability of being externally
operated.
4. Significance and Use
4.1 The purpose of this test method is to define a procedure
for testing components being considered for installation into a
FIG. 1 Cycle Life Test Schematic
high-purity gas distribution system. Application of this test
method is expected to yield comparable data among compo-
nents tested for the purposes of qualification for this installa-
tion.
8.2 Nitrogen gas supply is filtered by an electronics grade
5. Apparatus
high purity gas filter before it is delivered to the test valve
through the isolation valve. The test valve is isolated between
5.1 Helium Mass Spectrometer Leak Detector.
two isolation valves to allow for pressurization of the test
5.2 Cycle Counter.
componentduringcyclingandleaktesting.Heliumgasneeded
5.3 Upstream and Downstream Pressure Indicators or
forleaktestingisprovidedfromanultrahighpurityheliumgas
Transducers, capable of handling the test pressure ranges; a
cylinder.
vacuum pump for vacuum service valves, an isolation valve
8.3 The test component is installed inside a borosilicate bell
and test valve, some pressure transducers or gages, and a cycle
jar placed above a stainless steel base plate to provide a
controller to provide consistent cycling are required.
leak-tightenclosurerequiredforboththeinboardandoutboard
5.4 Instrument to Detect Failure of the Valve to Hold
helium leak tests. Ports are provided in the base plate for the
Pressure, for example, a data logger tied to the outlet pressure
inlet and outlet lines of the test component, for the actuator
transducer. A data logging instrument is preferred but any
line, and for a port for the actuator exhaust to release the
instrument such as a dual strip chart recorder capable of
exhaust outside the bell jar. The base plate is sealed to the bell
detecting the failure is acceptable.
jar by a rubber gasket during outboard le
...