ASTM D7500-12
(Test Method)Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils—in Boiling Range from 100 to 735°C by Gas Chromatography
Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils—in Boiling Range from 100 to 735°C by Gas Chromatography
SIGNIFICANCE AND USE
5.1 The boiling range distribution of medium and heavy petroleum distillate fractions provides an insight into the composition of feed stocks and products related to petroleum refining processes (for example, hydrocracking, hydrotreating, visbreaking, or deasphalting). The gas chromatographic simulation of this determination can be used to replace conventional distillation methods for control of refining operations. This test method can be used for product specification testing with the mutual agreement of interested parties.
5.2 This test method extends the scope of boiling range determination by gas chromatography to include distillates (IBP > 100°C) and heavy petroleum distillate fractions beyond the scope of Test Method D2887 (538°C).
5.3 Boiling range distributions obtained by this test method have not been analyzed for correlation to those obtained by low efficiency distillation, such as with Test Method D86 or D1160. This test method does not claim agreement between these physical distillations and simulated distillation. Efforts to resolve this question will continue. When successful resolutions of the questions are determined, this test method will be revised accordingly.
SCOPE
1.1 This test method covers the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionization detection. This standard test method has been developed through the harmonization of two test methods, Test Method D6352 and IP 480. As both of these methods cover the same scope and include very similar operating conditions, it was agreed that a single standard method would benefit the global simulated distillation community.
1.2 This test method is not applicable for the analysis of petroleum or petroleum products containing low molecular weight components (for example naphthas, reformates, gasolines, diesel). Components containing hetero atoms (for example alcohols, ethers, acids, or esters) or residue are not to be analyzed by this test method. See Test Methods D7096, D2887, or D7213 for possible applicability to analysis of these types of materials. This method is also not suitable for samples that will not elute completely from the gas chromatographic column, leaving residues. For such samples as crude oils and residues, see Test Methods D5307 and D7169.
1.3 This test method is applicable to distillates with initial boiling points above 100ºC and final boiling points below 735ºC (carbon 110); for example, distillates (IBP > 100°C), base oils and lubricating base stocks.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D7500 − 12
StandardTest Method for
Determination of Boiling Range Distribution of Distillates
and Lubricating Base Oils—in Boiling Range from 100 to
1
735°C by Gas Chromatography
This standard is issued under the fixed designation D7500; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2
1.1 This test method covers the determination of the boiling 2.1 ASTM Standards:
range distribution of petroleum products by capillary gas D86 Test Method for Distillation of Petroleum Products at
chromatography using flame ionization detection. This stan- Atmospheric Pressure
dard test method has been developed through the harmoniza- D1160 Test Method for Distillation of Petroleum Products at
tion of two test methods, Test Method D6352 and IP 480. As Reduced Pressure
both of these methods cover the same scope and include very D2887 Test Method for Boiling Range Distribution of Pe-
similar operating conditions, it was agreed that a single troleum Fractions by Gas Chromatography
standard method would benefit the global simulated distillation D5307 Test Method for Determination of Boiling Range
community. Distribution of Crude Petroleum by Gas Chromatography
3
(Withdrawn 2011)
1.2 This test method is not applicable for the analysis of
D6352 Test Method for Boiling Range Distribution of Pe-
petroleum or petroleum products containing low molecular
troleumDistillatesinBoilingRangefrom174to700°Cby
weight components (for example naphthas, reformates,
Gas Chromatography
gasolines, diesel). Components containing hetero atoms (for
D7096 Test Method for Determination of the Boiling Range
example alcohols, ethers, acids, or esters) or residue are not to
Distribution of Gasoline by Wide-Bore Capillary Gas
be analyzed by this test method. See Test Methods D7096,
Chromatography
D2887,or D7213 for possible applicability to analysis of these
D7169 Test Method for Boiling Point Distribution of
types of materials.This method is also not suitable for samples
Samples with Residues Such as Crude Oils and Atmo-
that will not elute completely from the gas chromatographic
spheric and Vacuum Residues by High Temperature Gas
column, leaving residues. For such samples as crude oils and
Chromatography
residues, see Test Methods D5307 and D7169.
D7213 Test Method for Boiling Range Distribution of Pe-
1.3 This test method is applicable to distillates with initial
troleum Distillates in the Boiling Range from 100 to
boiling points above 100ºC and final boiling points below
615°C by Gas Chromatography
735ºC (carbon 110); for example, distillates (IBP > 100°C),
E355 Practice for Gas ChromatographyTerms and Relation-
base oils and lubricating base stocks.
ships
E594 Practice for Testing Flame Ionization Detectors Used
1.4 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this in Gas or Supercritical Fluid Chromatography
E1510 Practice for Installing Fused Silica Open Tubular
standard.
Capillary Columns in Gas Chromatographs
1.5 This standard does not purport to address all of the
4
safety concerns, if any, associated with its use. It is the 2.2 ISO Standard:
responsibility of the user of this standard to establish appro-
ISO 3170 Petroleum Liquids Manual Sampling
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
This test method is under the jurisdiction of ASTM Committee D02 on Standards volume information, refer to the standard’s Document Summary page on
Petroleum Products and Lubricants and is the direct responsibility of Subcommittee the ASTM website.
3
D02.04.0H on Chromatographic Distribution Methods. The last approved version of this historical standard is referenced on
Current edition approved Nov. 1, 2012. Published April 2013. Originally www.astm.org.
4
approved in 2008. Last previous edition approved in 2010 as D7500-10. DOI: Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
10.1520/D7500-12. 4th Floor, New York, NY 10036, http://www.ansi.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D7500 − 12
3. Terminology Sample vaporization is provided by separate heating of the
point of injection or in conjunction with co
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D7500 − 10 D7500 − 12
Standard Test Method for
Determination of Boiling Range Distribution of Distillates
and Lubricating Base Oils—in Boiling Range from 100 to
1
735°C by Gas Chromatography
This standard is issued under the fixed designation D7500; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This test method covers the determination of the boiling range distribution of petroleum products by capillary gas
chromatography using flame ionization detection. This standard test method has been developed through the harmonization of two
test methods, Test Method D6352 and IP 480. As both of these methods cover the same scope and include very similar operating
conditions, it was agreed that a single standard method would benefit the global simulated distillation community.
1.2 This test method is not applicable for the analysis of petroleum or petroleum products containing low molecular weight
components (for example naphthas, reformates, gasolines, diesel). Components containing hetero atoms (for example alcohols,
ethers, acids, or esters) or residue are not to be analyzed by this test method. See Test Methods D7096, D2887, or D7213 for
possible applicability to analysis of these types of materials. This method is also not suitable for samples that will not elute
completely from the gas chromatographic column, leaving residues. For such samples as crude oils and residues, see Test Methods
D5307 and D7169.
1.3 This test method is applicable to distillates with initial boiling points above 100ºC and final boiling points below 735ºC
(carbon 110); for example, distillates (IBP > 100°C), base oils and lubricating base stocks.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D86 Test Method for Distillation of Petroleum Products at Atmospheric Pressure
D1160 Test Method for Distillation of Petroleum Products at Reduced Pressure
D2887 Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography
D5307 Test Method for Determination of Boiling Range Distribution of Crude Petroleum by Gas Chromatography (Withdrawn
3
2011)
D6352 Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700°C by Gas
Chromatography
D7096 Test Method for Determination of the Boiling Range Distribution of Gasoline by Wide-Bore Capillary Gas
Chromatography
D7169 Test Method for Boiling Point Distribution of Samples with Residues Such as Crude Oils and Atmospheric and Vacuum
Residues by High Temperature Gas Chromatography
D7213 Test Method for Boiling Range Distribution of Petroleum Distillates in the Boiling Range from 100 to 615°C by Gas
Chromatography
1
This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products and Lubricants and is the direct responsibility of Subcommittee D02.04.0H
on Chromatographic Distribution Methods.
Current edition approved May 1, 2010Nov. 1, 2012. Published August 2010April 2013. Originally approved in 2008. Last previous edition approved in 20082010 as
D7500D7500-08.-10. DOI: 10.1520/D7500-10.10.1520/D7500-12.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D7500 − 12
E355 Practice for Gas Chromatography Terms and Relationships
E594 Practice for Testing Flame Ionization Detectors Used in Gas or Supercritical Fluid Chromatography
E1510 Practice for Installing Fused Silica Open Tubular Capillary Colu
...
Questions, Comments and Discussion