Standard Test Method for Compressive Strength of Masonry Prisms

SCOPE
1.1 This test method covers procedures for masonry prism construction and testing, and procedures for determining the compressive strength of masonry, f'mt', used to determine compliance with the specified compressive strength of masonry,  f `m'. When this test method is used for research purposes, the construction and test procedures within serve as a guideline and provide control parameters.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Jan-2002
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C1314-02 - Standard Test Method for Compressive Strength of Masonry Prisms
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

Designation:C1314–02
Standard Test Method for
1
Compressive Strength of Masonry Prisms
This standard is issued under the fixed designation C 1314; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope* 4. Significance and Use
1.1 This test method covers procedures for masonry prism 4.1 This test method provides a means of verifying that
construction and testing, and procedures for determining the masonry materials used in construction result in masonry that
compressive strength of masonry, f , used to determine meets the specified compressive strength.
mt
compliance with the specified compressive strength of ma- 4.2 If this test method is used as a guideline for performing
sonry, f 8 . When this test method is used for research research to determine the effects of various prism construction
m
purposes, the construction and test procedures within serve as or test parameters on the compressive strength of masonry,
a guideline and provide control parameters. deviations from this test method shall be permitted, provided
1.2 The values stated in inch-pound units are to be regarded they are reported. Such research prisms shall not be used to
as the standard. The values given in parentheses are for verify compliance with a specified compressive strength of
information only. masonry.
1.3 This standard does not purport to address all of the
NOTE 1—The testing laboratory performing this test method should be
safety concerns, if any, associated with its use. It is the
evaluated in accordance with Practice C 1093.
responsibility of the user of this standard to establish appro-
5. Masonry Prism Construction
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
5.1 Construct prisms of units representative of those used in
1
the construction. If units have flutes or ribs that project ⁄2 in.
2. Referenced Documents
(12.5 mm) or more from the surface of the unit, remove those
2.1 ASTM Standards:
flutes or ribs by saw cutting flush with the surface of the unit
C 67 Test Methods for Sampling and Testing Brick and
at the base of the flute or rib.
2
Structural Clay Tile
5.2 Construct a set of prisms for each combination of
C 140 Test Methods for Sampling and Testing Concrete
materials and each test age at which the compressive strength
2
Masonry Units and Related Units
of masonry is to be determined.
C 1093 Practice for Accreditation of Testing Agencies for
5.3 Build each prism in an opened, moisture-tight bag large
2
Unit Masonry
enough to enclose and seal the completed prism. Construct
prisms on a flat, level base. Construct prisms in a location
3. Terminology
where they will remain undisturbed until transported for
3.1 Definitions:
testing.
3.1.1 set—a set consists of at least three prisms constructed
5.4 Construct prisms as shown in Fig. 1 with units laid in
of the same material and tested at the same age.
stack bond in stretcher position. Orient units in the prism as in
3.2 Notations:
the corresponding construction.At the time of prism construc-
3.2.1 f 8 —specified compressive strength of masonry.
m
tion, the surfaces of the units shall be free of moisture. Where
3.2.2 f —compressive strength of masonry.
mt
the corresponding construction is of multi-wythe masonry
3.2.3 h —prism height.
p
having wythes composed of different units or mortar, build
3.2.4 t —least actual lateral dimension of prism.
p
prisms representative of each different wythe and test sepa-
rately.
5.5 The length of masonry prisms may be reduced from that
1
This test method is under the jurisdiction of ASTM Committee C15 on
of an individual unit by saw cutting units prior to prism
Manufactured Masonry Units and is the direct responsibility of Subcommittee
C15.04 on Research.
construction. Prisms composed of units that contain closed
Current edition approved Jan. 10, 2002. Published March 2002. Originally
cells shall have at least one complete cell with one full-width
published as C 1314–95. Last previous edition C 1314–01.
cross web on either end (see Fig. 2). Prisms composed of units
2
Annual Book of ASTM Standards, Vol 04.05.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1314–02
FIG. 1 Masonry Prism Construction
than 48 h following the construction of the prisms. Use grout
representative of that used in the corresponding construction.
Before placing grout, remove mortar droppings from the grout
space. Use grout consolidation and reconsolidation procedures
representative of those used in the construction. Place addi-
tional grout into the prisms as necessary after
...