ASTM E1976-01
(Specification)Standard Specification for Shelter, Tactical, Nonexpandable
Standard Specification for Shelter, Tactical, Nonexpandable
SCOPE
1.1 This specification covers a rigid wall, nonexpandable shelter constructed of aluminum-faced, nonmetallic honeycomb sandwich panels, and meeting the International Organization for Standardization (ISO) Cargo Container specification. Nominal dimensions are: height 8ft, width 8 ft and length 20 ft (2.4 by 2.4 by 6.1m).
1.2 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are for information only.
1.3 The following precautionary statement pertains to the test method portion only, Section 7, of this specification: This statement does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: E 1976 – 01
Standard Specification for
1
Shelter, Tactical, Nonexpandable
This standard is issued under the fixed designation E 1976; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
2
1. Scope loys to Be Adhesively Bonded
E 1925 Specification for Engineering and Design Criteria
1.1 This specification covers a rigid wall, nonexpandable
2
for Rigid Wall Relocatable Structures
shelter constructed of aluminum-faced, nonmetallic honey-
2.2 ISO Standards:
comb sandwich panels, and meeting the International Organi-
ISO 1161-1980 Series 1-Freight Containers-Corner Fittings,
zation for Standardization (ISO) Cargo Container specification.
3
Specification
Nominal dimensions are: height 8 ft, width 8 ft and length 20
ISO 1496/I Series 1-Freight Containers-Specification and
ft (2.4 by 2.4 by 6.1 m).
3
Testing Part I-General Cargo Containers
1.2 The values stated in inch-pound units are to be regarded
2.3 Military Standards:
as the standard. The SI units given in parentheses are for
4
MIL-Q-9858 Quality Program Requirements
information only.
4
MIL-STD-129 Marking for Shipping and Storage
1.3 The following precautionary statement pertains to the
MIL-STD-810 Environmental Engineering Considerations
test method portion only, Section 7, of this specification: This
4
and Laboratory Tests
statement does not purport to address all of the safety
MIL-STD-1595 Qualification of Aircraft, Missile and Aero-
concerns, if any, associated with its use. It is the responsibility
4
space Fusion Welders
of the user of this standard to establish appropriate safety and
4
MIL-STD-2219 Fusion Welding for Aerospace Appliances
health practices and determine the applicability of regulatory
2.4 ANSI/ASQC Standard:
limitations prior to use.
ANSI/ASQC Z1.4-1993 Sampling Procedures and Tables
5
2. Referenced Documents for Inspection by Attributes
2.5 Drawings:
2.1 ASTM Standards:
6
5-4-3141 Shelter, Assembly, Non-Expandable-60 amp
E 864 Practice for Surface Preparation of Aluminum Alloys
6
2
5-4-6865 Shelter, Assembly, Non-Expandable-100 amp
to Be Adhesively Bonded in Honeycomb Shelter Panels
E 865 Specification for Structural Film Adhesives for Hon-
3. General Requirements
2
eycomb Sandwich Panels
3.1 Alternate Components—When this specification or the
E 866 Specification for Corrosion-Inhibiting Adhesive
referenced drawings specify use of a specific component “or
Primer for Aluminum Alloys to Be Adhesively Bonded in
2
equal”, the contractor may substitute a component equal to the
Honeycomb Shelter Panels
specified component provided that the contractor complies
E 874 Practice for Adhesive Bonding of Aluminum Facings
2
with the following requirements. Prior to manufacture of the
to Nonmetallic Honeycomb Core for Shelter Panels
first article, or if none is required, prior to commencing
E 990 Specification for Core-Splice Adhesive for Honey-
2 production, the contractor shall submit for the purchaser’s
comb Sandwich Shelter Panels
approval, a list identifying each proposed “or equal” compo-
E 1091 Specification for Nonmetallic Honeycomb Core for
2 nent together with proof that each listed component is func-
Use in Shelter Panels
tionally equal to the specified component and is compatible
E 1749 Terminology Relating to Rigid Wall Relocatable
2 with the end item covered by this specification. The purchaser,
Shelters
at his option, may require a physical sample of any “or equal”
E 1773 Practice for Sealing Rigid Wall Tactical Shelters
2 component. Approval of the submitted listing and supporting
with Polysulfide Based Sealants
E 1826 Specification for Low Volatile Organic (VOC)
Corrosion-Inhibiting Adhesive Primer for Aluminum Al-
3
Available from American National Standards Institute, 11 W. 42nd St., 13th
Floor, New York, NY 10036.
4
Available from Standardization Documents Order Desk, Bldg. 4, Section D,
1
This specification is under the jurisdiction of ASTM Committee E06 on 700 Robbins Ave., Philadelphia, PA 19111–5094, Attn: NPODS.
5
Performance of Buildings and is the direct responsibility of Subcommittee E06.53 Available from American Society for Quality Control, 611 East Wisconsin
on Materials and Processes for Durable Rigidwall Relocatable Structures. Avenue, Milwaukee, WI 53201.
6
Current edition approved April 10, 2001. Published May 2001. Originally Copies of drawings are available from the U.S. Army Natick Research,
approved as E 1976–98. Last previous edition E 1976–98. Development, and Engineering Center, Attn: SSCNC-WST, Natick, MA
2
Annual Book of ASTM Standards, Vol 04.11. 07160–5018.
Copyright © ASTM, 100 Barr Harbor Drive, West Con
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.