Standard Specification for Expanded Polystyrene (“EPS”) Thermal Insulation Boards for Use in Exterior Insulation and Finish Systems (“EIFS”)

ABSTRACT
This specification is for flat, uncoated expanded polystyrene thermal insulation boards for use in exterior insulation and finish systems (EIFS). The thermal insulation boards shall be made of a particular percentage of virgin EPS . Properties of thermal insulation boards such as length, width, thickness, edge trueness, face flatness, and squareness shall be observed.
SCOPE
1.1 This specification is for flat, uncoated expanded polystyrene thermal insulation boards for use in exterior insulation and finish systems (EIFS).  
1.2 EIFS producers may have requirements in addition to, or different than, those in this specification.  
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Mar-2019
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E2430/E2430M-19 - Standard Specification for Expanded Polystyrene (“EPS”) Thermal Insulation Boards for Use in Exterior Insulation and Finish Systems (“EIFS”)
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM E2430/E2430M-19 - Standard Specification for Expanded Polystyrene (“EPS”) Thermal Insulation Boards for Use in Exterior Insulation and Finish Systems (“EIFS”)
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E2430/E2430M − 19
Standard Specification for
Expanded Polystyrene (“EPS”) Thermal Insulation Boards
1
for Use in Exterior Insulation and Finish Systems (“EIFS”)
This standard is issued under the fixed designation E2430/E2430M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3. Terminology
1.1 This specification is for flat, uncoated expanded poly- 3.1 For general terminology regarding EIFS and building in
styrene thermal insulation boards for use in exterior insulation general, see Terminology E2110 (for EIFS terms) and Termi-
and finish systems (EIFS). nology E631 (for buildings in general).
1.2 EIFS producers may have requirements in addition to,
4. Ordering Information
or different than, those in this specification.
4.1 The following information shall be provided when
1.3 The values stated in either SI units or inch-pound units
shipping materials under this specification:
are to be regarded separately as standard. The values stated in
4.1.1 Thickness, width and length;
each system are not necessarily exact equivalents; therefore, to
4.1.2 Number of pieces;
ensure conformance with the standard, each system shall be
4.1.3 Shipping address;
used independently of the other, and values from the two
4.1.4 Required delivery date;
systems shall not be combined.
4.1.5 Billing information;
1.4 This standard does not purport to address all of the
4.1.6 Certificate of compliance with this specification; and
safety concerns, if any, associated with its use. It is the
4.1.7 EIFS producer name and product name for which
responsibility of the user of this standard to establish appro-
insulation is to be used.
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
5. Requirements
1.5 This international standard was developed in accor-
5.1 The thermal insulation boards shall meet the following
dance with internationally recognized principles on standard-
requirements:
ization established in the Decision on Principles for the
5.1.1 Insulation boards shall meet the properties listed in
Development of International Standards, Guides and Recom-
Table 1 of Specification C578 for Type I.
mendations issued by the World Trade Organization Technical
5.1.2 Insulation boards shall be made of 100 % virgin EPS.
Barriers to Trade (TBT) Committee.
1
5.1.3 Length—1219 mm [48 in.] 6 1.6 mm [6 ⁄16 in.].
1
5.1.4 Width—610 mm [24 in.] 6 1.6 mm [6 ⁄16 in.].
2. Referenced Documents
5.1.5 Thickness:
2
2.1 ASTM Standards: 3 1
5.1.5.1 Minimum: 20 mm [ ⁄4 in.] + 1.6 mm [ ⁄16 in.].
C578 Specification for Rigid, Cellular Polystyrene Thermal
1
5.1.5.2 Maximum: as specified + 1.6 mm [ ⁄16 in.].
Insulation
5.1.6 Edge Trueness—When measured with a straight edge,
E631 Terminology of Building Constructions
1
edges shall not deviate more that 0.8 mm [ ⁄32 in.] in 305 mm
E2110 Terminology for Exterior Insulation and Finish Sys-
[12 in.].
tems (EIFS)
5.1.7 Face Flatness—When measured across the face with a
straight edge, the maximum deviation for the straight edge
1
shall not exceed more than 0.8 mm [ ⁄32 in.].
1
This specification is under the jurisdiction of ASTM Committee E06 on
5.1.8 Squareness—When measured on the large flat face
Performance of Buildings and is the direct responsibility of Subcommittee E06.58
from one corner to the opposing corner, the dimensional
on Exterior Insulation and Finish Systems (EIFS).
1
variations shall not exceed more than 0.8 mm [ ⁄32 in.] in
Current edition approved April 1, 2019. Published May 2019. Originally
305 mm [12 in.].
approved in 2005. Last previous edition approved in 2018 as E2430/E2430M–13
(2018). DOI: 10.1520/E2430_E2430M–19.
5.1.9 Aging—Prior to cutting into individual boards, the
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
insulation billet shall remain in one of the following states:
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.1.9.1 For a minimum of six weeks at ambient tempera-
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. tures and humidity conditions of the storage locations.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2430/E2430M − 19
5.1.9.2 For a minimum of five days at a constant tempera- 6.2 Voids—Insulation board s
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E2430/E2430M − 13 (Reapproved 2018) E2430/E2430M − 19
Standard Specification for
Expanded Polystyrene (“EPS”) Thermal Insulation Boards
1
for Use in Exterior Insulation and Finish Systems (“EIFS”)
This standard is issued under the fixed designation E2430/E2430M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification is for flat, uncoated expanded polystyrene thermal insulation boards for use in exterior insulation and
finish systems (EIFS).
1.2 EIFS producers may have requirements in addition to, or different than, those in this specification.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system mayare not benecessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used
independently of the other. Combiningother, and values from the two systems may result in non-conformance with the
standard.shall not be combined.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C578 Specification for Rigid, Cellular Polystyrene Thermal Insulation
E631 Terminology of Building Constructions
E2110 Terminology for Exterior Insulation and Finish Systems (EIFS)
3. Terminology
3.1 For general terminology regarding EIFS and building in general, see Terminology E2110 (for EIFS terms) and Terminology
E631 (for buildings in general).
4. Ordering Information
4.1 The following information shall be provided when shipping materials under this specification.specification:
4.1.1 Thickness, width and length,length;
4.1.2 Number of pieces,pieces;
4.1.3 Shipping address,address;
4.1.4 Required delivery date,date;
4.1.5 Billing information,information;
4.1.6 Certificate of compliance with this specification,specification; and
4.1.7 EIFS producer name and product name for which insulation is to be used.
1
This specification is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.58 on Exterior
Insulation and Finish Systems (EIFS).
Current edition approved Sept. 1, 2018April 1, 2019. Published September 2018May 2019. Originally approved in 2005. Last previous edition approved in 20132018 as
E2430/E2430M–13. –13 (2018). DOI: 10.1520/E2430_E2430M-13R18.10.1520/E2430_E2430M–19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2430/E2430M − 19
5. Requirements
5.1 The thermal insulation boards shall meet the following requirements.requirements:
5.1.1 Insulation boards shall meet the properties listed in Table 1 of Specification C578 for Type I.
5.1.2 Insulation boards shall be made of 100 % virgin EPS.
1
5.1.3 Length—1219 mm [48 in.] 6 1.6 mm [6 ⁄16 in.].
1
5.1.4 Width—610 mm [24 in.] 6 1.6 mm [6 ⁄16 in.].
5.1.5 Thickness:
3 1
5.1.5.1 Minimum: 20 mm [ ⁄4 in.] + 1.6 mm [ ⁄16 in.].
1
5.1.5.2 Maximum: as specified.specified + 1.6 mm [ ⁄16 in.].
1
5.1.6 Edge Trueness—When measured with a straight edge, edges shall not deviate more that 0.8 mm [ ⁄32 in.] in 305 mm [12
in.].
5.1.7 Face Flatness—When measured across the face with a straight edge, the maximum deviation for the straight edge shall
1
not exceed more than 0.8 mm [ ⁄32 in.].
5.1.8 Squareness—When measured on the large flat face from one corner to the opposing corner, the dimensional variations
1
shall not exceed mor
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.