Standard Test Method for Compressive Strength of Masonry Prisms

SIGNIFICANCE AND USE
This test method provides a means of verifying that masonry materials used in construction result in masonry that meets the specified compressive strength.
This test method provides a means of evaluating compressive strength characteristics of in-place masonry construction through testing of prisms obtained from that construction when sampled in accordance with Practice C 1532. Decisions made in preparing such field-removed prisms for testing, determining the net area, and interpreting the results of compression tests require professional judgment.  
If this test method is used as a guideline for performing research to determine the effects of various prism construction or test parameters on the compressive strength of masonry, deviations from this test method shall be reported. Such research prisms shall not be used to verify compliance with a specified compressive strength of masonry.
Note 1—The testing laboratory performing this test method should be evaluated in accordance with Practice C 1093.
4.3.1 Appendix X2 includes guidance information for the researcher on aspects of materials, construction, and analysis.
SCOPE
1.1 This test method covers procedures for masonry prism construction and testing, and procedures for determining the compressive strength of masonry, fmt, used to determine compliance with the specified compressive strength of masonry,  f `m. When this test method is used for research purposes, the construction and test procedures within serve as a guideline and provide control parameters.
1.2 This test method also covers procedures for determining the compressive strength of prisms obtained from field-removed masonry specimens.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-May-2007
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C1314-07 - Standard Test Method for Compressive Strength of Masonry Prisms
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C1314-07 - Standard Test Method for Compressive Strength of Masonry Prisms
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information.
Designation:C1314–07
Standard Test Method for
1
Compressive Strength of Masonry Prisms
This standard is issued under the fixed designation C1314; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* C780 Test Method for Preconstruction and Construction
Evaluation of Mortars for Plain and Reinforced Unit
1.1 This test method covers procedures for masonry prism
Masonry
construction and testing, and procedures for determining the
C1019 Test Method for Sampling and Testing Grout
compressive strength of masonry, f , used to determine
mt
C1093 Practice for Accreditation of Testing Agencies for
compliance with the specified compressive strength of ma-
Masonry
sonry, f 8 . When this test method is used for research
m
C1532 Practice for Selection, Removal, and Shipment of
purposes, the construction and test procedures within serve as
Manufactured Masonry Units and Masonry Specimens
a guideline and provide control parameters.
from Existing Construction
1.2 This test method also covers procedures for determining
C1552 Practice for Capping Concrete Masonry Units, Re-
the compressive strength of prisms obtained from field-
lated Units and Masonry Prisms for Compression Testing
removed masonry specimens.
C1587 PracticeforPreparationofFieldRemovedManufac-
1.3 The values stated in inch-pound units are to be regarded
tured Masonry Units and Masonry Specimens for Testing
as the standard. The values given in parentheses are for
E105 Practice for Probability Sampling Of Materials
information only.
E111 Test Method forYoung’s Modulus, Tangent Modulus,
1.4 This standard does not purport to address all of the
and Chord Modulus
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
3. Terminology
priate safety and health practices and determine the applica-
3.1 Definitions:
bility of regulatory limitations prior to use.
3.1.1 set—a set consists of at least three prisms constructed
2. Referenced Documents of the same material and tested at the same age.
2 3.2 Notations:
2.1 ASTM Standards:
3.2.1 f 8 —specified compressive strength of masonry.
m
C67 Test Methods for Sampling and Testing Brick and
3.2.2 f —compressive strength of masonry.
Structural Clay Tile mt
3.2.3 h —prism height.
p
C136 Test Method for Sieve Analysis of Fine and Coarse
3.2.4 t —least actual lateral dimension of prism.
Aggregates p
C140 Test Methods for Sampling and Testing Concrete
4. Significance and Use
Masonry Units and Related Units
4.1 This test method provides a means of verifying that
C143/C143M Test Method for Slump of Hydraulic-Cement
masonry materials used in construction result in masonry that
Concrete
meets the specified compressive strength.
C144 Specification for Aggregate for Masonry Mortar
4.2 This test method provides a means of evaluating com-
C270 Specification for Mortar for Unit Masonry
pressive strength characteristics of in-place masonry construc-
C476 Specification for Grout for Masonry
tion through testing of prisms obtained from that construction
when sampled in accordance with Practice C1532. Decisions
1
This test method is under the jurisdiction of ASTM Committee C15 on
made in preparing such field-removed prisms for testing,
Manufactured Masonry Units and is the direct responsibility of Subcommittee
determining the net area, and interpreting the results of
C15.04 on Research.
compression tests require professional judgment.
Current edition approved June 1, 2007. Published August 2007. Originally
approved in 1995. Last previous edition approved in 2003 as C1314 – 03b. DOI: 4.3 If this test method is used as a guideline for performing
10.1520/C1314-07.
research to determine the effects of various prism construction
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
or test parameters on the compressive strength of masonry,
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
deviations from this test method shall be reported. Such
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1314–07
research prisms shall not be used to verify compliance with a
specified compressive strength of masonry.
NOTE 1—The testing laboratory performing this test method should be
evaluated in accordance with Practice C1093.
4.3.1 Appendix X2 includes guida
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C1314–03b Designation:C1314–07
Standard Test Method for
1
Compressive Strength of Masonry Prisms
This standard is issued under the fixed designation C 1314; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This test method covers procedures for masonry prism construction and testing, and procedures for determining the
compressivestrengthofmasonry,f ,usedtodeterminecompliancewiththespecifiedcompressivestrengthofmasonry,f 8 .When
mt m
this test method is used for research purposes, the construction and test procedures within serve as a guideline and provide control
parameters.
1.2The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information
only.
1.3
1.2 This test method also covers procedures for determining the compressive strength of prisms obtained from field-removed
masonry specimens.
1.3 Thevaluesstatedininch-poundunitsaretoberegardedasthestandard.Thevaluesgiveninparenthesesareforinformation
only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C67 Test Methods for Sampling and Testing Brick and Structural Clay Tile
C136
C 136 Test Method for Sieve Analysis of Fine and Coarse Aggregates
C 140 Test Methods for Sampling and Testing Concrete Masonry Units and Related Units
C143Test Method for Slump of Hydraulic Cement Concrete
C144
C 143/C 143M Test Method for Slump of Hydraulic-Cement Concrete
C 144 Specification for Aggregate for Masonry Mortar
C270
C 270 Specification for Mortar for Unit Masonry
C476
C 476 Specification for Grout for Masonry
C780
C 780 Test Method for Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry
C1019
C 1019 Test Method for Sampling and Testing Grout
C 1093 Practice for Accreditation of Testing Agencies for Unit Masonry
C 1532 Practice for Selection, Removal, and Shipment of Manufactured Masonry Units and Masonry Specimens from Existing
Construction
C 1552 Practice for Capping Concrete Masonry Units, Related Units, and Masonry Prisms for Compression Testing
E105Practice for Probability Sampling of Materials
E111Practice for Capping Concrete Masonry Units, Related Units and Masonry Prisms for Compression Testing
1
ThistestmethodisunderthejurisdictionofASTMCommitteeC15onManufacturedMasonryUnitsandisthedirectresponsibilityofSubcommitteeC15.04onResearch.
Current edition approved DecemberJune 1, 2003.2007. Published January 2004.August 2007. Originally approved in 1995. Last previous edition approved in 2003 as
C 1314 – 03ab.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1314–07
C 1587 Practice for Preparation of Field Removed Manufactured Masonry Units and Masonry Specimens for Compressive
Strength Testing
E 105 Practice for Probability Sampling Of Materials
E 111 Test Method for Young’s Modulus, Tangent Modulus, and Chord Modulus
3. Terminology
3.1 Definitions:
3.1.1 set—a set consists of at least three prisms constructed of the same material and tested at the same age.
3.2 Notations:
3.2.1 f 8 —specified compressive strength of masonry.
m
3.2.2 f —compressive strength of masonry.
mt
3.2.3 h —prism height.
p
3.2.4 t —least actual lateral dimension of prism.
p
4. Significance and Use
4.1 This test method provides a means of verifying that masonry materials used in construction result in masonry that meets
the specified compressive strength.
4.2If this test method is used as a guideline for performing research to determine the effects of various prism construction or
test parameters on the compressive strength of masonry, deviations from this test method shall be reported.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.