ASTM F1698-21
(Practice)Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of Existing Man-Entry Sewers and Conduits
Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of Existing Man-Entry Sewers and Conduits
SIGNIFICANCE AND USE
4.1 This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations involved in the rehabilitation of non-pressure sewers and conduits. As for any practice, modifications may be required for specific job conditions.
SCOPE
1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits by the installation of a field-fabricated PVC liner. After installation of the liner, cementitious grout is injected into the annular space between the liner and the existing sewer or conduit. The rehabilitation of the host structure by this installation practice results in a rigid composite structure (PVC/grout/existing pipe). This rehabilitation process may be used in a variety of gravity applications, such as sanitary sewers, storm sewers and process piping of man-entry sizes (36 to 144 in. in vertical dimension). The profile strips used for field fabrication of PVC liners are supplied in coils for spiral winding of the liner or in custom-cut flat panels for circumferential lining of all or any portion of the circumference of the host conduit (see Figs. 1 and 2).
FIG. 1 Example of Profile PVC Strip
FIG. 2 Typical Installations with Panels
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F1698 −21
Standard Practice for
Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner
and Cementitious Grout for Rehabilitation of Existing Man-
1
Entry Sewers and Conduits
This standard is issued under the fixed designation F1698; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This practice describes the procedures for the rehabili-
C942Test Method for Compressive Strength of Grouts for
tation of sewer lines and conduits by the installation of a
Preplaced-Aggregate Concrete in the Laboratory
field-fabricated PVC liner. After installation of the liner,
D790Test Methods for Flexural Properties of Unreinforced
cementitious grout is injected into the annular space between
and Reinforced Plastics and Electrical Insulating Materi-
thelinerandtheexistingsewerorconduit.Therehabilitationof
als
the host structure by this installation practice results in a rigid
D883Terminology Relating to Plastics
composite structure (PVC/grout/existing pipe).This rehabilita-
D1600TerminologyforAbbreviatedTermsRelatingtoPlas-
tion process may be used in a variety of gravity applications,
tics
such as sanitary sewers, storm sewers and process piping of
F412Terminology Relating to Plastic Piping Systems
man-entry sizes (36 to 144 in. in vertical dimension). The
F1735Specification for Poly (Vinyl Chloride) (PVC) Profile
profile strips used for field fabrication of PVC liners are
suppliedincoilsforspiralwindingofthelinerorincustom-cut Strip for PVC Liners for Rehabilitation of Existing Man-
Entry Sewers and Conduits
flatpanelsforcircumferentialliningofalloranyportionofthe
circumference of the host conduit (see Figs. 1 and 2).
2.2 NASSCO Standard:
SpecificationGuidelinesforSewerCollectionSystemMain-
1.2 Thevaluesstatedininch-poundunitsaretoberegarded
3
tenance and Rehabilitation
as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only
3. Terminology
and are not considered standard.
3.1 General—Definitions are in accordance with Termi-
1.3 This standard does not purport to address all of the
nologiesD883andF412.Abbreviationsareinaccordancewith
safety concerns, if any, associated with its use. It is the
Terminology D1600, unless otherwise indicated.
responsibility of the user of this standard to establish appro-
3.2 Definitions of Terms Specific to This Standard:
priate safety, health, and environmental practices and deter-
3.2.1 extruded PVC joiner strip—a companion product to
mine the applicability of regulatory limitations prior to use.
the profile former strip of such configuration as to provide the
Particular attention is drawn to those safety regulations and
locking mechanism at the edges of the former strips; the joiner
requirements involving entering into and working in confined
strip contains within it a coextruded flexible PVC seal which
spaces.
forms a compression seal when mated with the edges of the
1.4 This international standard was developed in accor-
former strips.
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the
3.2.2 extruded PVC profile former strip—a product, avail-
Development of International Standards, Guides and Recom-
able in various sizes, consisting of a smooth inner surface and
mendations issued by the World Trade Organization Technical
a ribbed outer surface (profile) with edge configurations to
Barriers to Trade (TBT) Committee.
allow mechanical locking of adjacent strips.
1 2
This practice is under the jurisdiction of ASTM Committee F17 on Plastic For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Piping Systems and is the direct responsibility of Subcommittee F17.67 on contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Trenchless Plastic Pipeline Technology. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved July 1, 2021. Published August 2021. Originally the ASTM website.
ɛ1 3
approved in 2002. Last previous edition approved in 2015 as F1698–02 (2015) . Available from, NASSCO, Inc., 2470 Longstone Lane, Suite M, Marriottsville,
DOI: 10.1520/F1698-21. MD 21104, http://www.nassco.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 --------------------
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: F1698 − 02 (Reapproved 2015) F1698 − 21
Standard Practice for
Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner
and Cementitious Grout for Rehabilitation of Existing Man-
1
Entry Sewers and Conduits
This standard is issued under the fixed designation F1698; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Sections 2.1 and 5.1 were editorially corrected in May 2017.
1. Scope
1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits by the installation of a field-fabricated
PVC liner. After installation of the liner, cementitious grout is injected into the annular space between the liner and the existing
sewer or conduit. The rehabilitation of the host structure by this installation practice results in a rigid composite structure
(PVC/grout/existing pipe). This rehabilitation process may be used in a variety of gravity applications, such as sanitary sewers,
storm sewers and process piping of man-entry sizes (36 to 144 in. in vertical dimension). The profile strips used for field fabrication
of PVC liners are supplied in coils for spiral winding of the liner or in custom-cut flat panels for circumferential lining of all or
any portion of the circumference of the host conduit (see Figs. 1 and 2).
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements
involving entering into and working in confined spaces.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C942 Test Method for Compressive Strength of Grouts for Preplaced-Aggregate Concrete in the Laboratory
C969D790 Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer LinesTest
Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D883 Terminology Relating to Plastics
D1600 Terminology for Abbreviated Terms Relating to Plastics
F412 Terminology Relating to Plastic Piping Systems
1
This practice is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless Plastic
Pipeline Technology.
Current edition approved March 1, 2015July 1, 2021. Published April 2015August 2021. Originally approved in 2002. Last previous edition approved in 20082015 as
ɛ1
F1698–02 (2008).(2015) . DOI: 10.1520/F1698-02R15E01.10.1520/F1698-21.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F1698 − 21
FIG. 1 Example of Profile PVC Strip
F1735 Specification for Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry
Sewers and Conduits
2.2 NASSCO Standard:
3
Specification Guidelines for Sewer Collection System Maintenance and Rehabilitation
3. Terminology
3.1 General—Definitions are in accordance with Terminologies D883 and F412. Abbreviations are in accordance with
Terminology D1600, unless otherwise indicated.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 extruded PVC joiner strip—a companion product to the profile former strip of such configuration as to provide the locking
mechanism at the edges
...