ASTM C1227-02b
(Specification)Standard Specification for Precast Concrete Septic Tanks
Standard Specification for Precast Concrete Septic Tanks
SCOPE
1.1 This specification covers design requirements manufacturing practices, and performance requirements for monolithic or sectional precast concrete septic tanks.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 1227 – 02b
Standard Specification for
1
Precast Concrete Septic Tanks
This standard is issued under the fixed designation C 1227; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
4
1. Scope C 150 Specification for Portland Cement
C 231 Test Method for Air Content of Freshly Mixed
1.1 This specification covers design requirements, manufac-
3
Concrete by the Pressure Method
turing practices, and performance requirements for monolithic
C 260 Specification for Air-Entraining Admixtures for Con-
or sectional precast concrete septic tanks.
3
crete
1.2 The values stated in SI units are to be regarded as the
C 330 Specification for Lightweight Aggregates for Struc-
standard. The values given in parentheses are for information
3
tural Concrete
only.
3
C 494 Specification for Chemical Admixtures for Concrete
1.3 This standard does not purport to address all of the
4
C 595 Specification for Blended Hydraulic Cements
safety concerns, if any, associated with its use. It is the
C 618 Specification for Coal Fly Ash and Raw or Calcined
responsibility of the user of this standard to establish appro-
Natural Pozzolan for Use as a Mineral Admixture in
priate safety and health practices and determine the applica-
3
Concrete
bility of regulatory limitations prior to use.
C 685 Specification for Concrete Made by Volumetric
3
2. Referenced Documents
Batching and Continuous Mixing
C 890 Practice for Minimum Structural Design Loading for
2.1 ASTM Standards:
Monolithic or Sectional Precast Concrete Water and
A 82 Specification for Steel Wire, Plain, for Concrete Re-
5
2
Wastewater Structures
inforcement
C 1116 Specification for Fiber Reinforced Concrete and
A 184/A 184M Specification for Welded Deformed Steel
3
2
Shotcrete
Bar Mats for Concrete Reinforcement
6
2.2 ACI Standard:
A 185 Specification for Steel Welded Wire Reinforcement,
2
ACI 318-89 Building Code Requirements for Reinforced
Plain, for Concrete
Concrete
A 496 Specification for Steel Wire, Deformed, for Concrete
2
Reinforcement
3. Terminology
A 497 Specification for Steel Welded Wire Reinforcement,
2
3.1 For definitions of terms relating to concrete, see Termi-
Deformed, for Concrete
nology C 125.
A 615/A 615M Specification for Deformed and Plain
2
3.2 Definitions of Terms Specific to This Standard:
Billet-Steel Bars for Concrete Reinforcement
3.2.1 access opening, n—a hole in the top slab used to gain
A 616/A 616M Specification for Rail-Steel Deformed and
2 access to the inside of the tank for the purpose of cleaning and
Plain Bars for Concrete Reinforcement
removing sludge without a person actually having to enter the
A 617/A 617M Specification for Axle-Steel Deformed and
2 tank.
Plain Bars for Concrete Reinforcement
3
3.2.2 air scum volume, n—the number of cubic inches
C 33 Specification for Concrete Aggregates
(centimetres) in the space between the liquid surface and the
C 39 Test Method for Compressive Strength of Cylindrical
3
underside of the top slab.
Concrete Specimens
3 3.2.3 inspection opening, n—a hole in the top slab used for
C 94 Specification for Ready-Mixed Concrete
the purpose of observing conditions inside the tank.
C 125 Terminology Relating to Concrete and Concrete
3 3.2.4 joint, n—a physical separation where two pieces of
Aggregates
precast concrete are in contact.
3.2.5 non-sealed joint, n—a joint where sealant is not used
1 but where a machined fit will minimize the movement of liquid
This specification is under the jurisdiction of ASTM Committee C27 on Precast
from one side of a precast concrete wall to the opposite side.
Concrete Products and is the direct responsibility of Subcommittee C27.30 on Water
and Wastewater Containers.
Current edition approved Aug. 10, 2002. Published September 2002. Originally
4
published as C 1227–93. Last previous edition C 1227–02a. Annual Book of ASTM Standards, Vol 04.01.
2 5
Annual Book of ASTM Standards, Vol 01.04. Annual Book of ASTM Standards, Vol 04.05.
3 6
Annual Book of ASTM Standards, Vol 04.02. American Concrete Institute (ACI), Box 9094, Farmington Hills, MI 48333.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C 1227 – 02b
3.2.6 owner, n—is by definition end user, customer, or 5.5.2 Holding Reinforcement in Position During Pouring
purchaser. Placement—Reinforcement must be securely tied in place to
3.2.7 sea
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.