ASTM C1190-95(2010)
(Practice)Standard Practice for Location of Test Specimens from Magnesia-Carbon and Impregnated Burned Basic Brick
Standard Practice for Location of Test Specimens from Magnesia-Carbon and Impregnated Burned Basic Brick
SIGNIFICANCE AND USE
This practice defines a procedure that ensures reasonably consistent preparation of specimens for product testing and evaluation.
This practice can be used in the laboratories of producers, users, and general interest parties for research and development or quality control work. It is particularly useful for interlaboratory comparisons on products, for repetitive evaluations or comparisons of products or product quality, and in specifying a uniform preparation practice for specimens for acceptance testing.
If pitch impregnated samples are prepared by wet cutting or drilling, care should be taken in drying them. If the samples are heated to facilitate drying, the temperature to which they are heated should not be so high that it causes drainage of pitch from the samples.
Porosities of metal-containing brick must be measured using kerosene or mineral spirits because using water will result in an artificially low result.
SCOPE
1.1 This practice covers a procedure for preparing test specimens from magnesia-carbon and impregnated burned basic brick. This practice generally concerns preparation of test specimens from brick greater than 13 in. (33 cm) in length. These brick are mainly manufactured for use in electric arc furnaces and basic oxygen furnaces.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1190 − 95 (Reapproved 2010)
Standard Practice for
Location of Test Specimens from Magnesia-Carbon and
Impregnated Burned Basic Brick
This standard is issued under the fixed designation C1190; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope to characterize the product for the following physical proper-
ties: hot modulus of rupture (MOR), as-received porosity,
1.1 This practice covers a procedure for preparing test
coked porosity, ignited porosity, carbon properties, coked
specimens from magnesia-carbon and impregnated burned
modulus of rupture, and thermal expansion.
basicbrick.Thispracticegenerallyconcernspreparationoftest
specimens from brick greater than 13 in. (33 cm) in length. 3.2 This practice does not specify specific sample sizes. For
These brick are mainly manufactured for use in electric arc specific sample sizes, the particular ASTM test of interest
furnaces and basic oxygen furnaces. should be consulted.
1.2 The values stated in inch-pound units are to be regarded
4. Significance and Use
as standard. The values given in parentheses are mathematical
4.1 This practice defines a procedure that ensures reason-
conversions to SI units that are provided for information only
ably consistent preparation of specimens for product testing
and are not considered standard.
and evaluation.
1.3 This standard does not purport to address all of the
4.2 This practice can be used in the laboratories of
safety concerns, if any, associated with its use. It is the
producers, users, and general interest parties for research and
responsibility of the user of this standard to establish appro-
development or quality control work. It is particularly useful
priate safety and health practices and determine the applica-
for interlaboratory comparisons on products, for repetitive
bility of regulatory limitations prior to use.
evaluations or comparisons of products or product quality, and
2. Referenced Documents
in specifying a uniform preparation practice for specimens for
2.1 ASTM Standards: acceptance testing.
C607Practice for Coking Large Shapes of Carbon-Bearing
4.3 If pitch impregnated samples are prepared by wet
Materials
cutting or drilling, care should be taken in drying them. If the
C830 Test Methods for Apparent Porosity, Liquid
samples are heated to facilitate drying, the temperature to
Absorption, Apparent Specific Gravity, and Bulk Density
which they are heated should not be so high that it causes
of Refractory Shapes by Vacuum Pressure
drainage of pitch from the samples.
C831Test Methods for Residual Carbon,Apparent Residual
4.4 Porosities of metal-containing brick must be measured
Carbon, and Apparent Carbon Yield in Coked Carbon-
using kerosene or mineral spirits because using water will
Containing Brick and Shapes
result in an artificially low result.
C1099Test Method for Modulus of Rupture of Carbon-
ContainingRefractoryMaterialsatElevatedTemperatures
5. Apparatus
3. Summary of Practice
5.1 Saw or Drill, appropriate for cutting dense refractory
shapes.
3.1 This practice defines a procedure for obtaining samples
fromcarbon-containingbasicbrick.Thesesamplescanbeused
6. Procedure
ThispracticeisunderthejurisdictionofASTMCommitteeC08onRefractories
6.1 First break the as-received brick across its width in a
and is the direct responsibility of Subcommittee C08.92The Joseph E. Kopanda
three-point modulus of rupture test as indicated in Fig. 1. Note
Subcommittee for Editorial, Terminology and Classification.
that for a 30-in. (76-cm) long brick, the cold modulus of
Current edition approved Nov. 1, 2010. Published Nove
...







Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.