Standard Specification for Linoleum Floor Tile

ABSTRACT
This specification covers floor tiles made of a homogeneous mixture of linoleum cement binder calendered or pressed onto a fibrous or suitable backing for use in commercial, light commercial and residential buildings based on serviceability characteristics. General information and performance characteristics, which determine serviceability and recommended use, are included in this document. The floor coverings shall be of the following types: Type I—linoleum floor tile with fibrous backing; Type II—linoleum floor tile with special backing; Type III—linoleum floor tile without backing; and Type IV—static dissipative linoleum floor tile with or without backing. Materials shall be tested and the individual grades shall conform to specified values of physical properties such as wear surface, size, thickness, and squareness; performance requirements such as residual indentation, static load resistance, flexibility, dimensional stability, resistance to chemicals, resistance to heat, resistance to light, and static dissipation.
SCOPE
1.1 This specification covers floor tiles made of a homogeneous mixture of linoleum cement binder calendered or pressed onto a fibrous or suitable backing. This specification also covers linoleum floor tile without backing.  
1.2 Four types of linoleum floor tile are covered. The floor covering is intended for use in commercial, light commercial, and residential buildings based on serviceability characteristics. General information and performance characteristics, which determine serviceability and recommended use, are included in this document.  
1.3 The following safety hazards caveat pertains only to the test methods portion, Sections 7 and 8, of this specification.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-Aug-2018
Drafting Committee
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM F2195-18 - Standard Specification for Linoleum Floor Tile
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F2195-18 - Standard Specification for Linoleum Floor Tile
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F2195 − 18
Standard Specification for
1
Linoleum Floor Tile
This standard is issued under the fixed designation F2195; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope F141 Terminology Relating to Resilient Floor Coverings
F150 Test Method for Electrical Resistance of Conductive
1.1 This specification covers floor tiles made of a homoge-
and Static Dissipative Resilient Flooring
neous mixture of linoleum cement binder calendered or pressed
F386 Test Method for Thickness of Resilient Flooring Ma-
onto a fibrous or suitable backing. This specification also
terials Having Flat Surfaces
covers linoleum floor tile without backing.
F410 Test Method for Wear Layer Thickness of Resilient
1.2 Four types of linoleum floor tile are covered. The floor
Floor Coverings by Optical Measurement
covering is intended for use in commercial, light commercial,
F925 Test Method for Resistance to Chemicals of Resilient
and residential buildings based on serviceability characteris-
Flooring
tics. General information and performance characteristics,
F970 Test Method for Measuring Recovery Properties of
which determine serviceability and recommended use, are
Floor Coverings after Static Loading
included in this document.
F1514 Test Method for Measuring Heat Stability of Resilient
Flooring by Color Change
1.3 The following safety hazards caveat pertains only to the
test methods portion, Sections 7 and 8, of this specification. F1515 Test Method for Measuring Light Stability of Resil-
ient Flooring by Color Change
1.4 This standard does not purport to address all of the
F2055 Test Method for Size and Squareness of Resilient
safety concerns, if any, associated with its use. It is the
Floor Tile by Dial Gage Method
responsibility of the user of this standard to establish appro-
2.2 Other Standards:
priate safety, health, and environmental practices and deter-
ANSI/ASQC Z1.4 Sampling Procedures and Tables for In-
mine the applicability of regulatory limitations prior to use.
3
spection by Attributes
1.5 The values stated in inch-pound units are to be regarded
EN 669 Determination of the Dimensional Changes of Tiles
as standard. The values given in parentheses are mathematical
4
Caused by Atmospheric Humidity Changes
conversions to SI units that are provided for information only
ISO 24343-1 Determination of Indentation and Residual
and are not considered standard.
Indentation – Part 2: Short-Term Residual Indentation of
1.6 This international standard was developed in accor-
5
Resilient Floor Covering
dance with internationally recognized principles on standard-
ISO 26985 Identification of Linoleum and Determination of
ization established in the Decision on Principles for the
5
Cement Content and Ash Residue
Development of International Standards, Guides and Recom-
mendations issued by the World Trade Organization Technical
3. Terminology
Barriers to Trade (TBT) Committee.
3.1 Definitions:
3.1.1 For definitions, refer to Terminology F141.
2. Referenced Documents
2
2.1 ASTM Standards:
4. Classification
F137 Test Method for Flexibility of Resilient Flooring Ma-
4.1 The floor coverings shall be of the following types:
terials with Cylindrical Mandrel Apparatus
4.1.1 Type I—Linoleum floor tile with fibrous backing.
4.1.2 Type II—Linoleum floor tile with special backing.
1
4.1.3 Type III—Linoleum floor tile without backing.
This specification is under the jurisdiction of ASTM Committee F06 on
Resilient Floor Coverings and is the direct responsibility of Subcommittee F06.80
on Specifications.
3
Current edition approved Sept. 1, 2018. Published October 2018. Originally Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
approved in 2002. Last previous edition approved in 2013 as F2195–13. DOI: 4th Floor, New York, NY 10036.
4
10.1520/F2195-18. Available from CEN European Committee for Standardization—Central Sec-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or retariat: rue de Stassart, 36 B-1050 Brussels.
5
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Available from International Organization for Standardization (ISO), ISO
Standards volume information, refer to the standard’s Document Summary page on Central Secretariat, BIBC II, Chemin de Blandonnet 8, CP 401, 1214 Vernier,
the ASTM website. Geneva, Switzerland, http://www.iso.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2195 − 18
4.1.4 Type IV—Stati
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2195 − 13 F2195 − 18
Standard Specification for
1
Linoleum Floor Tile
This standard is issued under the fixed designation F2195; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers floor tiles made of a homogeneous mixture of linoleum cement binder calendered or pressed onto
a fibrous or suitable backing. This specification also covers linoleum floor tile without backing.
1.2 Four types of linoleum floor tile are covered. The floor covering is intended for use in commercial, light commercial, and
residential buildings based on serviceability characteristics. General information and performance characteristics, which determine
serviceability and recommended use, are included in this document.
1.3 The following safety hazards caveat pertains only to the test methods portion, Sections 7 and 8, of this specification.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory requirementslimitations prior to use.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
F137 Test Method for Flexibility of Resilient Flooring Materials with Cylindrical Mandrel Apparatus
F141 Terminology Relating to Resilient Floor Coverings
F150 Test Method for Electrical Resistance of Conductive and Static Dissipative Resilient Flooring
F386 Test Method for Thickness of Resilient Flooring Materials Having Flat Surfaces
F410 Test Method for Wear Layer Thickness of Resilient Floor Coverings by Optical Measurement
F925 Test Method for Resistance to Chemicals of Resilient Flooring
F970 Test Method for Measuring Recovery Properties of Floor Coverings after Static Loading
F1514 Test Method for Measuring Heat Stability of Resilient Flooring by Color Change
F1515 Test Method for Measuring Light Stability of Resilient Flooring by Color Change
F2055 Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method
2.2 Other Standards:
3
ANSI/ASQC Z1.4 Sampling Procedures and Tables for Inspection by Attributes
4
EN 433 Determination of Residual Indentation after Static Loading
4
EN 669 Determination of the Dimensional Changes of Tiles Caused by Atmospheric Humidity Changes
ISO 24343-1 Determination of Indentation and Residual Indentation – Part 2: Short-Term Residual Indentation of Resilient Floor
5
Covering
1
This specification is under the jurisdiction of ASTM Committee F06 on Resilient Floor Coverings and is the direct responsibility of Subcommittee F06.80 on
Specifications.
Current edition approved Nov. 1, 2013Sept. 1, 2018. Published December 2013October 2018. Originally approved in 2002. Last previous edition approved in 20072013
as F2195–07.–13. DOI: 10.1520/F2195-13.10.1520/F2195-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.
4
Available from CEN European Committee for Standardization—Central Secretariat: rue de Stassart, 36 B-1050 Brussels.
5
Available from International Organization for Standardization (ISO), ISO Central Secretariat, BIBC II, Chemin de Blandonnet 8, CP 401, 1214 Vernier, Geneva,
Switzerland, http://www.iso.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2195 − 18
EN 670ISO 26985 Identification of
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.