Standard Test Method for Reheat Change of Refractory Brick

SCOPE
1.1 This test method covers the determination of the permanent linear change of refractory brick when heated under prescribed conditions.  
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.  Note 1-Test methods incorporating additional provisions pertinent to specific refractory materials are given in the following Test Methods: C179, C210, C436, and C605.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Mar-1998
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C113-93(1998) - Standard Test Method for Reheat Change of Refractory Brick
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
Designation: C 113 – 93 (Reapproved 1998)
Standard Test Method for
Reheat Change of Refractory Brick
This standard is issued under the fixed designation C 113; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope reheating. This test method provides a standard procedure for
heating various classes of refractories with appropriate heating
1.1 This test method covers the determination of the perma-
schedules.
nent linear change of refractory brick when heated under
3.2 Linear reheat changes obtained by this test method are
prescribed conditions.
suitable for use in research and development, also often used to
1.2 The values stated in inch-pound units are to be regarded
establish written specifications between producers and con-
as the standard. The values given in parentheses are for
sumers.
information only.
3.3 Care should be exercised in selecting samples that are
NOTE 1—Test methods incorporating additional provisions pertinent to
representative of the product being tested and that the schedule
specific refractory materials are given in the following Test Methods: C
selected is appropriate to the product.
179, C 210, C 436, and C 605.
1.3 This standard does not purport to address all of the 4. Apparatus
safety concerns, if any, associated with its use. It is the
4.1 Kiln, of such design that the specified heating schedule
responsibility of the user of this standard to establish appro-
and atmosphere can be maintained throughout the heating
priate safety and health practices and determine the applica-
zone.
bility of regulatory limitations prior to use.
4.2 Linear Measuring Device, capable of being read to 0.02
in. (0.5 mm) over a span of 10 in. (254 mm). A hook-rule, as
2. Referenced Documents
specified in Test Methods C 134, a vernier caliper, or a dial
2.1 ASTM Standards:
gage device may be used.
C 134 Test Methods for Size, Dimensional Measurements,
4.3 Gas Sampling and Analysis Equipment, capable of
and Bulk Density of Refractory Brick and Insulating
determining the percent free oxygen and total combustibles in
Firebrick
the atmosphere of the test chamber.
C 179 Test Method for Drying and Firing Linear Change of
Refractory Plastic and Ramming Mix Specimens 5. Test Specimens
C 210 Test Method for Reheat Change of Insulating Fire-
5.1 For each test use three rectangular specimens measuring
brick 1 1
9by4 ⁄2 by 2 ⁄2 or 3 in. (228 by 114 by 64 or 76 mm) in size,
C 436 Method ofTest for Reheat Change of Carbon Refrac-
or, if smaller, shapes approaching these dimensions as closely
tory Brick and Shapes
as possible. These may be commercial brick of the specified
C 605 Test Method for Reheat Change of Fireclay Nozzles
size or test pieces cut out of larger shapes.
and Sleeves
5.2 Using ceramic paint or crayon, label each specimen, and
E 230 Temperature-Electromotive Force (EMF) Tables for
make a reference mark at each end on the center line of a broad
Standardized Thermocouples
face to indicate the exact position where the measurement is
made. Measure the length on each of the three test specimens
3. Significance and Use
to the nearest 0.02 in. (0.5 mm).
3.1 Refractory brick and shapes of different compositions
6. Procedure
exhibit unique permanent linear changes after heating or
6.1 Placing Specimens in Kiln—Place the test specimens in
the kiln so that each rests edgewise, that is, ona9by2 ⁄2 or
This test method is under the jurisdiction of ASTM Committee C-8 on
3-in. (228 by 64 or 76-mm) face and set only one course high.
Refractories and is the direct responsibility of Subcommittee C08.03 on Physical
Tests. Place each specimen upon the corresponding face of a support-
Current edition approved March 15, 1993. Published May 1993. Originally
ing brick that is from the same lot as the test specimen or at
published as C 113 – 34 T. Last previous edition C 113 – 87.
2 least of equal refractoriness. Place between the test specimen
Annual Book of ASTM Standards, Vol 15.01.
and the supporting brick a layer of suitable refractory material,
Annual Book of ASTM Standards, Vol 14.03.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
C 113 – 93 (1998)
TABLE 1 Heating Schedule for Reheat of Various Types of Refractories
Allowable
Temperature of Test Specimen, °F (°C) (The highest temperature in each schedule shall be maintained for 5 h)
Elapsed Time Deviation
from Start of from
Heating, h Schedule,
Schedule A Schedule B Schedule C Schedule D Schedule E Schedule F Schedule G Schedule H
6°F (6°C)
1 50 (28) 1380 (750) 1740 (950) 1740 (950) 1605 (875) 1500 (815) 1740 (950) 1740 (950) 1740 (950)
2 25 (14) 2010 (1100) 2370 (1300) 2370 (1300) 2280 (1250) 2230 (1220) 2370 (1300) 2370 (1300) 2370 (1300)
3 15 (8.5) 2190 (1200) 2550 (1400) 2685 (1475) 2460 (1350) 2350 (1290) 2640 (1450) 2685 (1475) 2685 (1475)
4 15 (8.5) . .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.