Thermal insulation products for buildings - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 2: Specification for the installed products

This European Standard specifies the requirements for the four types of exfoliated vermiculite products Vermiculite Aggregate (EVA), Coated Vermiculite (EVC), Hydrophobic Vermiculite (EVH) and Premixed Vermiculite (EVM), containing less than 1 % organic material as defined by Annex D of EN14317-1:2004 for in-situ insulation of roofs, ceilings, walls and floors.
This Part 2 of the standard is a specification for the installed products.
This Part 2 of this standard also specifies the checks and test procedures to be used for the declaration made by the installer of the product.
This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards.
This European Standard does not include factory made insulation products of formed shapes and boards made with exfoliated vermiculite or in-situ products intended to be used for the insulation of building equipment and industrial installations.
This European Standard does not specify performance requirements for airborne sound insulation and for acoustic absorption applications.

Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung mit Produkten aus expandiertem Vermiculit (EV) - Teil 2: Spezifikation für die eingebauten Produkte

Diese Europäische Norm legt Anforderungen an vier Arten von Wärmedämmprodukten aus expandiertem
Vermiculit fest, die an der Verwendungsstelle zur Wärmedämmung von Dächern, Decken, Wänden und
Fußböden hergestellt werden und entsprechend der Definition in Anhang D von EN 14317-1:2004 weniger als
1 % organische Stoffe enthalten; die vier Vermiculitprodukte sind Vermiculitkörner (Vermiculite Aggregate,
EVA), beschichtetes Vermiculit (Coated Vermiculite, EVC), wasserabweisendes Vermiculit (Hydrophobic
Vermiculite, EVH) und vorgemischtes Vermiculit (Premixed Vermiculite, EVM).
Der vorliegende Teil 2 dieser Norm ist eine Spezifikation für die eingebauten Produkte.
Teil 2 dieser Norm legt außerdem die Überprüfungen und Prüfverfahren fest, die für die vom Monteur für das
Produkt abzugebende Erklärung anzuwenden sind.
Diese Europäische Norm legt keine Anforderungsstufen für eine bestimmte Eigenschaft fest, die ein Produkt
erreichen muss, um für einen bestimmten Anwendungszweck gebrauchstauglich zu sein. Die erforderlichen
Stufen sind Vorschriften oder übereinstimmenden Normen zu entnehmen.
Diese Europäische Norm gilt nicht für fabrikmäßig hergestellte, in vorgefertigten Formen oder als Platten
vorliegende Wärmedämmstoffe aus expandiertem Vermiculit oder für an der Verwendungsstelle hergestellte
Produkte, die für Anwendungen zur Dämmung von haustechnischen und betriebstechnischen Anlagen
vorgesehen sind.
In dieser Europäischen Norm werden keine Leistungsanforderungen an die Luftschalldämmung und an die
Schallabsorption festgelegt.

Produits isolants thermiques pour le bâtiment - Isolation thermique formée en place à base de granulats légers de vermiculite exfoliée - Partie 2: Spécification des produits mis en place

La présente Norme européenne spécifie les exigences concernant quatre types de produits à base de vermiculite exfoliée : les granulats de vermiculite (EVA), la vermiculite enrobée (EVC), la vermiculite hydrophobe (EVH) et la vermiculite prémélangée (EVM), contenant moins de 1 % de matériaux organiques selon la définition de l’Annexe D de l’EN 14317 1:2004, et destinés à l’isolation en place des toitures, des plafonds, des murs et des planchers.
Le présent document est une spécification applicable aux produits installés.
Il décrit également les vérifications et les modes opératoires d’essai nécessaires pour la déclaration de l’installateur du produit.
La présente Norme européenne ne spécifie pas le niveau requis de toutes les propriétés requises pour qu’un produit démontre son aptitude à l’emploi dans une application particulière. Les niveaux requis peuvent être trouvés dans des réglementations ou dans des normes non-divergentes.
La présente norme européenne n’inclut pas des produits d’isolation formés fabriqués en usine ni les panneaux à base de vermiculite exfoliée ou les produits formés en place, destinés à l’isolation d’équipements de bâtiments et d’installations industrielles.
Le présent document ne spécifie pas d’exigences de performance pour les applications d’isolement aux bruits aériens et d’absorption acoustique.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz razplastenega vermikulita (EV), oblikovani na mestu vgradnje - 2. del: Specifikacija za vgrajene izolacijske proizvode

General Information

Status
Published
Publication Date
30-Jan-2007
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
05-Oct-2020

Buy Standard

Standard
EN 14317-2:2007
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Thermal insulation products for buildings - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 2: Specification for the installed productsToplotnoizolacijski proizvodi za stavbe - Proizvodi iz razplastenega vermikulita (EV), oblikovani na mestu vgradnje - 2. del: Specifikacija za vgrajene izolacijske proizvodeProduits isolants thermiques pour le bâtiment - Isolation thermique formée en place a base de granulats légers de Vermiculite exfoliée (EV) - Partie 2: Spécification des produits mis en placeWärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung mit Produkten aus expandiertem Vermiculit (EV) - Teil 2: Spezifikation für die eingebauten ProdukteTa slovenski standard je istoveten z:EN 14317-2:2007SIST EN 14317-2:2007en;de91.100.60Thermal and sound insulating materialsICS:SLOVENSKI
STANDARDSIST EN 14317-2:200701-julij-2007

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14317-2January 2007ICS 91.100.60 English VersionThermal insulation products for buildings - In-situ thermalinsulation formed from exfoliated vermiculite (EV) products - Part2: Specification for the installed productsProduits isolants thermiques pour le bâtiment - Isolationthermique formée en place à base de granulats légers deVermiculite exfoliée (EV) - Partie 2: Spécification desproduits mis en placeWärmedämmstoffe für Gebäude - An derVerwendungsstelle hergestellte Wärmedämmung mitProdukten aus expandiertem Vermiculit (EV) - Teil 2:Spezifikation für die eingebauten ProdukteThis European Standard was approved by CEN on 2 December 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14317-2:2007: E

Suitability of the building and the insulation product.7 Bibliography.8

1 Scope This European Standard specifies the requirements for the four types of exfoliated vermiculite products Vermiculite Aggregate (EVA), Coated Vermiculite (EVC), Hydrophobic Vermiculite (EVH) and Premixed Vermiculite (EVM), containing less than 1 % organic material as defined by Annex D of EN 14317-1:2004 for in-situ insulation of roofs, ceilings, walls and floors. This Part 2 of the standard is a specification for the installed products. This Part 2 of this standard also specifies the checks and test procedures to be used for the declaration made by the installer of the product. This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards. This European Standard does not include f
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.