EN 1462:2004
(Main)Brackets for eaves gutters - Requirements and testing
Brackets for eaves gutters - Requirements and testing
This document specifies the requirements for rafter and fascia board brackets intended to support eaves gutters conforming to EN 607 or EN 612.
Rinnenhalter für Hängedachrinnen - Anforderungen und Prüfung
Dieses Dokument legt die Anforderungen an Dach und Frontrinnenhalter fest, die zur Befestigung von Hängedachrinnen nach EN 607 oder EN 612 dienen.
Crochets de gouttières pendantes - Exigences et méthodes d'essai
La présente Norme spécifie les exigences applicables aux crochets chevron et aux crochets bandeau destinés à supporter les gouttières pendantes conformes à l'EN 607 ou à l'EN 612.
Nosilci žlebov - Zahteve in preskušanje
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Nosilci žlebov - Zahteve in preskušanjeRinnenhalter für Hängedachrinnen - Anforderungen und PrüfungCrochets de gouttieres pendantes - Exigences et méthodes d'essaiBrackets for eaves gutters - Requirements and testing91.060.20StreheRoofsICS:Ta slovenski standard je istoveten z:EN 1462:2004SIST EN 1462:2004en01-december-2004SIST EN 1462:2004SLOVENSKI
STANDARDSIST EN 1462:19981DGRPHãþD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1462September 2004ICS 91.060.20Supersedes EN 1462:1997
English versionBrackets for eaves gutters - Requirements and testingCrochets de gouttières pendantes - Exigences et méthodesd'essaiRinnenhalter für Hängedachrinnen - Anforderungen undPrüfungThis European Standard was approved by CEN on 15 July 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2004 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1462:2004: ESIST EN 1462:2004
General.7 6.2
Load bearing capacity.7 6.3
Holes for fastenings.8 7 Designation of gutter brackets for ordering purposes.8 8 Marking.8 9 Production control.9 Annex A (normative)
Test method to determine the corrosion resistance of plastic-coated gutter brackets.10 A.1 Principle.10 A.2 Apparatus.10 A.3 Procedure.10 Annex B (normative)
Test method to determine the load bearing capacity of gutter brackets.12 B.1 Principle.12 B.2 Apparatus.12 B.3 Procedure.12
Zinc coatings shall conform to the minimum values given in Table 1. b) Flexible plastic coating, ≥ 60 µm thick, over a zinc coating with an average thickness of ≥ 20 µm. c) Flexible plastic coating, ≥ 60 µm thick, with a suitable substrate. When tested in accordance with Annex A, the plastic-coated bracket shall not exhibit any signs of rust or loosening of the coating from the steel. Table 1 — Minimum zinc coating for mild steel brackets hot-dip galvanized after manufacture Thickness of coating Steel thickness of bracket
αααα
(mm) Minimum single value (µm) Average value
(µm) α > 6 70 85 6
≥ α > 3 55 70 3
≥ α
> 1,5 45 55
5.2 Gutter brackets of PVC-U shall meet the artificial ageing and colour-fastness requirements detailed in EN 607.
5.3 Gutter brackets shall be manufactured from corrosion-resistant materials according to whether they are intended for use in aggressive atmospheres (Class A – industrial pollution or maritime) or more benign conditions (Class B), as given in Table 2.
Table 2 — Classes of resistance to corrosion Material of manufacture Class of resistance to corrosion Stainless steel, copper, rolled or wrought aluminium or mild steel coated in accordance with 5.1 a) or b) A Cast aluminium conforming to EN 1706, with a corrosion resistance grading of A to C inclusive
A Cast aluminium conforming to EN 1706, corrosion resistance coated in accordance with 5.1c) A PVC-U, conforming to EN 607 A Uncoated cast aluminium conforming to EN 1706, with a corrosion resistance of grade D B Mild steel conforming to EN 10025 or EN 10111, coated in accordance with 5.1c), or hot-dip coated mild steel conforming to EN 10142, EN 10326, EN 10327 or EN 10215 B
Design 6.1
General Gutter brackets shall be of such dimensions that the gutters of the shape and size for which they are designed can slide freely through them. It shall not be possible for gutters to be lifted out of a bracket by strong wind. This shall be achieved either through the design of integral lugs or nibs on the bracket itself or by providing separate clips or springs to attach the gutter to the bracket. Clips and springs are not required to be of the same material as the bracket to which they are attached, but shall have a corrosion resistance of Class A, as given in Table 2, if attached to a gutter bracket of corrosion resistance Class A. Clips and springs shall be manufactured from one of the following materials: any of the materials specified in Clause 4; polyamide plastic; galvanized and prepainted steel sheet having an average coating mass of not less than 275 g/m2. Where both the clip or spring and the gutter bracket are manufactured from metal, care shall be taken to avoid contact between incompatible metals, thereby reducing the risk of electrolytic corrosion. 6.2
Load bearing capacity Gutter brackets shall be divided into three classes according to their load bearing capacity. When tested in accordance with Annex B, brackets of 80 mm or greater top opening width (i.e. brackets of Classes H and L) shall support the loads given in Table 3 without collapse and without causing permanent deflection exceeding 5 mm at the outer end of the bracket. SIST EN 1462:2004
(N) Load bearing Class Brackets for heavy duty 750 H Brackets for light duty 500 L Brackets for gutters below 80 mm top opening width O
6.3
Holes for fastenings Rafter brackets shall have not less than two holes for fastenings. Where these brackets are designed to be fixed either by nails or screws, the holes shall not be less than 12 x (hole diameter) apart. Where the bracket is designed to be fixed only by screws, the holes shall not be less than seven diameters apart and the bracket shall be marked “S”.
Fascia brackets of the heavy-duty load-beari
...