This European standard specifies the requirements for brackets intended to sup- port eaves gutters conforming to EN 607 or prEN 612
Rinnenhalter für Hängedachrinnen - Anforderungen und Prüfung
Diese Europäische Norm legt die Anforderungen für Rinnenhalter fest, die zur Besfestigung von Hängedachrinnen nach EN 607 oder prEN 612 dienen.
Crochets de gouttières - Exigences et méthodes d'essai
La présente norme européenne prescrit les exigences pour les crochets destinés àsupporter les gouttières pendantes selon l'EN 607 et l'EN 612.
Nosilci žlebov - Zahteve in preskušanje
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Nosilci žlebov - Zahteve in preskušanjeRinnenhalter für Hängedachrinnen - Anforderungen und PrüfungCrochets de gouttieres - Exigences et méthodes d'essaiBrackets for eaves gutters - Requirements and testing91.060.20StreheRoofsICS:Ta slovenski standard je istoveten z
...
This May Also Interest You
This document characterizes waste water or rain water piping systems as airborne sound source and structure-borne sound source using the same method as the one described in EN 15657 for characterizing building service equipment. It therefore applies to equipment installed in any type of buildings (heavy or lightweight).
This document:
- specifies laboratory measuring methods for determining the input data required for both comparing products and materials, and predicting sound levels in buildings using EN 12354 5. These input quantities are the piping system sound power level for airborne sound and three quantities for structure-borne sound (piping system free velocity, blocked force and mobility), from which the piping system installed power, source input for EN 12354 5, is determined;
- specifies the method for the measurement of the equipment airborne sound power;
- only considers piping systems connected to one supporting building element in a first step;
NOTE Simultaneous structure-borne transmissions to wall and floor are more difficult to handle. In the configurations proposed in this document, the piping system is only connected to one supporting element and mechanically decoupled from the other elements.
- includes configurations of vertical pipes with offset (deviated horizontally) connected to walls and horizontal pipes connected to ceilings, for which the measuring method is the same as the one defined for straight vertical pipes connected to walls. These complementary configurations are described in (normative) Annex A;
- specifies laboratory test procedures for determining the performance of mitigation measures such as pipe enclosures (technical shaft) and pipe lining. The corresponding specifications are given in (normative) Annex B;
- defines the expression of the results for use in comparing products and materials and for use as input data for prediction; however, the Single Number Quantities used to compare products cannot be used as a prediction or proof of compliance with requirements in a building;
- indicates a method to transform the quantities measured according to EN 14366:2004+A1:2019, to the quantities used in this document; however, the calculated values cannot be used as certified values obtained by test, but only for comparison with new tests. This method is given in (informative) Annex C.
This document is applicable to waste water piping systems and parts thereof, but not to the actual sources of waste water, e.g. lavatories, toilets and bathtubs or any active units, which are considered separately in EN 12354 5 and are characterized separately. It applies to pipes with natural ventilation and made of any common material in commonly used diameters (up to 150 mm).
- Draft31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-Jul-2023
- 17.140.20
- 91.140.80
- CEN/TC 126
This Technical Specification gives guidance on the assessment of conformity of GRP-UP (glass-reinforced thermosetting resins based on unsaturated polyesters) piping products and assemblies in accordance with EN 1796 and EN 14364 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures. This Technical Specification also gives guidance on the assessment of conformity of GRP-UP manholes and inspection chambers in accordance with prEN 15383. Pipes according to EN 14364 are used for manufacturing the shafts and chamber units. Additional statements as needed to assess the conformity of manholes and inspection chambers are given in Annex F. NOTE 1 It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [3]. NOTE 2 If third-party certification is involved, it is recommended that the certification body is accredited to EN 45011 [1], EN 45012 [2] or EN ISO/IEC 17021 [5], as applicable.
- Technical specification39 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft39 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Jun-2023
- 23.040.05
- 91.140.60
- 91.140.80
- 93.030
- CEN/TC 155
This document specifies methods of test for the resistance of the base of thermoplastics inspection chambers and manholes to external soil and ground-water pressure after installation.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft15 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Jan-2023
- 23.040.20
- 23.040.45
- 91.140.80
- 93.030
- CEN/TC 155
This document specifies a test method for assessing the initial (short-term) tangential ring stiffness of riser shafts for thermoplastics inspection chambers or manholes.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Jan-2023
- 23.040.20
- 23.040.45
- 91.140.80
- 93.030
- CEN/TC 155
This document specifies a method of testing the resistance of the upper assembly of inspection chambers and manhole components against surface and traffic loading.
It is not applicable to requirements for testing the cover and frame. Those requirements are specified in EN 124-1 or other standards, depending on the material.
NOTE Upper assembly components normally include shafts or risers, cones, telescopic adapters and near surface components.
- Standard13 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Jan-2023
- 23.040.20
- 23.040.45
- 91.140.80
- 93.030
- CEN/TC 155
This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of chlorinated poly(vinyl chloride) (PVC-C) piping systems intended for soil and waste discharge (low and high temperature):
- inside buildings (application area code “B”);
- for both inside buildings and buried in ground within the building structure (application area code “BD”).
NOTE 1 The intended use is reflected in the marking of products by “B” or “BD”.
NOTE 2 Application “B” covers uses above ground inside buildings, or outside buildings fixed onto the wall.
NOTE 3 Pipes and fittings of the pipe series S 25 are intended to be used for application area “B” only.
NOTE 4 For use buried in ground within the building structure are intended only those components (marked with “BD”) with nominal outside diameters equal to or greater than 75 mm.
NOTE 5 EN 476 [5] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this document fully meet these requirements.
This document is applicable to PVC-C pipes and fittings and the system intended for the following purposes:
- ventilating part of the pipework in association with discharge applications;
- rainwater pipework within the building structure.
It also specifies the test parameters for the test methods that are referred to.
This document covers a range of nominal sizes, a range of pipe series and gives recommendations concerning colours.
NOTE 6 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 7 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex A can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 21.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft39 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Dec-2022
- 23.040.01
- 91.140.80
- 305/2011
- CEN/TC 155
This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of acrylonitrile-butadiene-styrene (ABS) and acrylonitrile-styrene-acrylester (ASA) piping systems intended for soil and waste discharge applications (low and high temperature):
- inside buildings (application area code “B”);
- for both inside buildings and buried in ground within the building structure (application area code “BD”).
NOTE 1 The intended use is reflected in the marking of products by “B” or “BD”.
NOTE 2 Application “B” covers uses above ground inside buildings, or outside buildings fixed onto the wall.
NOTE 3 Pipes and fittings of the pipe series S 25 are intended to be used for application area “B” only.
NOTE 4 For use buried in ground within the building structure are intended only those components (marked with “BD”) with nominal outside diameters equal to or greater than 75 mm.
NOTE 5 EN 476 [5] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this document fully meet these requirements.
This document is also applicable to ABS and ASA pipes, fittings and the system intended for the following purposes:
- ventilating part of the pipework in association with discharge applications;
- rainwater pipework within the building structure.
It also specifies the test parameters for the test methods that are referred to.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
NOTE 6 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 7 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex A can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 21.
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft40 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Dec-2022
- 23.040.01
- 91.140.80
- CEN/TC 155
This document classifies floor gullies for domestic wastewater for use inside buildings, gives guidance, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking of factory made gullies for buildings, irrespective of the material, for use in drainage systems requiring a trap with combined mechanical closure and water seal (referred to as floor gullies).
NOTE Floor gullies with combined mechanical closure and water seal are not covered by EN 1253-1, EN 1253-6, EN 1253-7.
These products are intended to be installed where both condition below are fulfilled:
- the building does not exceed a ground-floor and three floors above;
- infrequent use could result in a water seal evaporating.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-Oct-2022
- 91.140.80
- CEN/TC 165
This document classifies floor gullies for domestic waste water for use inside buildings, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking of factory made gullies for buildings, irrespective of the material, for use in drainage systems requiring a trap with a depth of water seal less than 50 mm (referred to as floor gullies).
NOTE Floor gullies with a depth of water seal less than 50 mm are not covered by EN 1253 1, EN 1253 7 and EN 1253 8.
These products are intended to be installed where the three following conditions are met:
- space limitation will not accommodate a gully with a 50 mm water seal;
- the building does not exceed a ground-floor and three floors above;
- at least two domestic sanitary appliances are installed in addition to the gully but with only one WC on the same branch (connection pipe) or secondary or branch ventilation is installed (see EN 12056 2:2000, 4.3.2 or 4.3.4.
- Standard30 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft28 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-Oct-2022
- 91.140.80
- CEN/TC 165
This document classifies floor gullies for domestic waste water for use inside buildings, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking of factory made gullies for buildings, irrespective of the material, for use in drainage systems requiring a trap with a mechanical closure (referred to as floor gullies).
NOTE Floor gullies with a depth of water seal less than 50 mm are not covered by EN 1253-1, EN 1253-7 and EN 1253-8.
These products are intended to be installed where both conditions below are fulfilled:
- the building does not exceed a ground-floor and three floors above;
- infrequent use could result in a water seal evaporating.