EN ISO 11206:2013
(Main)Water quality - Determination of dissolved bromate - Method using ion chromatography (IC) and post column reaction (PCR) (ISO 11206:2011)
Water quality - Determination of dissolved bromate - Method using ion chromatography (IC) and post column reaction (PCR) (ISO 11206:2011)
ISO 11206:2011 specifies a method for the determination of dissolved bromate in water (e.g. drinking water, mineral water, raw water, surface water, partially treated water or swimming pool water).
Appropriate pretreatment of the sample (e.g. dilution) allows determination of bromate at concentrations ³0,5 µg/l.
The working range is restricted by the ion‑exchange capacity of the separator column. Dilution of the sample to the bromate working range can be necessary.
Wasserbeschaffenheit - Bestimmung von gelöstem Bromat - Verfahren mittels Ionenchromatographie (IC) und Nachsäulenreaktion (PCR) (ISO 11206:2011)
Diese Internationale Norm legt ein Verfahren zur Bestimmung von gelöstem Bromat in Wasser (z. B. Trinkwasser, Mineralwasser, Rohwasser, Oberflächenwasser, teilweise behandeltes Wasser oder Badewasser) fest.
Eine geeignete Probenvorbehandlung (z. B. Verdünnung) erlaubt die Bestimmung von Bromatkonzentrationen ≥ 0,5 µg/l.
Der Arbeitsbereich ist durch die Kapazität der Trennsäule begrenzt. Eine Probenverdünnung in den Arbeitsbereich kann erforderlich sein.
Qualité de l'eau - Dosage du bromate dissous - Méthode utilisant la chromatographie ionique (IC) et la réaction post-colonne (PCR) (ISO 11206:2011)
L'ISO 11206:2011 spécifie une méthode pour le dosage du bromate dissous dans l'eau (par exemple l'eau potable, l'eau minérale, l'eau brute, les eaux de surface, l'eau partiellement traitée ou l'eau de piscine).
Le prétraitement approprié de l'échantillon (par exemple dilution) permet de doser le bromate à des concentrations supérieures ou égales à 0,5 µg/l.
Le domaine de travail est limité à la capacité d'échange ionique de la colonne de séparation. Il peut être nécessaire de diluer l'échantillon dans le domaine de travail du bromate.
Kakovost vode - Določevanje raztopljenega bromata - Metoda z ionsko kromatografijo in pokolonsko reakcijo (PCR) (ISO 11206:2011)
Ta mednarodni standard določa metodo za določevanje raztopljenega bromata v vodi (npr. pitna, mineralna, surova, površinska, delno pripravljena ali bazenska voda). Ustrezna predpriprava vzorca (npr. redčenje) omogoča določevanje bromata pri koncentraciji 0,5 μg/l. Delovni obseg je omejen z zmogljivostjo ionske izmenjave separatorske kolone. Morda je potrebno redčenje vzorca do delovnega obsega bromata.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2013
.DNRYRVWYRGH'RORþHYDQMHUD]WRSOMHQHJDEURPDWD0HWRGD]LRQVNR
NURPDWRJUDILMRLQSRNRORQVNRUHDNFLMR3&5,62
Water quality - Determination of dissolved bromate - Method using ion chromatography
(IC) and post column reaction (PCR) (ISO 11206:2011)
Wasserbeschaffenheit - Bestimmung von gelöstem Bromat - Verfahren mittels
Ionenchromatographie (IC) und Nachsäulenreaktion (PCR) (ISO 11206:2011)
Qualité de l'eau - Détermination du bromate dissous - Méthode utilisant la
chromatographie ionique (IC) et la réaction post-colonne (PCR) (ISO 11206:2011)
Ta slovenski standard je istoveten z: EN ISO 11206:2013
ICS:
13.060.50 3UHLVNDYDYRGHQDNHPLþQH Examination of water for
VQRYL chemical substances
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 11206
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2013
ICS 13.060.50
English Version
Water quality - Determination of dissolved bromate - Method
using ion chromatography (IC) and post column reaction (PCR)
(ISO 11206:2011)
Qualité de l'eau - Détermination du bromate dissous - Wasserbeschaffenheit - Bestimmung von gelöstem Bromat
Méthode utilisant la chromatographie ionique (IC) et la - Verfahren mittels Ionenchromatographie (IC) und
réaction post-colonne (PCR) (ISO 11206:2011) Nachsäulenreaktion (PCR) (ISO 11206:2011)
This European Standard was approved by CEN on 10 February 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2013 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11206:2013: E
worldwide for CEN national Members.
Contents Page
Foreword . 3
Foreword
The text of ISO 11206:2011 has been prepared by Technical Committee ISO/TC 147 “Water quality” of the
International Organization for Standardization (ISO) and has been taken over as EN ISO 11206:2013 by
Technical Committee CEN/TC 230 “Water analysis” the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by September 2013, and conflicting national standards shall be
withdrawn at the latest by September 2013.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 11206:2011 has been approved by CEN as EN ISO 11206:2013 without any modification.
INTERNATIONAL ISO
STANDARD 11206
First edition
2011-07-01
Water quality — Determination of
dissolved bromate — Method using ion
chromatography (IC) and post column
reaction (PCR)
Qualité de l’eau — Détermination du bromate dissous — Méthode utilisant
la chromatographie ionique (IC) et la réaction post-colonne (PCR)
Reference number
ISO 11206:2011(E)
©
ISO 2011
ISO 11206:2011(E)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved
ISO 11206:2011(E)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Interferences . 1
4 Principle . 1
5 Reagents . 2
6 Apparatus . 4
7 Quality requirements . 5
7.1 Separator column . 5
7.2 PCR conditions . 6
7.3 Chromatographic and PCR conditions for the chromatogram shown in Figure 3 . 7
7.4 Chromatographic and PCR conditions for the chromatogram shown in Figure 4 . 8
8 Sampling and sample pretreatment . 9
9 Procedure .10
9.1 General .10
9.2 Calibration .10
9.3 Measurement of bromate .10
9.4 Chlorite removal .10
9.5 Validity check of the calibration function . 11
10 Calculation . 11
11 Expression of results . 11
12 Test report . 11
Annex A (informative) Precision data .12
Bibliography .15
ISO 11206:2011(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11206 was prepared by Technical Committee ISO/TC 147, Water quality, Subcommittee SC 2, Physical,
chemical and biochemical methods.
iv © ISO 2011 – All rights reserved
INTERNATIONAL STANDARD ISO 11206:2011(E)
Water quality — Determination of dissolved bromate — Method
using ion chromatography (IC) and post column reaction (PCR)
WARNING — Persons using this International Standard should be familiar with normal laboratory
practice. This standard does not purport to address all of the safety problems, if any, associated with
its use. It is the responsibility of the user to establish appropriate safety and health practices and to
ensure compliance with any national regulatory conditions.
IMPORTANT — It is absolutely essential that tests conducted according to this International Standard
be carried out by suitably trained staff.
1 Scope
This International Standard specifies a method for the determination of dissolved bromate in water (e.g. drinking
water, mineral water, raw water, surface water, partially treated water or swimming pool water).
Appropriate pretreatment of the sample (e.g. dilution) allows determination of bromate at concentrations �0,5 µg/l.
The working range is restricted by the ion-exchange capacity of the separator column. Dilution of the sample
to the bromate working range can be necessary.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 3696, Water for analytical laboratory use — Specification and test methods
ISO 8466-1, Water quality — Calibration and evaluation of analytical methods and estimation of performance
characteristics — Part 1: Statistical evaluation of the linear calibration function
ISO 8466-2, Water quality — Calibration and evaluation of analytical methods and estimation of performance
characteristics — Part 2: Calibration strategy for non-linear second order calibration functions
3 Interferences
Metals present in samples and eluents bind to the resin material of the separator column, resulting in a loss of
performance. Metal ions can be eliminated with the aid of special cation exchangers (see 6.2 and Clause 8, Note 1).
Solid particles and organic compounds (e.g. mineral oils, detergents, and humic acids) shorten the lifetime of
the precolumn and the separator column (see Clause 8, Notes 2 and 3).
Chlorite can interfere with the determination of bromate. Remove chlorite in accordance with the procedure
specified in 9.4, if necessary.
NOTE Any substance that has a retention time coinciding with bromate and that produces a detector response can
interfere. A high concentration of ions can have an impact on the resolution and on the analyte’s retention time. Sample
dilution and/or gradient elution overcomes much interference.
4 Principle
The sample is pretreated in order to remove ozone, chlorine dioxide, chlorite, metals and solids, if necessary
(see Clause 8). Bromate is separated by ion chromatography (IC). An anion exchange resin is used as the
stationary phase and either acids (e.g. sulfuric acid) or aqueous solutions of salts of weak monobasic acids
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.