EN ISO 17871:2020/A2:2026
(Amendment)Gas cylinders - Quick-release cylinder valves - Specification and type testing - Amendment 2 (ISO 17871:2020/Amd 2:2026)
- Status
- Not Published
- Publication Date
- 01-Dec-2026
- Technical Committee
- CEN/TC 23 - Transportable gas cylinders
- Drafting Committee
- CEN/TC 23/WG 20 - Cylinder design - Fittings
- Current Stage
- 5060 - Closure of Vote - Formal Approval
- Start Date
- 26-Oct-2026
- Due Date
- 26-Oct-2026
- Completion Date
- 26-Oct-2026
EN ISO 17871:2020/A2:2026 is a CEN amendment to EN ISO 17871:2020 for gas cylinders with quick-release cylinder valves. It updates the specification and type-testing rules for valves used as closures, with changes to scope wording, referenced standards, leak-tightness tests, hydraulic pressure tests, and marking.
What does EN ISO 17871:2020/A2:2026 specify?
EN ISO 17871:2020/A2:2026 amends the base standard for quick-release cylinder valves by changing the text in Clause 1, Clause 2, Clause 4, Clause 5, and Annex A. The amendment keeps the focus on the valve’s closure function and aligns the document with newer companion standards.
Clause 1 is narrowed so that EN ISO 17871:2020/A2:2026 covers only the function of a quick-release cylinder valve as a closure. Other functions that may be built into the valve can be covered by other standards, but those other standards are not requirements of this document.
A note added to the scope points users to ISO 16003 for some fixed fire-fighting systems, to EN 12094-4 at regional level, and to ISO 15996 for residual pressure valves (RPV).
What are the key requirements of EN ISO 17871:2020/A2:2026?
EN ISO 17871:2020/A2:2026 keeps the base requirement that quick-release cylinder valves shall comply with the relevant requirements of ISO 10297, ISO 17879 or ISO 23826, except Clause 8, unless this document sets different or additional requirements. In practice, users need to check which companion standard applies to the valve design before testing or certification.
Main technical changes
- Filling connection non-return valve - Where the filling connection is separate from the outlet and fitted with a non-return valve, the valve has to meet the ISO 10297 requirement for that non-return valve, but the endurance-cycle count is set by the manufacturer. This lets the supplier define the cycle life while still meeting the referenced performance basis.
- External leakage limit - Where external leakage is tested, the total external leakage shall not exceed 12 cm3/h. This gives a clear leakage ceiling for type testing and makes the acceptance limit straightforward to verify.
- Valve hydraulic test pressure - For extinguishing agents charged with compressed gases, the valve hydraulic test pressure p_vht is calculated as 1.5 times p_vt. The amendment also uses p_vht consistently for hydraulic pressure testing terminology.
- Hydraulic pressure test evidence - The manufacturer has to show that the valve design can withstand p_vht throughout the valve body. This is a design-validation requirement, not just a spot check on one area.
- Leak-tightness test exemptions - Some internal and external leak-tightness tests are not required in defined cases, including type A valves, certain fixed fire-fighting systems in covered areas, and valves with specific operating arrangements. In practice, the test plan depends on the valve type and the intended service.
- Endurance and operating-condition testing - Certain tests are only required for valves designed for intermittent discharge or for valves whose operating mechanism is open in stand-by operation. This keeps testing tied to real service conditions.
- Marking - Valves conforming to the document shall be permanently and legibly marked before entering service by approved permanent methods, not by adhesive labels. The markings must be separated by at least one space, and extra marking may be required by regulations or customer requests.
What terms does EN ISO 17871:2020/A2:2026 define?
EN ISO 17871:2020/A2:2026 uses several terms that matter for testing and marking.
- Quick-release cylinder valve - A valve for a gas cylinder that is intended to open quickly; the amendment treats it as a closure device first and foremost.
- Closure - The sealing function of the valve that closes the cylinder; other integrated functions are outside the scope of this document’s requirements.
- Residual pressure valve (RPV) - A valve type with extra requirements referenced in the scope note to ISO 15996.
- Fixed fire-fighting systems - Installed fire-protection systems such as those in buildings, windmills, ships, and oil platforms; some leak-tightness tests are relaxed for these systems in defined conditions.
- Intermittent discharge - A service mode in which discharge is not continuous; certain leak-tightness tests apply only to valves designed for this mode.
- p_vht - The valve hydraulic pressure test pressure used for hydraulic strength verification of the valve body.
Who uses EN ISO 17871:2020/A2:2026?
EN ISO 17871:2020/A2:2026 is used by valve manufacturers, type-testing laboratories, certification bodies, and quality managers working with gas cylinders and cylinder valves. It is also relevant to designers and suppliers of fixed fire-fighting systems, especially where quick-release cylinder valves are part of the installation.
In practice, these users apply the document when selecting the right companion standard, defining the test programme, deciding which leak-tightness tests apply, setting hydraulic test pressure, and preparing permanent product markings.
What changed in EN ISO 17871:2020/A2:2026 from the previous edition?
EN ISO 17871:2020/A2:2026 amends EN ISO 17871:2020 by updating or replacing several clauses and references.
- It changes the scope wording so the document covers the closure function of the valve.
- It adds the scope note pointing to ISO 16003, EN 12094-4, and ISO 15996.
- It updates cross-references from ISO 10297:2014+Amd1:2017 to ISO 10297:2024 and from ISO 17879:2017 to ISO 17879:2026.
- It revises several test provisions, including leak-tightness exemptions, external leakage limits, and hydraulic pressure terminology.
- It changes marking wording and the list of acceptable permanent marking methods.
- It updates Annex A references from ISO 17879:2017 Annex D to ISO 17879:2026 Annex E.
Which standards are used with EN ISO 17871:2020/A2:2026?
EN ISO 17871:2020/A2:2026 works with several referenced standards that supply the detailed requirements it points to.
- ISO 10297:2024 - Provides the main companion requirements and test references for relevant quick-release cylinder valve features.
- ISO 17879:2026 - Provides another companion basis for applicable valve requirements and test references.
- ISO 23826:2021 - Supplies the alternative basis used where the valve falls under that document’s application.
- ISO 16003 - Gives additional requirements for quick-release cylinder valves used in fixed fire-fighting systems.
- EN 12094-4 - Gives regional requirements for certain fixed fire-fighting system applications.
- ISO 15996 - Gives additional requirements for residual pressure valves (RPV).
What does the EN ISO 17871:2020/A2:2026 document contain?
EN ISO 17871:2020/A2:2026 contains replacement text for the scope, normative references, performance and test requirements, marking rules, and Annex A cross-references. It also adds notes that guide users to related standards for fixed fire-fighting systems and residual pressure valves.
The amendment refers users to detailed test tables and test procedures in ISO 10297, ISO 17879, and ISO 23826, including leak-tightness and hydraulic pressure test conditions. It also adjusts the wording around what evidence the manufacturer has to provide for pressure resistance and which tests may be omitted for defined valve types and service conditions.
Relations
- Consolidated By
ISO 17871:2020/Amd 2:2026 - Gas cylinders — Quick-release cylinder valves — Specification and type testing — Amendment 2 - Effective Date
- 12-Feb-2026
- Effective Date
- 05-Jun-2024
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au
Sponsored listings
Frequently Asked Questions
EN ISO 17871:2020/A2:2026 is a draft published by the European Committee for Standardization (CEN). Its full title is "Gas cylinders - Quick-release cylinder valves - Specification and type testing - Amendment 2 (ISO 17871:2020/Amd 2:2026)". This standard covers: Gas cylinders - Quick-release cylinder valves - Specification and type testing - Amendment 2 (ISO 17871:2020/Amd 2:2026)
Gas cylinders - Quick-release cylinder valves - Specification and type testing - Amendment 2 (ISO 17871:2020/Amd 2:2026)
EN ISO 17871:2020/A2:2026 is classified under the following ICS (International Classification for Standards) categories: 23.020.35 - Gas cylinders; 23.060.40 - Pressure regulators. The ICS classification helps identify the subject area and facilitates finding related standards.
EN ISO 17871:2020/A2:2026 has the following relationships with other standards: It is inter standard links to ISO 17871:2020/Amd 2:2026, EN ISO 17871:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN ISO 17871:2020/A2:2026 is associated with the following European legislation: EU Directives/Regulations: 2008/68/EC; Standardization Mandates: M/TDG. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN ISO 17871:2020/A2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Foreword
- 4.1 First paragraph
- 4.1 Last paragraph
- 5 First paragraph
- 5 Indent g)
- 5 Indent i)
- 5 Last paragraph and Note
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISO's adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html. This document was prepared by Technical Committee ISO/TC 58, Gas cylinders, Subcommittee SC 2, Cylinder valves.
Any feedback or questions on this document should be directed to the user’s national standards body. A complete listing of these bodies can be found at www.iso.org/members.html.
SIST EN ISO 17871:2020/oprA2:2026
SIST EN ISO 17871:2020/oprA2:2026 ISO 17871:2020/DAM 2:2026(en) Gas cylinders — Quick-release cylinder valves — Specification and type testing AMENDMENT 2
1 Scope, paragraph after NOTE 2 Replace the paragraph with the following paragraph:
“This document only covers the function of a quick-release cylinder valve as a closure. Other functions that are possibly integrated in the valve can be covered by other standards. Such standards do however not constitute requirements according to this document.”
1 Scope, new NOTE 3 Add the following Note at the end of clause 3:
“NOTE 3 Certain specific requirements for quick-release cylinder valves for fixed fire-fighting systems in addition to those that are given in this document are specified in ISO 16003 and at a regional level, e.g. in EN 12094–4. Certain specific requirements for residual pressure valves (RPV), in addition to those that are given in this document, are given in ISO 15996.”
2 Reference to ISO 10297 and ISO 17879 Substitute “ISO 10297:2014+Amd1:2017” with “ISO 10297:2024” and “ISO 17879:2017” with “ISO 17879:2026”.
4.1 First paragraph
Substitute the first paragraph with the following paragraph:
“Quick-release cylinder valves shall comply with all requirements of ISO 10297, ISO 17879 or ISO 23826 (except Clause 8), as applicable, unless this document expressly allows differing requirements or stipulates additional requirements.”
4.1 Last paragraph
Substitute “ISO 10297:2014+Amd1:2017, 5.2” with “ISO 10297:2024, 5.2” and “ISO 17879:2017, 5.2” with “ISO 17879:2026, 5.2”.
4.2.1 First paragraph
Substitute the first paragraph with the following paragraph:
“Differing from the requirements given in ISO 23826:2021, 5.3, if the valve filling connection is separated from the valve outlet connection and equipped with a non-return valve, the requirements for the filling
...