Methodology for functional safety assessment of protective systems for potentially explosive atmospheres

This European Standard provides guidance on the procedure and information required to allow functional safety assessment to be carried out for the design of protective systems.
The purpose of this European Standard is to assist technical standardization committees responsible for specific families of protective systems in preparing safety standards. Such standards shall be as homogenous as possible and shall have the basic structure of functional safety assessment as it is stated in this standard.
If there are no specific standards for a particular protective system, the manufacturer shall use this standard for functional safety assessment of this protective system.
In this procedure the following information is to be taken into account to ensure a sufficient level of functional safety:
a)   intended use,
b)   possible operating faults,
c)   reliability of protective systems,
d)   misuse which can reasonably be anticipated.
A sufficient level of functional safety is characterized by the following objectives:
1)   System can stop an explosion at a very early stage or reduce the impact of an explosion to an acceptable level.
2)   In the event of faults, failures and/or interference ) the capacity to function remains effective by use e.g. of fail safe techniques or redundancy.
This European Standard does not cover identification of possible ignition sources.
NOTE 1   The identification of possible ignition sources is covered by EN 15198.
This European Standard only deals with the functional behaviour of the protective system i.e. hazards caused by malfunctions, e.g. false activations are excluded.
This European Standard specifies neither specific methods to analyse fault conditions, nor specific requirements for a given type of protective system (see EN 1127 1). It specifies the methodology of functional safety assessment.
(continued)

Methodik zur Bewertung der funktionalen Sicherheit von Schutzsystemen für explosionsgefährdete Bereiche

Méthodologie relative à l'évaluation de la sécurité fonctionnelle des systèmes de protection pour atmosphères explosibles

La présente norme européenne donne des lignes directrices relatives au mode opératoire et aux informations requises pour permettre la mise en oeuvre de l'évaluation de la sécurité fonctionnelle pour la conception des systèmes de protection.
La présente Norme européenne a pour objet d'aider les comités techniques de normalisation, responsables de familles spécifiques de systèmes de protection, à préparer les normes de sécurité. Il est recommandé que ces normes soient aussi homogènes que possible et qu’elles aient la structure de base indiquée dans la présente norme pour l’évaluation de la sécurité fonctionnelle.
En l’absence de normes spécifiques pour un système de protection donné, il est recommandé que le fabricant utilise cette norme pour l’évaluation de la sécurité fonctionnelle de ce système de protection.
Dans ce mode opératoire, les informations suivantes doivent être prises en compte pour assurer un niveau de sécurité fonctionnelle suffisant :
a)   l'utilisation prévue ;
b)   les défauts de fonctionnement possibles ;
c)   la fiabilité des systèmes de protection ;
d)   le mauvais usage pouvant être raisonnablement attendu.
Un niveau de sécurité fonctionnelle suffisant est caractérisé par les objectifs suivants :
1)   le système peut arrêter l'explosion dès son tout début ou réduire l'impact d'une explosion à un niveau acceptable ;
2)   en cas de défauts, de défaillances et/ou d'interférences  ) la capacité de fonctionner reste effective par l'utilisation, par exemple, de techniques de sécurité ou de redondance.
La présente Norme européenne ne traite pas de l'identification des sources d'inflammation possibles.

Metodologija za varnostno oceno delovanja zaščitnih sistemov za potencialno eksplozivne atmosfere

General Information

Status
Published
Publication Date
21-Aug-2007
Withdrawal Date
28-Feb-2008
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
06-Jul-2023

Buy Standard

Standard
EN 15233:2007
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Methodology for functional safety assessment of protective systems for potentially explosive atmospheresRWHQFLDOQRMéthodologie relative a l'évaluation de la sécurité fonctionnelle des systemes de protection pour atmospheres explosiblesMethodik zur Bewertung der funktionalen Sicherheit von Schutzsystemen für explosionsgefährdete BereicheTa slovenski standard je istoveten z:EN 15233:2007SIST EN 15233:2007en,fr,de13.230Varstvo pred eksplozijoExplosion protectionICS:SLOVENSKI
STANDARDSIST EN 15233:200701-oktober-2007







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15233August 2007ICS 13.230 English VersionMethodology for functional safety assessment of protectivesystems for potentially explosive atmospheresMéthodologie relative à l'évaluation de la sécuritéfonctionnelle des systèmes de protection pour atmosphèresexplosiblesMethodik zur Bewertung der funktionalen Sicherheit vonSchutzsystemen für explosionsgefährdete BereicheThis European Standard was approved by CEN on 13 July 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15233:2007: E



EN 15233:2007 (E) 2 Contents Page Foreword.3 Introduction.4 1 Scope.5 2 Normative references.6 3 Terms and definitions.6 4 General requirements.6 5 Functional safety assessment procedure.8 6 Documentation.13 Annex A (informative)
Example of a functional safety assessment.15 Annex B (informative)
Methods for failure identification and functional safety assessment.20 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 94/9/EC.23 Bibliography.24



EN 15233:2007 (E) 3 Foreword This document (EN 15233:2007) has been prepared by Technical Committee CEN/TC 305 “Potentially explosive atmospheres - Explosion prevention and protection”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2008, and conflicting national standards shall be withdrawn at the latest by February 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mand
...