Abstract

This document specifies methods by which the measurement of irradiance (fluence) distribution is made and specifies parameters for the characterization of the spatial properties of laser irradiance (fluence) distribution functions at a given plane.
The methods given in this document are intended to be used for the testing and characterization of both continuous wave (cw) and pulsed laser beams used in optics and optical instruments.
This document provides definitions of terms and symbols to be used in referring to irradiance distribution, as well as requirements for its measurement. For pulsed lasers, the distribution of time-integrated irradiance (i.e. radiant exposure) is the quantity most often measured.

Status
Published
Publication Date
21-Jul-2026
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
22-Jul-2026
Due Date
22-Jul-2026
Completion Date
22-Jul-2026

Buy Documents

Standard

EN ISO 13694:2026

English language (26 pages)
Preview
Preview
e-Library read for
×1 day

EN ISO 13694:2026 is a CEN European Standard that adopts ISO 13694:2026 without modification. It specifies methods for measuring laser beam irradiance (fluence) distribution and the parameters used to characterize the spatial properties of that distribution at a given plane, for both continuous wave (cw) and pulsed laser beams used in optics and optical instruments.

What does EN ISO 13694:2026 specify?

EN ISO 13694:2026 specifies how to measure laser beam irradiance (fluence) distribution and how to describe its spatial properties in a defined plane. It is written for testing and characterization work on cw and pulsed laser beams, and it also defines the terms and symbols used for those measurements.

The document is organized into clauses covering scope, normative references, terms and definitions, coordinate system, derived parameters, test principle, measurement arrangement, test procedure, evaluation, and test report. Annex A gives an informative test report form.

What are the key requirements of EN ISO 13694:2026?

EN ISO 13694:2026 centers on measuring the beam distribution first, then calculating the beam-shape parameters from that measured distribution. In practice, that means the test setup, detector calibration, and background correction all matter because they directly affect the reported beam size, shape, and uniformity.

Measurement basis and coordinate system

Clause 4 sets the X, Y, Z Cartesian coordinate system, with X and Y transverse to the beam and Z along the propagation direction. For elliptical beams, the principal axes should coincide with X and Y; if the beam is rotated, the azimuth angle provisions from ISO 11146-1 apply. This matters because the reported widths, diameters, and shape parameters depend on the chosen axes.

Clause 5 states that parameters such as beam centroid, beam width, beam diameter, flatness factor, and beam uniformity are calculated from the measured distribution after proper background subtraction. The clipping threshold should be set above detector background noise peaks. This keeps noise in the wings from dominating the results.

Test principle and applicable beam types

Clause 6 says the irradiance or fluence distribution is measured with a spatially resolving detector placed directly in the beam or through a suitable imaging system. The method requires a stationary distribution; for beams with temporal fluctuation, a mean irradiance or fluence is used. For pulsed lasers, the quantity of interest is usually the time-integrated irradiance, referred to here as fluence or radiant exposure.

Detector, optics, and environment requirements

Clause 7 requires a measurement device with high spatial resolution and high dynamic range. The detector system is expected to have a dynamic range greater than 100:1 and enough spatial sampling to register more than 2 500 non-overlapping data points. In practice, this is what lets users resolve fine structure in the beam instead of only a coarse average.

Clause 7.2 requires coaxial alignment of the beam and measuring system, with the optical system sized so that it accommodates the whole beam cross-section. Clipping or diffraction loss should be kept below 1 % of the total power or energy. This matters because any beam truncation can distort the measured profile.

Clause 7.3 calls for environmental control such as isolation, shielding from stray radiation, and temperature stabilization. Clause 7.4 also requires checking detector saturation, linearity, wavelength response, and damage thresholds, and it notes that pulsed-beam measurements must record trigger delay and sampling interval. Clause 7.5 requires optical attenuators, beam splitters, or relay optics to be suitable for the wavelength and not to alter the relative beam distribution significantly.

Calibration and background correction

Clause 8 requires equipment preparation before measuring, including a warm-up period of 1 h unless the manufacturer specifies otherwise. Spatial calibration is done with an obscuration of known size, and absolute radiant power or radiant pulse energy calibration is performed against an independent measurement, with ISO 11554 used for that step.

Clause 8.3 requires at least 10 independent measurements and reporting of the values and standard deviations. Background correction is mandatory before evaluating clipped or integrated parameters, and the standard provides two methods: subtraction of a full background map or subtraction of an average background level when the detector background is uniform. This is important because small offsets can create large errors in the calculated beam parameters.

Evaluation and consistency check

Clause 9 says the corrected distribution is used to calculate the parameters defined in Clause 3. For clip-level parameters, the clip level must be chosen above the maximum noise peaks of the corrected distribution. The standard also recommends checking self-consistency by uniformly attenuating the beam and confirming that the recalculated parameters stay within the required uncertainty.

What terms does EN ISO 13694:2026 define?

EN ISO 13694:2026 defines the beam quantities used to describe profile shape and size.

  • Irradiance distribution - the spatial distribution of radiant power density for a cw beam at a given plane.
  • Fluence distribution - the spatial distribution of radiant exposure for a pulsed beam at a given plane.
  • Beam centroid - the first-order moment location of the beam distribution, used as the profile center for calculations.
  • Beam width - the width derived from second-order moments about the centroid in the X and Y directions.
  • Encircled-power beam diameter - the diameter of a circular aperture that contains a stated fraction of the total beam power or pulse energy.
  • Clip-level beam width - the width of the region where irradiance or fluence is above a chosen fraction of the maximum.
  • Beam uniformity - the normalized rms deviation from the clip-level average value, used to quantify how even the profile is.

Who uses EN ISO 13694:2026?

EN ISO 13694:2026 is used by laboratories, manufacturers, and technical teams that measure and report laser beam profiles. It is relevant to engineers, quality managers, and buyers who need a defined test method for laser beam characterization in optics and optical instruments.

In practice, users apply it to set up beam-profile measurements, calibrate detectors, correct background signals, calculate beam-shape parameters, and prepare test reports that can be compared across systems or sites.

What changed in EN ISO 13694:2026 from the previous edition?

EN ISO 13694:2026 supersedes EN ISO 13694:2018, and ISO 13694:2026 is the fourth edition replacing ISO 13694:2018.

The main changes stated for this edition are:

  • The terms power, energy, power density, and energy density were replaced by radiant power, radiant energy, irradiance, and fluence to align with ISO 80000-7 and IEC Electropedia.
  • The terms beam width and beam diameter were restricted to the second-order-moment definitions from ISO 11146-1.
  • New terms were introduced for encircled-power beam width, encircled-power beam diameter, clip-level beam width, and clip-level beam diameter.

Which standards are used with EN ISO 13694:2026?

EN ISO 13694:2026 refers to these standards for terminology, related beam-width methods, and calibration:

  • ISO 11145 - provides the common vocabulary and symbols for laser and laser-related equipment.
  • ISO 11146-1 - provides the second-order-moment beam-width definitions and related beam-propagation terminology used here.
  • ISO/TR 11146-3 - gives details for variable aperture, scanning slit, and knife-edge methods, including the connection factor for the encircled-power beam diameter.
  • ISO 11554 - is used for the independent measurement of total beam radiant power or radiant pulse energy during absolute calibration.

What does the EN ISO 13694:2026 document contain?

EN ISO 13694:2026 contains equations for the measured quantities and derived beam parameters, along with the procedures used to calculate them from detector data. It includes guidance on coordinate systems, detector arrangement, calibration, environmental control, and background subtraction.

The document also contains a figure illustrating clip-level parameters for a uniform irradiance distribution in one dimension. Annex A gives an informative test report template covering laser details, test location, detection system, optical arrangement, reported beam parameters, and distribution data.

Relations

Effective Date
25-Sep-2024
Effective Date
12-Feb-2026

Buy Documents

Standard

EN ISO 13694:2026

English language (26 pages)
Preview
Preview
e-Library read for
×1 day

Frequently Asked Questions

EN ISO 13694:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Optics and photonics - Lasers and laser-related equipment - Test methods for laser beam irradiance (fluence) distribution (ISO 13694:2026)". This standard covers: This document specifies methods by which the measurement of irradiance (fluence) distribution is made and specifies parameters for the characterization of the spatial properties of laser irradiance (fluence) distribution functions at a given plane. The methods given in this document are intended to be used for the testing and characterization of both continuous wave (cw) and pulsed laser beams used in optics and optical instruments. This document provides definitions of terms and symbols to be used in referring to irradiance distribution, as well as requirements for its measurement. For pulsed lasers, the distribution of time-integrated irradiance (i.e. radiant exposure) is the quantity most often measured.

This document specifies methods by which the measurement of irradiance (fluence) distribution is made and specifies parameters for the characterization of the spatial properties of laser irradiance (fluence) distribution functions at a given plane. The methods given in this document are intended to be used for the testing and characterization of both continuous wave (cw) and pulsed laser beams used in optics and optical instruments. This document provides definitions of terms and symbols to be used in referring to irradiance distribution, as well as requirements for its measurement. For pulsed lasers, the distribution of time-integrated irradiance (i.e. radiant exposure) is the quantity most often measured.

EN ISO 13694:2026 is classified under the following ICS (International Classification for Standards) categories: 31.260 - Optoelectronics. Laser equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

EN ISO 13694:2026 has the following relationships with other standards: It is inter standard links to EN ISO 13694:2018, ISO 13694:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN ISO 13694:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 Measured quantities
  • 3.1.1 irradiance distribution
  • 3.1.1.1 irradiance
  • 3.1.2 fluence distribution
  • 3.1.2.1 fluence
  • 3.1.3 radiant power
  • 3.1.4 radiant pulse energy
  • 3.1.5 maximum irradiance
  • 3.1.6 maximum fluence
  • 3.1.7 location of the maximum
  • 3.1.8 clip-level irradiance
  • 3.1.9 clip-level fluence
  • 3.2 Characterizing parameters
  • 3.2.1 clip-level radiant power
  • 3.2.2 clip-level radiant energy
  • 3.2.3 fractional radiant power
  • 3.2.4 fractional radiant energy
  • 3.2.5 beam centroid
  • 3.2.6 beam width
  • 3.2.7 beam diameter
  • 3.2.8 encircled-power beam width
  • 3.2.9 encircled-power beam diameter
  • 3.2.10 clip-level beam width
  • 3.2.11 clip-level beam diameter
  • 3.2.12 beam ellipticity
  • 3.2.13 beam cross-sectional area
  • 3.2.14 clip-level irradiation area
  • 3.2.15 clip-level average irradiance
  • 3.2.16 clip-level average fluence
  • 3.2.17 flatness factor
  • 3.2.18 beam uniformity
  • 3.2.19 plateau uniformity
  • 3.2.20 edge steepness
  • 4 Coordinate system
  • 5 Characterizing parameters derived from the measured spatial distribution
  • 6 Test principle
  • 7 Measurement arrangement and test equipment
  • 7.1 General
  • 7.2 Preparation
  • 7.3 Control of environment
  • 7.4 Detector system
  • 7.5 Beam-forming optics, optical attenuators, and beam splitters
  • 8 Test procedure
  • 8.1 Equipment preparation
  • 8.2 Detector calibration procedure
  • 8.3 Data recording and noise correction
  • 9 Evaluation
  • 10 Test report
  • Annex A
  • Bibliography

Introduction

Many applications of lasers involve using the near-field as well as the far-field irradiance (fluence) distribution of the beam. The irradiance (fluence) distribution of a laser beam is characterized by the spatial distribution of radiant power density (radiant energy fluence) with lateral displacement in a particular plane perpendicular to the direction of propagation. In general, the irradiance (fluence) distribution of the beam changes along the direction of propagation. Depending on the radiant power (energy), size, wavelength, polarization, and coherence of the beam, different methods of measurement are applicable in different situations. Five methods are commonly used: camera arrays (1D and 2D), apertures, pinholes, slits, and knife edges.

According to ISO 11145, it is possible to use two different definitions for describing and measuring the laser beam diameter. One definition is based on the measurement of the encircled radiant power (energy); the other is based on determining the spatial moments of the irradiance (fluence) distribution of the laser beam. The use of spatial moments is necessary for calculating the beam propagation factor, K, and the beam

propagation ratio, M , from measurements of the beam widths at different distances along the propagation axis. ISO 11146-1 and ISO 11146-2 describe this measurement procedure. For other applications, other definitions for the beam diameter can be used. For some quantities used in this document the beam width based on the encircled radiant power (energy) is more appropriate and easier to use.

SIST EN ISO 13694:2026

SIST EN ISO 13694:2026 International Standard ISO 13694:2026(en) Optics and photonics — Lasers and laser-related equipment - Test methods for laser beam irradiance (fluence) distribution

1 Scope

This document specifies methods by which the measurement of irradiance (fluence) distribution is made and specifies parameters for the characterization of the spatial properties of laser irradiance (fluence) distribution functions at a given plane.

The methods given in this document are intended to be used for the testing and characterization of both continuous wave (cw) and pulsed laser beams used in optics and optical instruments. This document provides definitions of terms and symbols to be used in referring to irradiance distribution, as well as requirements for its measurement. For pulsed lasers, the distribution of time-integrated irradiance (i.e. radiant exposure) is the quantity most often measured.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 11145, Optics and photonics — Laser and laser-related equipment — Vocabulary and symbols ISO 11146-1, Lasers and laser-related equipment — Test methods for laser beam widths, divergence angles and beam propagation ratios — Part 1: Stigmatic and simple astigmatic beams ISO/TR 11146-3, Lasers and laser-related equipment — Test methods for laser beam widths, divergence angles and beam propagation ratios — Part 3: Intrinsic and geometrical laser beam classification, propagation and details of test methods

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 11145 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 Measured quantities

3.1.1 irradiance distribution

E(x, y, z) set of all radiant power densities at location z of a certain cw beam with non-negative values for all transverse coordinates (x, y) Note 1 to entry: E(x, y, z) is represented as a density of incident radiant power P(z) with respect to area A at a location (x, y).

SIST EN ISO 13694:2026 ISO 13694:2026(en) dPz() Ex(, yz,)= dA [SOURCE: ISO 80000-7:2019, 7-7.1, modified — Radiant flux symbol, Φ , has been replaced by P(z).] e

3.1.1.1 irradiance

E(x , y , z) P P portion of the beam radiant power at location z which impinges on the area, δA, at the location (x , y ) divided P P by the area δA in the limit δA → 0 [SOURCE: ISO 11145:2026, 3.13.6, modified — Notes to entry have been omitted.]

3.1.2 fluence distribution

H(x, y, z) set of all radiant exposure at location z of a certain pulsed beam with non-negative values for all transverse coordinates (x, y) Hx(, yz,) Ex(, yz,)dt

3.1.2.1 fluence

H(x , y , z) P P <pulsed laser beam> portion of the beam radiant energy (time-integrated radiant power) at location z which impinges on the area, δA, at the location (x , y ) divided by the area δA in the limit δA → 0 P P Hx(, yz,) Ex(, yz,)dt PP  PP [SOURCE: ISO 11145:2026, 3.13.4, modified — Notes to entry have been omitted.] Note 1 to entry: The terminology “fluence” described in this document is equivalent to “radiant exposure” (refer to ISO 80000-7).

3.1.3 radiant power

P(z) rate of radiant energy transfer in a continuous wave (cw) beam at location z Pz() Ex(, yz,)ddxy

3.1.4 radiant pulse energy

Q(z) radiant energy in one pulse measured at location z Qz() Hx(, yz,)ddxy

[SOURCE: ISO 11145:2026, 3.13.3, modified — "Measured at location z", formula Q(z) and “radiant” have been included in the term.]

3.1.5 maximum irradiance

E (z) max maximum of the spatial irradiance distribution (3.1.1) function E(x, y, z) at location z

SIST EN ISO 13694:2026 ISO 13694:2026(en)

3.1.6 maximum fluence

H (z) max maximum of the spatial fluence distribution (3.1.2) function H(x, y, z) at location z

3.1.7 location of the maximum

(x , y , z) max max location of E (z) or H (z) in the xy plane at location z max max Note 1 to entry: (x , y , z) cannot be uniquely defined when measuring with detectors having a high spatial max max resolution and a relatively small dynamic range.

3.1.8 clip-level irradiance

E (z) ηCL fraction η of the maximum irradiance (3.1.5) at location z Ez()Ez() CL max 0 ≤ η < 1 Note 1 to entry: When no confusion is possible, the explicit dependence on z is dropped in the text description using some quantities, but not in the definitions or in the Formulae involving the quantities.

3.1.9 clip-level fluence

H (z) ηCL fraction η of the maximum fluence (3.1.6) at location z Hz()Hz() CL max 0 ≤ η < 1 Note 1 to entry: When no confusion is possible, the explicit dependence on z is dropped in the text description using some quantities, but not in the definitions or in the Formulae involving the quantities.

3.2 Characterizing parameters

3.2.1 clip-level radiant power

P (z) η integral of the radiant power (3.1.3) distribution at location z, evaluated by summing only over locations (x,y) for which E(x, y, z) > E (z) ηCL

3.2.2 clip-level radiant energy

Q (z) η integral of the radiant pulse energy (3.1.4) distribution at location z, evaluated by summing only over locations (x,y) for which H(x, y, z) > H (z) ηCL

SIST EN ISO 13694:2026 ISO 13694:2026(en)

3.2.3 fractional radiant power

f (z) η fraction of the clip-level radiant power (3.2.1) for a given η to the total radiant power (3.1.3) in the distribution at location z Pz()

fz()

Pz() 0 ≤ f (z) ≤ 1 η

3.2.4 fractional radiant energy

g (z) η fraction of the clip-level radiant energy (3.2.2) for a given η to the total radiant pulse energy (3.1.4) in the distribution at location z Qz()

gz()

Qz() 0 ≤ g (z) ≤ 1 η

3.2.5 beam centroid

xz(),(yz)

coordinates of the first-order moments of a radiant power (3.1.3) distribution or a radiant pulse energy (3.1.4) distribution of a beam at location z xE(,xy,)zxddy

xz() Ex(, yz,)ddxy

yE(,xy,)zxddy

yz() Ex(, yz,)ddxy

where the integration shall be performed over an area such that at least 99 % of the beam radiant power (3.1.3) or radiant pulse energy (3.1.4) is captured Note 1 to entry: The irradiance (3.1.1.1) E is replaced by the fluence (3.1.2.1) H for pulsed lasers. Note 2 to entry: For a more detailed definition, see ISO 11145 and ISO 11146-1.

3.2.6 beam width

d (z), d (z) σx σy widths d (z) and d (z) of the beam in the respective x and y directions at z, equal to four times the square σx σy 2 2 root of the second order moments σ ()z and σ ()z of the irradiance distribution (3.1.1) or fluence x y distribution (3.1.2) about the centroid dz() 4 ()z xx dz() 4 ()z  yy

SIST EN ISO 13694:2026 ISO 13694:2026(en)

xzx() Ex(, yz,) ddxy

2    ()z 

Ex(, yz,)ddxy

yy ()zE (,xy,)zxddy

2    ()z  y

Ex(, yz,)ddxy

Note 1 to entry: Refer to ISO 11145 and ISO 11146-1.

3.2.7 beam diameter

d (z) σ diameter defined by using the second order moment σ()z of the irradiance distribution (3.1.1) function or fluence distribution (3.1.2) function dz() 22()z

xx ()zy  yz() Ex(, yz,)ddxy

 ()z 

Ex(, yz,)ddxy

3.2.8 encircled-power beam width

d (z), d (z) x,u y,u widths d (z) and d (z) of the smallest slit aligned with the principal axis X or Y of the irradiance distribution x,u y,u (3.1.1) function or fluence distribution (3.1.2) function, transmitting u % of the total beam radiant power (3.1.3) or radiant pulse energy (3.1.4) along X or Y Note 1 to entry: The encircled-power beam widths d (z) and d (z) can be measured by the moving knife-edge x,u y,u method (refer to ISO/TR 11146-3).

3.2.9 encircled-power beam diameter

d (z) u diameter of the smallest circular aperture in a plane perpendicular to the beam axis that contains u % of the total beam radiant power (3.1.3) or radiant pulse energy (3.1.4) Note 1 to entry: For u=86,5, d (z) corresponds to the uncorrected beam diameter measured by the variable aperture u method (see ISO/TR 11146-3). The connection factor relating d and d is given in ISO/TR 11146-3. 86,5 σ

3.2.10 clip-level beam width

CL CL dz(),(dz) xy,,ηη CL CL widths dz() and dz() of the slit area aligned with the principal axis x or y of the irradiance distribution x,η y,η (3.1.1) function or fluence distribution (3.1.2) function, wherein irradiance (3.1.1.1) E(x, y, z) > E (z) or ηCL fluence (3.1.2.1) H(x, y, z) > H (z) ηCL Note 1 to entry: If η=0.5, then the clip-level beam width is so-called FWHM (full width at half maximum).

SIST EN ISO 13694:2026 ISO 13694:2026(en) CL CL Note 2 to entry: For ideal Gaussian beam (TEM ), dz()dz() , and dz()dz() .

x  y 2 2 x,/1 e y,/1 e Note 3 to entry: The position where the clip-level beam width is minimum does not necessarily coincide with the beam waist position.

3.2.11 clip-level beam diameter

CL dz() η diameter of a circular aperture in a plane perpendicular to the beam axis wherein irradiance (3.1.1.1) E(x, y, z) > E (z) or fluence (3.1.2.1) H(x, y, z) > H (z) ηCL ηCL CL Note 1 to entry: For ideal Gaussian beam (TEM ), dz()dz() .

1/e Note 2 to entry: The position where the clip-level beam diameter is minimum does not necessarily coincide with the beam waist position.

3.2.12 beam ellipticity

ε(z) parameter for quantifying the circularity or squareness of a radiant power (3.1.3) distribution or a radiant pulse energy (3.1.4) distribution at an axial location z

min(dz),dz() xy''

()z 

max(dz),dz() xy''

Note 1 to entry: It follows that 0<ε(z)≤1.

Note 2 to entry: If ε ≥ 0,87, elliptical distributions can be regarded as circular. Note 3 to entry: In case of a rectangular distribution, beam ellipticity is often referred to as aspect ratio. Note 4 to entry: In contrast to the definition given here, in literature the term beam ellipticity is sometimes related to dz()  y 1 . The definition given here has been chosen to be in concordance with the same definition of beam dz() x ellipticity in ISO 11146-1 and ISO 11145.

[SOURCE: ISO 11146-1:2021, 3.6, modified — In Note 4 to entry ISO 13694 has been changed to ISO 11145.]

3.2.13 beam cross-sectional area

A (z) σ <second order moment of irradiance distribution (3.1.1) function or fluence distribution (3.1.2) function > area of a beam with circular cross-section

Ad  ()z

or elliptical cross-section

Ad ()zd ()z

xy

Note 1 to entry: For clarity, the term “beam cross-sectional area” is always used in combination with the symbol and its appropriate subscript: A or A .

u σ [SOURCE: ISO 11145:2026, 3.6.2]

SIST EN ISO 13694:2026 ISO 13694:2026(en)

3.2.14 clip-level irradiation area

Az() η irradiation area at location z for which the irradiance (3.1.1.1) E(x, y, z) > E (z) or fluence (3.1.2.1) H(x, y, z) ηCL > H (z) ηCL Note 1 to entry: To allow for distributions of all forms, for example hollow “donut” types, the clip-level irradiation area is not defined in terms of the beam widths (3.2.6) d or d .

σx σy Note 2 to entry: See clip-level irradiance (3.1.8) and clip level fluence (3.1.9).

3.2.15 clip-level average irradiance

E (z) ηave spatially averaged irradiance (3.1.1.1) of the distribution at location z, defined as the weighted mean Pz()

Ez() ave

Az()

Note 1 to entry: E (z) and E (z) (see 3.1.8) refer to different parameters. ηave ηCL

3.2.16 clip-level average fluence

H (z) ηave spatially averaged fluence (3.1.2.1) of the distribution at location z, defined as the weighted mean Qz()

Hz() ave

Az()

Note 1 to entry: H (z) and H (z) (see 3.1.9) refer to different parameters. ηave ηCL

...