EN 1401-1:2019/prA1
(Amendment)Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC U) piping systems in the field of non-pressure underground drainage and sewerage:
- buried in ground outside the building structure (application area code "U"), and
- both buried in ground, within the building structure and outside the building (application area code "UD").
NOTE 1 The intended use is reflected in the marking of products by "U" or "UD".
It also specifies the test parameters for the test methods referred to in this document.
NOTE 2 Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 13476-2 [1].
This document covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours.
NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
It is applicable to PVC U pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 16.
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre, Formstücke und das Rohrleitungssystem
Systèmes de canalisations en plastique pour les branchements et les collecteurs d'assainissement enterrés sans pression - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1 : Spécifications pour tubes, raccords et le système
Cevni sistemi iz polimernih materialov za odpadno vodo in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Nemehčan polivinilklorid (PVC-U) - 1. del: Specifikacije za cevi, fitinge in sistem - Dopolnilo A1
General Information
- Status
- Not Published
- Publication Date
- 21-May-2023
- Technical Committee
- CEN/TC 155 - Plastics piping systems and ducting systems
- Current Stage
- 4097 - End of interruption of work - split/merged
- Start Date
- 12-Jan-2023
- Completion Date
- 14-Apr-2025
Relations
- Effective Date
- 18-Jan-2023
- Effective Date
- 13-Oct-2021
Overview
EN 1401-1:2019/prA1 - titled "Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC‑U) - Part 1: Specifications for pipes, fittings and the system" (CEN) specifies requirements for solid-wall PVC‑U pipes, fittings and system components used in non‑pressure underground drainage and sewerage. It covers pipes with smooth internal/external surfaces, fittings, joints and test parameters for buried applications designated by application area codes "U" (outside building) and "UD" (inside and outside building). Products are marked “U” or “UD” to identify intended use.
Key topics and technical requirements
- Material and formulation
- Minimum PVC content: ≥ 80% by mass for extruded pipes; ≥ 85% for injection‑moulded fittings.
- Density range: 1 350 kg/m3 ≤ density ≤ 1 600 kg/m3.
- PVC content may be measured via chlorine content (EN ISO 1158) or by ash‑rest (EN ISO 3451‑5, Method A) when reprocessed/recycled material is used.
- Physical properties and testing
- Specifies test parameters and references international test methods (amendment A1 updates normative references to EN ISO 1158 and EN ISO 6259‑2).
- Defines stiffness classes, nominal sizes and acceptable series of pipes/fittings.
- Joints and compatibility
- Requirements for joint dimensions (see Clause 7) and joint performance (see Table 16).
- Compatibility note: components conforming to plastics standards in Annex C may be used if joint dimensions and Table 16 requirements are met.
- Scope limitations
- Multilayer or foamed-core pipes are excluded (covered by EN 13476‑2).
- Purchaser responsibility
- Specifier must select appropriate nominal size, series, stiffness class and color per local regulations and installation practices.
Applications and who uses this standard
- Typical applications: gravity drainage, stormwater sewers, external and internal buried sewer runs where non‑pressure flow is required.
- Primary users:
- Manufacturers of PVC‑U pipes, fittings and joint systems
- Design engineers and specifiers for civil and infrastructure projects
- Contractors / installers responsible for underground drainage systems
- Testing laboratories and conformity assessors
- Procurement officers and regulators ensuring compliance with CEN requirements
Related standards
- EN 1401‑1:2019 (base standard) and this draft amendment A1
- EN ISO 1158 (chlorine content / PVC measurement)
- EN ISO 6259‑2 (tensile properties for PVC pipes)
- EN ISO 3451‑5 (ash‑rest method)
- EN 13476‑2 (multilayer/structured-wall systems)
- Annex C (compatible plastics product standards)
Keywords: EN 1401‑1:2019/prA1, PVC‑U, non‑pressure underground drainage, sewerage, pipes and fittings, joints, CEN, EN ISO 1158, EN ISO 6259‑2.
Frequently Asked Questions
EN 1401-1:2019/prA1 is a draft published by the European Committee for Standardization (CEN). Its full title is "Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system". This standard covers: This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC U) piping systems in the field of non-pressure underground drainage and sewerage: - buried in ground outside the building structure (application area code "U"), and - both buried in ground, within the building structure and outside the building (application area code "UD"). NOTE 1 The intended use is reflected in the marking of products by "U" or "UD". It also specifies the test parameters for the test methods referred to in this document. NOTE 2 Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 13476-2 [1]. This document covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It is applicable to PVC U pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 16.
This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC U) piping systems in the field of non-pressure underground drainage and sewerage: - buried in ground outside the building structure (application area code "U"), and - both buried in ground, within the building structure and outside the building (application area code "UD"). NOTE 1 The intended use is reflected in the marking of products by "U" or "UD". It also specifies the test parameters for the test methods referred to in this document. NOTE 2 Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 13476-2 [1]. This document covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It is applicable to PVC U pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 16.
EN 1401-1:2019/prA1 is classified under the following ICS (International Classification for Standards) categories: 23.040.01 - Pipeline components and pipelines in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 1401-1:2019/prA1 has the following relationships with other standards: It is inter standard links to EN 1401-1:2019+A1:2023, EN 1401-1:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase EN 1401-1:2019/prA1 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2022
Cevni sistemi iz polimernih materialov za odpadno vodo in kanalizacijo, ki delujejo
po težnostnem principu in so položeni v zemljo - Nemehčan polivinilklorid (PVC-U)
- 1. del: Specifikacije za cevi, fitinge in sistem - Dopolnilo A1
Plastics piping systems for non-pressure underground drainage and sewerage -
Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and
the system
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -
leitungen - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an
Rohre, Formstücke und das Rohrleitungssystem
Systèmes de canalisations en plastique pour les branchements et les collecteurs
d'assainissement enterrés sans pression - Poly(chlorure de vinyle) non plastifié (PVC-U)
- Partie 1 : Spécifications pour tubes, raccords et le système
Ta slovenski standard je istoveten z: EN 1401-1:2019/prA1
ICS:
23.040.05 Cevovodi za zunanje Pipeline and its parts for
sisteme za odpadno vodo in external sewage systems
njihovi deli
91.140.80 Drenažni sistemi Drainage systems
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
EN 1401-1:2019
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
June 2022
ICS 23.040.01
English Version
Plastics piping systems for non-pressure underground
drainage and sewerage - Unplasticized poly(vinyl chloride)
(PVC-U) - Part 1: Specifications for pipes, fittings and the
system
Systèmes de canalisations en plastique pour les Kunststoff-Rohrleitungssysteme für erdverlegte
branchements et les collecteurs d'assainissement drucklose Abwasserkanäle und -leitungen -
enterrés sans pression - Poly(chlorure de vinyle) non Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1:
plastifié (PVC-U) - Partie 1 : Spécifications pour tubes, Anforderungen an Rohre, Formstücke und das
raccords et le système Rohrleitungssystem
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 155.
This draft amendment A1, if approved, will modify the European Standard EN 1401-1:2019. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...