This document gives guidance for specifying requirements for the AoC of compounds/formulations, products, joints and assemblies in accordance with the applicable part of EN 1566 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE   A basic test matrix provides an overview of the testing scheme in Annex A.
In conjunction with EN 1566 1 (see European foreword), this document is applicable to solid-wall piping systems made of chlorinated poly(vinyl chloride) (PVC C) intended to be used for or soil and waste discharge systems (low and high temperature):
-   inside buildings (application area code "B");
-   for both inside buildings and buried in ground within the building structure (application area code "BD").

  • Technical specification
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance for specifying requirements for the AoC of compounds/formulation, products, joints and assemblies in accordance with the applicable part of EN 1455 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE   A basic test matrix provides an overview of the testing scheme in Annex A.
In conjunction with EN 1455-1 (see European foreword), this document is applicable to solid wall piping systems made of acrylonitrile-butadiene-styrene (ABS) intended to be used for soil and waste discharge (low and high temperature):
-   inside buildings (application area code "B");
-   both inside buildings and buried in ground within the building structure (application area code "BD").

  • Technical specification
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid-wall pipes and fittings with or without internal and/or external skin, and the system of piping systems made from mineral modified polypropylene materials (PP-MD) in the field of non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and non-pressure underground drainage and sewerage for both buried in ground within the building structure and outside the building structure (application area code "UD").
This is reflected in the marking of products by "U" and "UD".
NOTE 1   The skins are made of PP compound without mineral modifier.
It also specifies the test parameters for the test methods referred to in this document.
This document covers a range of nominal sizes, a range of pipe stiffness classes and gives recommendations concerning colours.
NOTE 2   It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with Part 2 of EN 14758 (see European foreword) it is applicable to PP-MD pipes and fittings, their elastomeric sealing ring joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
This document is applicable to PP-MD pipes with or without an integral socket and fittings with an integral socket.
NOTE 3   The fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.
NOTE 4   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittings conforming to this document, when they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 11.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of chlorinated poly(vinyl chloride) (PVC-C) piping systems intended for soil and waste discharge (low and high temperature):
- inside buildings (application area code “B”);
- for both inside buildings and buried in ground within the building structure (application area code “BD”).
NOTE 1 The intended use is reflected in the marking of products by “B” or “BD”.
NOTE 2 Application “B” covers uses above ground inside buildings, or outside buildings fixed onto the wall.
NOTE 3 Pipes and fittings of the pipe series S 25 are intended to be used for application area “B” only.
NOTE 4 For use buried in ground within the building structure are intended only those components (marked with “BD”) with nominal outside diameters equal to or greater than 75 mm.
NOTE 5 EN 476 [5] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this document fully meet these requirements.
This document is applicable to PVC-C pipes and fittings and the system intended for the following purposes:
- ventilating part of the pipework in association with discharge applications;
- rainwater pipework within the building structure.
It also specifies the test parameters for the test methods that are referred to.
This document covers a range of nominal sizes, a range of pipe series and gives recommendations concerning colours.
NOTE 6 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 7 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex A can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 21.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of acrylonitrile-butadiene-styrene (ABS) and acrylonitrile-styrene-acrylester (ASA) piping systems intended for soil and waste discharge applications (low and high temperature):
- inside buildings (application area code “B”);
- for both inside buildings and buried in ground within the building structure (application area code “BD”).
NOTE 1 The intended use is reflected in the marking of products by “B” or “BD”.
NOTE 2 Application “B” covers uses above ground inside buildings, or outside buildings fixed onto the wall.
NOTE 3 Pipes and fittings of the pipe series S 25 are intended to be used for application area “B” only.
NOTE 4 For use buried in ground within the building structure are intended only those components (marked with “BD”) with nominal outside diameters equal to or greater than 75 mm.
NOTE 5 EN 476 [5] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this document fully meet these requirements.
This document is also applicable to ABS and ASA pipes, fittings and the system intended for the following purposes:
- ventilating part of the pipework in association with discharge applications;
- rainwater pipework within the building structure.
It also specifies the test parameters for the test methods that are referred to.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
NOTE 6 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 7 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex A can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 21.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems intended for soil and waste discharge applications (low and high temperature):
- inside buildings (application area code "B");
- for both inside buildings and buried in ground within the building structure (application area code "BD").
NOTE 1 The intended use is reflected in the marking of products by "B" or "BD".
NOTE 2 Application "B" covers uses above ground inside the building, or outside buildings fixed onto the wall.
NOTE 3 Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 1453-1 [1].
NOTE 4 For use buried in ground within the building structure are intended only those components (marked with "BD") with nominal outside diameters equal to or greater than 75 mm.
NOTE 5 EN 476 [2] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this standard fully meet these requirements.
This document is also applicable to PVC-U pipes, fittings and the system intended for the following purposes:
- ventilating part of the pipework in association with discharge applications;
- rainwater pipework within the building structure.
This document also specifies the test parameters for the test methods that are referred to.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
NOTE 6 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 7 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 26.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of formulations, products and assemblies in accordance with EN 1329-1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third party certification is involved, the certification body is expected to be compliant with either EN ISO/IEC 17065 [2] or EN ISO/IEC 17021-series [3], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1329-1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended for soil and waste discharge systems (low and high temperature):
-   inside buildings (application area code "B");
-   both inside buildings and buried in ground within the building structure (application area code "BD").

  • Technical specification
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with EN 1519 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If certification is involved, it is recommended that the certification body is compliant with either EN ISO/IEC 17065 [2] or EN ISO/IEC 17021-series [4], as applicable.
NOTE 3   A basic test matrix providing an overview of the testing scheme is given in Annex A.
In conjunction with EN 1519-1 this document is applicable to piping systems made of polyethylene (PE) intended to be used:
-   for soil and waste discharge systems (low and high temperature) inside buildings (application area code "B") and
-   for soil and waste discharge systems (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD").
This is reflected in the marking of products by "B" or "BD".

  • Technical specification
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of formulations, products and assemblies in accordance with EN 1401 1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third party certification is involved, the certification body is expected be compliant with either EN ISO/IEC 17065 [2] or EN ISO/IEC 17021-series [3], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1401 1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended for non-pressure underground drainage and sewerage:
-   buried in ground outside the building structure (application area code “U”);
-   both buried in ground within the building structure  and outside the building structure (application area code "UD").

  • Technical specification
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 1451 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third-party certification is involved, the certification body is expected be accredited to EN ISO/IEC 17065 [2] or EN ISO/IEC 17021 [3], as applicable.
NOTE 3   In order to help the readers, a summary of the test regime is given in Annex A.
In conjunction with EN 1451 1 this document is applicable to piping systems made of polypropylene (PP) intended to be used:
-   for soil and waste discharge systems (low and high temperature) inside buildings (application area code “B”) and,
-   for soil and waste discharge systems (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code “BD”)
This is reflected in the marking of products by “B” or “BD”.

  • Technical specification
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 1852 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   The quality management system is expected to conform to or be no less stringent than the relevant requirements in EN ISO 9001 [1].
NOTE 2   If third-party certification is involved, the certification body is expected be accredited to EN ISO/IEC 17065 [2] or EN ISO/IEC 17021 [3], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1852-1 this document is applicable to solid wall piping systems made of polypropylene (PP) intended to be used for:
-    non-pressure underground drainage and sewerage outside the building structure (application area code “U”), and
-   non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code “D”) and outside the building structure.
This is reflected in the marking of products by “U” and “UD”.

  • Technical specification
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid-wall polyethylene (PE) pipes with smooth internal and external surfaces extruded from the same compound/formulation throughout the wall, fittings and the system for:
-   soil and waste discharge applications (low and high temperature) inside buildings (application area code "B");
-   soil and waste discharge applications (low and high temperature) for both inside buildings and buried in the ground within the building structure (application area code "BD").
NOTE 1   The intended use is reflected in the marking of products by "B" or "BD".
NOTE 2   For use buried in the ground within the building structure are intended only those components marked with "BD", with a nominal ring stiffness of at least SN4 for dimensions equal to or greater than 75 mm.
This document is also applicable to PE pipes and fittings and the system intended for the following purposes:
-   ventilating part of the pipework in association with discharge applications;
-   rainwater pipework within the building structure.
It also specifies the test parameters for the test methods referred to in this standard.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
NOTE 3   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes, e.g. CEN/TR 13801 [1].
NOTE 4   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, if applicable.
It applies to pipes and fittings, marked with “B”, which are intended to be used inside buildings and outside buildings fixed onto the wall.
It applies to pipes and fittings, marked with “BD”, which are intended to be used for both inside buildings and buried in the ground within the building structure.
This standard is applicable to PE pipes and fittings of the following types:
-   plain-ended;
-   with integral elastomeric ring seal socket;
-   for butt fusion joints;
-   for electrofusion joints;
-   for mechanical joints
where the fittings can be manufactured by injection-moulding or can be fabricated from pipes and/or mouldings.
NOTE 5   EN 476[2] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this standard fully meet these requirements.
NOTE 6   For information about the chemical resistance of PE, guidance is given in ISO/TR 10358[3] and for rubber materials in ISO/TR 7620[4].

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 1451 specifies the requirements for solid-wall polypropylene (PP) pipes, fittings and the system intended for:
-   soil and waste discharge applications (low and high temperature) inside buildings (application area code "B");
-   soil and waste discharge applications (low and high temperature) for both inside buildings and buried in the ground within the building structure (application area code "BD").
This part of EN 1451 is also applicable to PP pipes and fittings and the system intended for the following purposes:
-   ventilating part of the pipework in association with discharge applications;
-   rainwater pipework within the building structure.
It also specifies the test parameters for the test methods referred to in this standard.
This standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
It applies to pipes and fittings, marked with "B", which are intended to be used inside buildings and outside buildings fixed onto the wall.
This standard is applicable to PP pipes and fittings of the following types:
-   plain-ended;
-   with integral elastomeric ring seal socket;
-   for butt fusion joints.
whereby the fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 1453 specifies the requirements for structured-wall unplasticized poly(vinyl chloride) (PVC U) pipes and the system intended to be used for soil and waste discharge applications (low and high temperature) inside buildings (application area code "B")
NOTE 1   The intended use is reflected in the marking of products by "B".
This part of EN 1453 is also applicable to structured-wall unplasticized poly(vinyl chloride) (PVC U) pipes, and the system intended for the following purposes:
   ventilating part of the pipework in association with discharge applications;
   rainwater pipework inside building.
It also specifies the test parameters for the test methods referred to in this standard.
NOTE 2   Single layer  foamed PVC U pipes and spirally-formed PVC U pipes are not covered by this standard.
This standard covers a range of nominal sizes and gives recommendations concerning colours.
NOTE 3   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
For external above ground application additional requirements depending on the climatic conditions should be agreed between the manufacturer and the user.
NOTE 4   Pipes conforming to this standard are normally associated with fittings conforming to EN 1329 1. Pipes, fittings and components conforming to any of the product standards listed in Annex C can also be used with pipes conforming to this standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements in Table 11.
NOTE 5   Joints and adhesives are considered to be part of the system as covered in the scope.
NOTE 6   Products conforming to this standard may be submitted to national requirements on fire regulation.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification gives guidance for the assessment of conformity of formulations, products and assemblies in accordance with EN 1453 1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
If certification is involved, it is recommended that the certification body is preferably compliant with EN ISO/IEC 17065 [5] or EN ISO/IEC 17021 [3], as applicable.
In order to help the reader, a basic test matrix is given in Annex A, Table A.1.
In conjunction with EN 1453 1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended to be used for the following purposes:
-   for soil and waste discharge systems (low and high temperature) inside buildings (application area code "B");
This is reflected in the marking of products by "B".

  • Technical specification
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 12200 gives guidance for the assessment of conformity of formulations, products, joints and assemblies in accordance with EN 12200 1:2016 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 12200 1:2016, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended to be used for above ground external rainwater, and to fittings and brackets made of acrylic materials which may be used in combination with the pipes.

  • Technical specification
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 14758 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 14758 1 this document is applicable to solid wall piping systems made of polypropylene modified with mineral(s) (PP-MD) intended to be used for:
—   non-pressure underground drainage and sewerage outside the building structure (application area code “U”); and
—   non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code “D”) and outside the building structure.
This is reflected in the marking of products by “U” and “UD”.

  • Technical specification
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for pipes, fittings, brackets and the system of unplasticized poly(vinyl chloride) (PVC-U) intended for use as above-ground external rainwater piping systems.
It also specifies:
a)   The requirements for metallic brackets.
b)   Both solid wall pipes and fittings, (i.e. product manufactured from a single layer), as well as solid wall multi-layer pipes.
c)   The test parameters for the test methods referred to in this standard.
Pipes can be used in conjunction with fittings and brackets of acrylic materials provided these polymers meet the performance requirements of this standard.
The products are usually used in conjunction with gutters conforming to EN 607 [1]. They are not intended for use with products conforming to EN 612 [2].
This standard is applicable to PVC-U rainwater systems of circular, square, rectangular or any other shape with sealed (rubber ring or solvent cement) or unsealed joints.
This standard covers a range of pipes and fittings sizes.
NOTE 1    It is the responsibility of the purchaser or specifier to make the appropriate selections from the size range to take into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2   The term "rainwater" in this standard is used also to encompass "surface water" (as defined in EN 752 [6]) run-off from buildings.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Report gives the recommended practice for installation of thermoplastics piping systems in the field of soil and waste discharge (low and high temperature) inside buildings (marked with "B") and of soil and waste discharge systems for both inside buildings and buried in ground within the building structure (marked with "BD").
This Technical Report provides material dependent installation techniques but it is important that the general installation practice as given in the relevant parts of EN 12056 for B application are taken into account in manufacturer's instructions, subject to any applicable national and/or local regulations.
This Technical Report is applicable to thermoplastics pipes and fittings as specified in the associated standards EN 1329 1 [1] (PVC-U), EN 1451 1 [2] (PP), EN 1453 1 [3] (PVC-U with structured-wall pipes), EN 1455 1 [4] (ABS), EN 1519 1 [5] (PE), EN 1565 1 [6] (SAN+PVC) and EN 1566 1 [7] (PVC-C), their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following purposes:
a)   soil and waste discharge pipework for the conveyance of domestic waste waters (low and high temperature);
NOTE 1   See Clause 4 for waste discharge temperature limits.
b)   ventilating pipework associated with a);
c)   rainwater pipework within the building structure (see Figure 1, key 16).
It is applicable to pipes and fittings, marked with "B", which are intended to be used above ground only, and to pipes and fittings, marked "BD", which are intended to be used above and buried in ground within the building structure.
NOTE 2   Only those components as specified in the relevant associated standard with nominal outside diameters equal to or greater than 75 mm (marked with "BD") are intended for use buried in ground within the building structure. The term "within building structure" covers all gravity discharge pipework within a building, including the elements installed below the slab and buried in the ground.
If specified in the relevant associated standard, this Technical Report also covers soil and waste discharge pipework fixed externally onto the building (see Figure 1, key 17). It is not applicable to pipework that passes under the building without any connection from the discharge system.
NOTE 3   According to the associated standards, for external above ground soil and waste discharge, additional requirements depending on the climate, will be agreed between the manufacturer and the user.
According to the associated standards, components conforming to other standards on plastic piping systems may be used with pipes and fittings conforming to a given associated standard, if they conform to the requirements for joint dimensions and functional requirements of the given associated standard.

  • Technical report
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 12666 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001:2008 [1].
NOTE 2   If third-party certification is involved, it is recommended that the certification body is accredited to EN 45011 [2], EN 45012 [3] or EN ISO/IEC 17021 [4], as applicable.
NOTE 3    In order to help the readers, a summary of the test regime is given in Annex A.
In conjunction with EN 12666-1 (see Foreword) this document is applicable to piping systems made of polyethylene (PE):
-   non-pressure underground drainage and sewerage outside the building structure (application area code "U"), reflected in the marking of products by "U", and
-   for non-pressure underground drainage and sewerage for both buried in the ground within the building structure (application area code "D") and outside the building structure (application area code "U"), reflected in the marking of products by "UD".

  • Technical specification
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the mounting and fixing of components in the test apparatus to thermal attack by a single burning item (SBI) according to EN 13823.
This document is applicable to non-pressure plastics pipes, fittings and their joints intended for soil and waste applications:
-   inside the building (application area code "B");
-   buried in ground within the building structure (application area code "BD") and with a diameter greater than or equal to 75 mm.
It is also applicable to pressure plastics pipes, fittings and their joints within the building structure:
-   intended for water for general purposes, drainage, sewerage, as well as for any other pressure application with other fluids covered by the Construction Products Directive;
-   hot and cold water installations for the conveyance of water and for heating systems.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies a method for determining the resistance to internal pressure of polyethylene (PE) pipes after being subjected to a sqeeze-off procedure and then tested for hydrostatic strength.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies a method for the determination of moisture content in plastics. This method is only applicable to thermoplastics for which the melting point is below 160°C. The method is suitable for measuring the moisture content down to 0,005 %. This method determines the total moisture content in the test piece and includes surface moisture and moisture contained within the test piece. Because the test piece is converted to a molten state, it is assumed that all moisture is expelled.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies a method for determining the content of material volatile at 105 °C in polyethylene (PE) piping materials. This method is applicable to moulding and extrusion materials. It also can be applicable to components in PE piping systems.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies a test method for the resistance to impact of polyethylene (PE) tapping tees. This standard is applicable to PE tapping tees intended for the transport of fluids.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC U) piping systems in the field of non-pressure underground drainage and sewerage:
- buried in ground outside the building structure (application area code "U"), and
- both buried in ground, within the building structure and outside the building (application area code "UD").
NOTE 1   The intended use is reflected in the marking of products by "U" or "UD".
It also specifies the test parameters for the test methods referred to in this document.
NOTE 2   Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 13476-2 [1].
This document covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours.
NOTE 3   It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
It is applicable to PVC U pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
NOTE 4   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 16.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 1852 specifies the requirements for solid wall pipes with smooth internal and external surfaces extruded from the same compound/formulation throughout the wall, fittings and the system of polypropylene (PP) piping systems intended for use for:
-   non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
-   non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
This standard covers PP materials without mineral modifiers.
It also specifies the test parameters for the test methods referred to in this standard.
NOTE 1 Solid wall multilayer pipes with different formulation throughout the wall and foamed core pipes are covered by EN 13476-2 [1] (see also CEN ISO/TR 27165 [2]).
This standard covers a range of nominal sizes, and pipe series and gives recommendations concerning colours.
NOTE 2   It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with CEN/TS 1852-2, it is applicable to PP pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
The fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.
NOTE 3   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be connected to pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 14.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification gives guidance for the assessment of conformity of materials (compounds/formulations), products and assemblies in accordance with EN 1566 1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third-party certification is involved, it is recommended that the certification body is accredited to EN 45011 [2], EN 45012 [3] or EN ISO/IEC 17021 [4], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1566 1, this document is applicable to solid-wall piping systems made of chlorinated poly(vinyl chloride) (PVC C) intended to be used for the following purposes:
-   for soil and waste discharge systems (low and high temperature) inside buildings (application area code "B");
-   for soil and waste discharge systems (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD").
NOTE 4   This is reflected in the marking of products by "B" or "BD".

  • Technical specification
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Specification gives guidance for the assessment of conformity of materials (compounds/formulations), products and assemblies in accordance with EN 1455 1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1   It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2   If third-party certification is involved, it is recommended that the certification body is accredited to EN 45011 [2], EN 45012 [3] or EN ISO/IEC 17021 [4], as applicable.
NOTE 3   In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1455 1, this document is applicable to solid wall piping systems made of acrylonitrile-butadiene-styrene (ABS) intended to be used for the following purposes:
-   for soil and waste discharge (low and high temperature) inside buildings (application area code "B");
-   for soil and waste discharge (low and high temperature) inside buildings and buried in ground within the building structure (application area code "BD").
NOTE 4   This is reflected in the marking of products by "B" or "BD".

  • Technical specification
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for pipes, fittings and the system of acrylonitrile-butadiene-styrene (ABS) and acrylonitrile-styrene-acrylester (ASA) solid-wall piping systems in the field of soil and waste discharge (low and high temperature) - inside buildings (marked with "B") - for both inside buildings and buried in ground within the building structure (marked with "BD").

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the requirements for pipes, fittings and the piping system of chlorinated poly(vinyl chloride) (PVC-C) solid-wall piping systems in the field of soil and waste discharge (low and high temperature) inside buildings (marked with "B") and for soil and waste discharge systems for both inside buildings and buried in ground within the building structure (marked with "BD"). Note 1: The application area "inside buildings" according to this standard, applies to the interior area of the building only.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 1852 specifies the requirements for solid wall pipes with smooth internal and external surfaces extruded from the same compound/formulation throughout the wall, fittings and the system of polypropylene (PP) piping systems intended for use for:
-   non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
-   non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
This standard covers PP materials without mineral modifiers.
It also specifies the test parameters for the test methods referred to in this standard.
NOTE 1 Solid wall multilayer pipes with different formulation throughout the wall and foamed core pipes are covered by EN 13476-2 [1] (see also CEN ISO/TR 27165 [2]).
This standard covers a range of nominal sizes, and pipe series and gives recommendations concerning colours.
NOTE 2   It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with CEN/TS 1852-2, it is applicable to PP pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
The fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.
NOTE 3   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be connected to pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 14.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day