prEN 13203-4
(Main)Gas fired domestic appliances producing hot water - Part 4: assessment of energy consumption of gas fired appliances combined heat and power (micro CHP) producing hot water and electricity not exceeding 70 kW heat input, not exceeding 50 kWe electrical output and 500 l water storage capacity
Gas fired domestic appliances producing hot water - Part 4: assessment of energy consumption of gas fired appliances combined heat and power (micro CHP) producing hot water and electricity not exceeding 70 kW heat input, not exceeding 50 kWe electrical output and 500 l water storage capacity
This European Standard is applicable to gas-fired micro CHP appliances producing domestic hot water and electricity. The electricity is generated in a process linked to the production of useful heat.
It applies to a system marketed as single unit or a system fully specified by a manufacturer that have:
- a gas heat input not exceeding 70 kW;
- an electrical output not exceeding 50 kWe; and
- a hot water storage capacity not exceeding 500 litres.
This European Standard EN 13203 is formed in four parts which cover aspects of domestic hot water production.
Standard EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a selected variety of uses. It also gives a system for presenting the information to the user. This first part complements EN 26, EN 89 and EN 625.
Standard EN 13203-2 sets out a method for assessing the energy performance of the appliances. It defines a number of daily tapping cycles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user.
Standard EN 13203-3 deals with solar systems.
Note : a draft standard prEN 13203-5 for "Gas-fired domestic appliance producing hot water - Part 5 : Assessment of energy consumption of gas fired appliances combined with electrical heat pump not exceeding 70 kW heat input and 300 l water storage capacity" is also under preparation by CEN/TC109/WG4.
All standards and drafts series EN 13203 are worked out under Mandate M324 against Energy Labelling Directive 92/75/EC under revision.
Gasbefeuerte Geräte für die sanitäre Warmwasserbereitung für den Hausgebrauch - Teil 4: Bewertung des Energieverbrauchs von Gasgeräten mit Kraft-Wärme-Kopplung (KWK) zur Warmwasserbereitung und Stromerzeugung, die eine Nennwärmebelastung von 70 kW, eine elektrische Leistung von 50 kWe und eine Speicherkapazität von 500 Liter Wasser nicht überschreiten
Diese Europäische Norm ist anwendbar auf gasbefeuerte KWK-Geräte, die sanitäres Warmwasser für den Hausgebrauch und elektrische Energie bereitstellen. Die elektrische Energie wird in Verbindung mit Nutz-wärme erzeugt.
Sie ist anzuwenden auf Geräte, die als Einheit vermarktet werden oder für Systeme, die von einem Hersteller umfassend beschrieben sind und:
- eine Wärmebelastung von 70 kW nicht überschreiten,
- eine elektrische Leistung von 50 kWe nicht überschreiten und
- ein Warmwasserspeichervolumen von 500 l nicht überschreiten.
Diese Europäische Norm EN 13203 enthält vier Teile, die die Aspekte der sanitären Warmwasserbereitung für den Hausgebrauch abdecken.
EN 13203-1 legt mehrere quantitative und qualitative Niveaus für den Komfort von sanitärem Warmwasser für eine Auswahl von Benutzungsarten fest. Er enthält ebenfalls Hinweise zur entsprechenden Information des Betreibers. Dieser erste Teil vervollständigt EN 26, EN 89 und EN 625. EN 13203-2 legt eine Methode zur Bewertung des Energieverhaltens von Geräten fest. Sie definiert eine Anzahl täglicher Zapfprogramme für die häusliche Warmwasser-Verwendung in der Küche, zum Duschen und Baden und für Kombinationen dieser Verwendungsarten. Weiterhin legt sie die entsprechenden Prüfverfahren fest, mit denen das Energieverhalten unterschiedlicher Geräte verglichen und auf die Bedürfnisse des Betreibers ausgerichtet werden kann.
prEN 13203-3 legt eine Methode zur Bewertung des Energieverbrauchs eines solarunterstützten Gerätes fest, das Warmwasser für den sanitären Hausgebrauch bereitstellt.
Dieser Teil 4 legt eine Methode zur Bewertung des Energieverbrauchs einer gasbefeuerten KWK-Anlage fest.
Appareils domestiques produisant de l'eau chaude sanitaire utilisant les combustibles gazeux - Appareils à gaz de production combinée de chaleur et d'électricité (micro CHP) produisant de l'eau chaude et de l'électricité de débit calorifique inférieur ou égal à 70 kW de capacité de stockage inférieure ou égal à 500 litres - Partie 4: Évaluation de la consommation énergétique
La présente Norme européenne s’applique aux appareils micro-cogénération (micro CHP) de production d'eau chaude sanitaire et d’électricité utilisant les combustibles gazeux. L’électricité est produite par un procédé relatif à la production de chaleur.
Elle s’applique à la fois aux ensembles commercialisés comme une unité seule et aux ensembles entièrement spécifiés par le fabricant dont :
- le débit calorifique gaz est inférieur ou égal à 70 kW ;
- la puissance électrique est inférieure ou égale à 50 kWe ;
- la capacité de stockage en eau est inférieure ou égale à 500 litres.
La norme EN 13203 est composée de quatre parties qui couvrent les aspects de la production de l'eau chaude sanitaire.
La norme EN 13203-1 définit en termes qualitatifs et quantitatifs la performance en puisage d'eau chaude sanitaire pour une variété d’usages sélectionnée. Elle fournit également des informations destinées à l’utilisateur. Cette partie complète l’EN 26, l’EN 89 et l'EN 625.
La norme EN 13203-2 définit une méthode pour déterminer les performances énergétiques des appareils. Elle définit cinq cycles de puisage journaliers pour l’usage d'eau chaude sanitaire, cuisine, douche, bain, et une combinaison de ces derniers, ainsi que les modalités d'essais correspondants, afin de pouvoir établir une comparaison des performances énergétiques des appareils utilisant les combustibles gazeux selon les besoins de l’utilisateur.
Le PR EN 13203-3 traite de l'évaluation de la consommation énergétique des appareils à gaz de production d'eau chaude couplés à un système solaire.
La présente partie 4 définit une méthode d’évaluation de la consommation énergétique des appareils à gaz micro-cogénération (micro CHP).
Plinske gospodinjske naprave za pripravo sanitarne tople vode - 4. del: Ocenjevanje rabe energije mikro soproizvodnih naprav za toplo vodo in elektriko do toplotne moči 70 kW, do vključno 50 kWe električne moči in hranilnikom vode do 500 l
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2011
3OLQVNHJRVSRGLQMVNHQDSUDYH]DSULSUDYRVDQLWDUQHWRSOHYRGHGHO
2FHQMHYDQMH]PRJOMLYRVWLUDEHHQHUJLMHPLNURVRSURL]YRGQLKQDSUDY]DWRSORYRGR
LQHOHNWULNR
GRWRSORWQHPRþLN:GRYNOMXþQRN:HHOHNWULþQHPRþLLQKUDQLOQLNRPYRGH
GRO
Gas fired domestic appliances producing hot water - Part 4: assessment of energy
consumption of gas fired appliances combined heat and power (micro CHP) producing
hot water and electricity not exceeding 70 kW heat input, not exceeding 50 kWe
electrical output and 500 l water storage capacity
Gasbefeuerte Geräte für die sanitäre Warmwasserbereitung für den Hausgebrauch - Teil
4: Bewertung des Energieverbrauchs von Gasgeräten mit Kraft-Wärme-Kopplung (KWK)
zur Warmwasserbereitung und Stromerzeugung, die eine Nennwärmebelastung von 70
kW, eine elektrische Leistung von 50 kWe und eine Speicherkapazität von 500 Liter
Wasser nicht überschreiten
Appareils domestiques produisant de l'eau chaude sanitaire utilisant les combustibles
gazeux - Appareils à gaz de production combinée de chaleur et d'électricité (micro CHP)
produisant de l'eau chaude et de l'électricité de débit calorifique inférieur ou égal à 70
kW de capacité de stockage inférieure ou égal à 500 litres - Partie 4: Évaluation de la
consommation énergétique
Ta slovenski standard je istoveten z: prEN 13203-4
ICS:
91.140.65 Oprema za ogrevanje vode Water heating equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
DRAFT
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2010
ICS 91.140.65
English Version
Gas fired domestic appliances producing hot water - Part 4:
assessment of energy consumption of gas fired appliances
combined heat and power (micro CHP) producing hot water and
electricity not exceeding 70 kW heat input, not exceeding 50
kWe electrical output and 500 l water storage capacity
Appareils domestiques produisant de l'eau chaude sanitaire Gasbefeuerte Geräte für die sanitäre
utilisant les combustibles gazeux - Appareils à gaz de Warmwasserbereitung für den Hausgebrauch - Teil 4:
production combinée de chaleur et d'électricité (micro CHP) Bewertung des Energieverbrauchs von Gasgeräten mit
produisant de l'eau chaude et de l'électricité de débit Kraft-Wärme-Kopplung (KWK) zur Warmwasserbereitung
calorifique inférieur ou égal à 70 kW de capacité de und Stromerzeugung, die eine Nennwärmebelastung von
stockage inférieure ou égal à 500 litres - Partie 4: 70 kW, eine elektrische Leistung von 50 kWe und eine
Évaluation de la consommation énergétique Speicherkapazität von 500 Liter Wasser nicht überschreiten
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 109.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 13203-4:2010: E
worldwide for CEN national Members.
Contents Page
Foreword .3
1 Scope .3
2 Normative references .3
3 Definitions .4
4 General test conditions .5
4.1 Reference conditions .5
4.2 Measurement uncertainties .5
4.3 Test conditions .6
4.3.1 General .6
4.3.2 Test room .6
4.3.3 Water supply .6
4.3.4 Steady state .7
4.3.5 Initial adjustment of the appliance .7
4.3.6 Electrical supply .7
4.3.7 Electrical energy output .7
5 Determination of the energy consumption and electrical energy generation of appliances.7
5.1 General .7
5.2 Tapping cycles .7
5.2.1 General .7
5.2.2 Test for determination of the daily energy consumption . 14
Annex A (informative) Test conditions . 21
Annex B (informative) Test rig and measurement devices . 24
B.1 General . 24
B.2 Pressure measurement . 25
B.3 Temperature measurement . 25
Foreword
This document (prEN 13203-4:2010) has been prepared by Technical Committee CEN/TC 109 “Central heating
boilers using gaseous fuels”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association, and supports essential requirements of EU Directive(s).
1 Scope
This European Standard is applicable to gas-fired micro CHP appliances producing domestic hot water and
electricity. The electricity is generated in a process linked to the production of useful heat.
It applies to a package marketed as single unit or a package fully specified by a manufacturer that have :
a gas heat input not exceeding 70 kW;
an electrical output not exceeding 50 kWe and
a hot water storage capacity not exceeding 500 litres.
This European Standard EN 13203 is formed in four parts which cover aspects of domestic hot water production.
Standard EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic hot
water for a selected variety of uses. It also gives a system for presenting the information to the user. This first part
complements EN 26, EN 89 and EN 625. Standard EN 13203-2 sets out a method for assessing the energy
performance of the appliances. It defines a number of daily tapping cycles for each domestic hot water use,
kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the
energy performances of different gas-fired appliances to be compared and matched to the needs of the user.
PR EN 13203-3 deals with the assessment of energy consumption of solar supported gas-fired domestic
appliances producing hot water.
This Part 4 sets out a method for assessing the energy performance of gas fired micro CHP appliances.
2 Normative references
The following referenced documents are indispensable for the application of this European Standard. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
EN 26, Gas-fired instantaneous water heaters for the production of domestic hot water, fitted with atmospheric
burners
EN 89, Gas-fired storage water heaters for the production of domestic hot water
EN 625, Gas-fired central heating boilers - Specific requirements for the domestic hot water operation of
combination boilers of nominal heat input not exceeding 70 kW
EN 13203-1, Gas-fired domestic appliances producing hot water – Appliances not exceeding 70 kW heat input and
300 litres water storage capacity. Part 1 : Assessment of performance of hot water deliveries
EN 13203-2, Gas-fired domestic appliances producing hot water – Appliances not exceeding 70 kW heat input and
300 litres water storage capacity. Part 2 : Assessment of energy consumption
PR EN 13203-3, Solar supported gas-fired domestic appliances producing hot water – Appliances not exceeding
70 kW heat input and 500 litres water storage capacity. Part 3 : Assessment of energy consumption
3 Definitions
For the purposes of this standard, the following definitions apply.
3.1
control cycle
the time cycle for keeping components and/or the tank (if any) of the domestic hot water circuit at predetermined
temperature level, consists of an «ON» duration time during which the heating of the domestic hot water (by gas
energy and/or auxiliary energy) is operating, and an «OFF» duration time during which no heating occurs
3.2
domestic water mean temperature
the average temperature of the water delivered during the time ∆t
T = T ⋅ dt
m
∫
∆t
SYMBOL T
m
3.3
domestic water test temperature
temperature of the delivered water at which the tests are conducted
3.4
nominal domestic hot water heat input
value of the heat input stated by the manufacturer for the production of domestic hot water
SYMBOL Q
nw
NOTE Q is expressed in kilowatt (kW)
nw
3.5
off mode
state of an appliance, selected by the user, in which hot sanitary water can not be provided.
3.6
stand by mode
operating state in which the appliance can provide hot sanitary water at any time.
in the case of an appliance with a control cycle for keeping components and/or the tank (if any) of the domestic hot
water circuit at predetermined temperature level no tapping is made.
3.7
summer mode
conditions during which the appliance supplies energy only for the production of domestic hot water
3.8
tank
reservoir for domestic hot water and or central heating water
The manufacturer is the organisation or company which assumes responsibility for the product.
3.9
useful water
quantity of water delivered for which the temperature increase is in accordance with the requirement fixed for each
individual delivery of the tapping cycles
3.10
wasted water
quantity of water delivered for which the temperature increase is not in accordance with the requirement fixed for
each individual delivery of the tapping cycles
3.11
winter mode
conditions during which the appliance supplies energy for the production of domestic hot water and/or space
heating
4 General test conditions
4.1 Reference conditions
Unless otherwise stated, the general test conditions are as follows :
cold water temperature: (10 ± 2) °C;
cold water pressure: (2 ± 0,1) bar;
ambient air temperature: (20 ± 3) °C;
electrical supply voltage:
(230 ± 2) V single phase;
(400 ± 4) V three phase.
electrical output voltage :
(230 ± 2) V single phase;
(400 ± 4) V three phase.
4.2 Measurement uncertainties
Except where otherwise stated in the clauses describing the tests, the uncertainties of measurements carried out
shall be not greater than the maximum uncertainties indicated below.
These uncertainties correspond to two standard deviations.
The laboratory evaluates these standard deviati
...