The scope of this European Standard is to define the classification for horizontal closed ice-cream freezers and to specify their requirements and test methods. These appliances are different to supermarket segment freezers, as they work with static air cooling, with a skin evaporator (no evaporator fan) and are used specifically for the storage and display of pre-packed ice-cream. This standard is only applicable to integral type refrigeration systems. This standard is not applicable to remote and secondary system type cabinets. Ice-cream freezers within this standard should have a net volume ≤ 600 l and only for transparent lid ice cream freezers they should have a Net Volume/TDA ≥ 0,35 m.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the rating conditions, tolerances and presentation of manufacturer's performance data for condensing units for refrigeration with compressors of the positive-displacement type. These include single stage compressors and single and two stage compressors having an integrated means of fluid sub cooling. This is required so that a comparison of different condensing units can be made. The data relate to the refrigerating capacity and power absorbed and include requirements for part-load performance where applicable.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 15181:2007+A1specifies the method of test for determining the gas energy consumption in gas-fired domestic ovens when they are being used in one or more of the oven cooking modes defined in 3. 1. It applies to the gas-fired domestic ovens which are capable of utilizing gases of group H or group E !or third family gases", possibly after conversion according to instructions for use.This European Standard applies to these gas-fired domestic ovens, whether they are separate appliances or component parts of domestic cooking appliances.This European Standard also applies to domestic appliances that can utilize gas and/or electrical energy to provide heat for cooking when the ovens are utilizing gas energy to provide heat for cooking, but not when electric energy is used to provide any or all of the heat for cooking in the oven.It is not applicable to:- microwave combination ovens;- small cavities ovens (3.2);- oven cavities not provided with devices to detect and control the temperature for the preparation of food;- cooking modes others than defined in 3.1.1 and 3.1.2;- ovens connected to a chimney in which the gas energy for cooking provides, by design, also space and/or water heating;!Deleted text"This European Standard is concerned neither with safety nor with overall performance requirements.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of prEN 16905
This European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as "GEHP appliance".
This European Standard only applies to GEHP appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This standard only applies to GEHP appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2003+A1:2009.
This standard only applies to GEHP appliances having:
a)   gas fired endothermic engines under the control of fully automatic control systems;
b)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 ºC during normal operation;
d)   where the maximum operating pressure in the
1)   heating water circuit (if installed) does not exceed 6 bar
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
The GEHP appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard.
The above GEHP appliances can have one or more primary or secondary functions.
This European Standard is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.
In the case of packaged units (consisting of several parts), the standard applies only to those designed and supplied as a complete package.
NOTE   All the symbols given in this text are used regardless of the language used.
1.2   Scope of prEN 16905-2
This part of prEN 16905 specifies the safety requirements, the safety test conditions and the safety test methods of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of prEN 16905
This European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as "GEHP appliance".
This European Standard only applies to GEHP appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This standard only applies to GEHP appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2003+A1:2009.
This standard only applies to GEHP appliances having:
a)   gas fired endothermic engines under the control of fully automatic control systems;
b)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 ºC during normal operation;
d)   where the maximum operating pressure in the
1)   heating water circuit (if installed) does not exceed 6 bar
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
The GEHP appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard.
The above GEHP appliances can have one or more primary or secondary functions.
This European Standard is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.
In the case of packaged units (consisting of several parts), the standard applies only to those designed and supplied as a complete package.
NOTE   All the symbols given in this text are used regardless of the language used.
1.2   Scope of prEN 16905-2
This part of prEN 16905 specifies the safety requirements, the safety test conditions and the safety test methods of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and testing for ratings and performance of air handling units as a whole. It also specifies requirements, recommendations, classification, and testing of specific components and sections of air handling units. For many components and sections it refers to component standards, but it also specifies restrictions or applications of standards developed for stand alone components.
This standard is applicable both to standardised designs, which may be in a range of sizes having common construction concepts, and also to custom-design units. It also applies both to air handling units, which are completely prefabricated, and to units which are built up on site. Generally the units within the scope of this standard include at least a fan, a heat exchanger and an air filter.
This standard is not applicable to the following:
a)   air conditioning units serving a limited area in a building, such as fan coil units;
b)   units for residential buildings;
c)   units producing ventilation air mainly for a manufacturing process.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and testing for rating and performance of Non Residential Ventilation Units, NRVU’s, specifically Air Handling Units (AHU’s). It specifies requirements, classifications and testing of components and sections of air handling units.
This document applies to tests in a laboratory and in situ. This document is applicable both for mass produced air handling units and tailor-made Air Handling Units.
This document applies to AHU and individual sections of AHU with the designed air flow > 250 m3 · h−1. This document applies to UVU's with additional air treatment components in addition to filtration.
This standard does not include:
-   residential unidirectional and bidirectional ventilation units;
-   nonresidential unidirectional ventilation units which consist of only a casing, a fan with or without filter.
NOTE 1   Residential ventilation units are covered by EN 13142.
NOTE 2   Nonresidential unidirectional ventilation units which consists only casing, fan with or without filter are covered by EN 17291.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for energy assessment of un-vented (closed) hot water storage tanks with a capacity up to 1 500 l, intended to be equipped with an external heat source and used for domestic hot water production. Whilst storage water heaters intended primarily for direct heating are not covered by this European Standard, it does allow the provision of electric heating elements for auxiliary use.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for measurement of electrical, photometric, and colorimetric quantities of LED lamps, modules, light engines and luminaires, for operation with AC or DC supply voltages, possibly with associated control gear. Photometric and colorimetric quantities covered in this standard include total luminous flux, luminous efficacy, partial luminous flux, luminous intensity distribution, centre-beam intensities, luminance and luminance distribution, chromaticity coordinates, correlated color temperature (CCT), Color Rendering Index (CRI), and spatial uniformity of chromaticity.
This standard does not cover LED packages and products based on OLEDs (organic LEDs).
NOTE   Where the term "LED product, LED device or DUT (device under test)" is used, the term covers LED lamps, modules, light engines or luminaires.

  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the energy assessment of domestic/sanitary hot water storage tanks of up to 2 000 l.
Whilst this document does not cover water heaters intended primarily for direct heating, it does allow the provision of electric heating elements for auxiliary use.
Primary heating buffer tanks are not covered by this document. Heat losses of domestic hot water storage tanks integrated into combi boilers marketed as a single unit are not covered by this document.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard is composed of two parts.
The first part supplements EN 303 1, EN 303 2, EN 303 4 and EN 304 hereafter called boiler standards. It specifies the supplementary requirements and tests for the construction, safety, rational use of energy, fitness for purpose, classification and marking related to the domestic hot water operation of oil fired water heaters and combination boilers.
The domestic hot water is produced on either the instantaneous or storage principle. The domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
The second part covers the energy performance of domestic hot water production of the appliances covered by the first part.
This second part sets out a method for assessing the energy performance of the appliances. It defines a number of daily tapping cycles for each domestic hot water use such as kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of combination boilers and water heaters to be compared and matched to the needs of the user.
The heat output of the appliances covered by this standard does not exceed 400 kW.
In the case of combination boilers, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
This standard only covers type testing.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Standard specifies requirements for the verification of performance including energy consumption of refrigerated storage cabinets and counters for professional use in commercial kitchens, hospitals, canteens, preparation areas of bars, bakeries, gelateria, institutional catering and similar professional areas.
The products covered in this Standard are intended to store foodstuffs. It specifies test conditions and methods for checking that the requirements have been satisfied, as well as classification of the cabinets and counters, their marking and the list of their characteristics to be declared by the manufacturer.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies classification, requirements for the construction, performance and energy consumption testing of gelato scooping cabinets and pozzetto used to sale and/or display artisan and self made gelato. It specifies test conditions and methods for checking that the requirements have been satisfied, their marking and the list of their characteristics to be declared by the manufacturer.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is composed of two parts.
The first part supplements EN 303-1, EN 303-2, EN 303-4 and EN 304, hereafter called boiler standards. It specifies the supplementary requirements and tests for the construction, safety, rational use of energy, fitness for purpose, classification and marking related to the domestic hot water operation of oil-fired water heaters and combination boilers.
The domestic hot water is produced on either the instantaneous or storage principle. The domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
The second part covers the energy performance of domestic hot water production of the appliances covered by the first part.
This second part sets out a method for assessing the energy performance of the appliances. It defines a number of daily tapping cycles for each domestic hot water use such as kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of combination boilers and water heaters to be compared and matched to the needs of the user.
The heat output of the appliances covered by this standard does not exceed 400 kW.
In the case of combination boilers, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
This standard only covers type testing.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies classification, requirements for the construction, performance and energy consumption testing of gelato scooping cabinets and pozzetto used to sale and/or display artisan and self made gelato. It specifies test conditions and methods for checking that the requirements have been satisfied, their marking and the list of their characteristics to be declared by the manufacturer.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for measurement of electrical, photometric, and colorimetric quantities of LED lamps, modules, light engines and luminaires, for operation with AC or DC supply voltages, possibly with associated control gear. Photometric and colorimetric quantities covered in this standard include total luminous flux, luminous efficacy, partial luminous flux, luminous intensity distribution, centre-beam intensities, luminance and luminance distribution, chromaticity coordinates, correlated color temperature (CCT), Color Rendering Index (CRI), and spatial uniformity of chromaticity.
This standard does not cover LED packages and products based on OLEDs (organic LEDs).
NOTE   Where the term "LED product, LED device or DUT (device under test)" is used, the term covers LED lamps, modules, light engines or luminaires.

  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the verification of performance and energy consumption of refrigerated storage cabinets and counters for professional use in commercial kitchens, hospitals, canteens, preparation areas of bars, bakeries, gelateria, institutional catering and similar professional areas.
The products covered in this document are intended to store foodstuffs. It specifies test conditions and methods for checking that the requirements have been satisfied, as well as classification of the cabinets and counters, their marking and the list of their characteristics to be declared by the manufacturer.
It is not applicable to:
— refrigerated cabinets used in the direct sale of foodstuffs;
— cabinets that carry out food processing and not just storage function (e.g. bakery cabinets that chill, heat and humidify);
— cabinets with water cooled condenser;
— appliances with remote condensing unit;
— appliances with open top tables and saladettes for preparation or storage of foodstuffs;
— cabinets specifically intended for storage of specific foodstuffs (i.e. fresh meat, fresh fish, etc.) operating at a temperature different from those specified in Table 1;
— chest freezers;
— appliances intended for short time /intermittent normal operation during the full day;
— built-in cabinets;
— roll-in cabinets;
— pass-through cabinets;
— ice cream freezers.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies methods for testing the sound power level for water heating energy efficiency of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production.
This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system.
NOTE 1   Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous means that domestic hot water production and space heating generation occur at the same time and may interact.
NOTE 2   For space heating functions, the requirements are given in EN 12102-1.
This European Standard only applies to water heaters which are supplied in a package of heat pump and storage tank. In the case of water heaters consisting of several parts with refrigerant connections, this European Standard applies only to those designed and supplied as a complete package.
This European Standard does not specify requirements of the quality of the used water

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for testing the sound power level of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production.
This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system.
NOTE 1   Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous operation means that domestic hot water production and space heating generation occur at the same time and may interact.
NOTE 2   For space heating function, the requirements are given in EN 12102-1:2017.
This European Standard only applies to water heaters which are supplied in a package of heat pump and storage tank. In the case of water heaters consisting of several parts with refrigerant connections, this European Standard applies only to those designed and supplied as a complete package.
This European Standard does not specify requirements for the quality of the used water.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both
instantaneous and storage gas-fired appliances combined with electrical heat pump.
It applies to a package marketed as single unit or fully specified by a manufacturer that have:
- a gas heat input not exceeding 70 kW;
- a hot water storage capacity not exceeding 500 litres.
Standard EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic
hot water for a selected variety of uses. It also gives a system for presenting the information to the user. This
Part 5 sets out a method for assessing the energy performance of gas fired appliances combined with heat
pump with electrically driven compressor according to EN 16147.
This European standard does not apply for gas boilers with recovery systems using combustion products as
heat source for the electrical heat pump.
When the electrical heat pump does not work for domestic hot water production in the summer period, the
present standard is not applicable for energy performances assessing, EN 13203-2 must be used.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers air conditioners, heat pumps and liquid chilling packages, including comfort and process chillers. It applies to factory made units defined in EN 14511-1, except single duct, double duct, control cabinet and close control units. It also covers direct expansion-to-water(brine) heat pumps (DX-to-water) as defined in EN 15879-1.
This European Standard also covers hybrid heat pumps as defined in this standard.
This European Standard gives the temperatures and part load conditions and the calculation methods for the determination of seasonal energy efficiency SEER and SEERon, seasonal space cooling energy efficiency ηs,c seasonal coefficient of performance SCOP, SCOPon and SCOPnet, and seasonal space heating energy efficiency ηs,h and seasonal energy performance ratio SEPR.
Such calculation methods may be based on calculated or measured values.
In case of measured values, this European Standard covers the test methods for determination of capacities, EER and COP values during active mode at part load conditions. It also covers test methods for electric power consumption during thermostat-off mode, standby mode, off-mode and crankcase heater mode.
NOTE 1 The word "unit" is used instead of the full terms of the products.
NOTE 2 The word "cooling" is used to refer to both space cooling and process cooling.
NOTE 3 The word "heating" is used to refer to space heating.

  • Standard
    133 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard provides test or calculation methods to assess thermal insulation performances for customized walk-in cold rooms and components under normal end-use conditions.
The normal end-use conditions of a walk-in cold room are considered to be:
-   installation inside an existing building;
-   not exposed to external weather conditions;
-   internal side of panels subject to temperatures within the indicative range −40 °C ≤ T ≤ 12 °C;
-   external side of panels subject to temperatures within the indicative range −8 °C ≤ T ≤ 30 °C; temperatures below 0 °C, or higher than 20 °C, can be reached if the walk-in cold room is located inside not air-conditioned premises.
NOTE   In case the customized walk-in cold room working at medium storage temperature is used as a food processing room or a clean room, the standard is applied.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers air conditioners, heat pumps and liquid chilling packages, including comfort and process chillers. It applies to factory made units defined in EN 14511-1, except single duct, double duct, control cabinet and close control units. It also covers direct expansion-to-water(brine) heat pumps (DX-to-water) as defined in EN 15879-1.
This European Standard also covers hybrid heat pumps as defined in this standard.
This European Standard gives the temperatures and part load conditions and the calculation methods for the determination of seasonal energy efficiency SEER and SEERon, seasonal space cooling energy efficiency ηs,c seasonal coefficient of performance SCOP, SCOPon and SCOPnet, and seasonal space heating energy efficiency ηs,h and seasonal energy performance ratio SEPR.
Such calculation methods may be based on calculated or measured values.
In case of measured values, this European Standard covers the test methods for determination of capacities, EER and COP values during active mode at part load conditions. It also covers test methods for electric power consumption during thermostat-off mode, standby mode, off-mode and crankcase heater mode.
NOTE 1 The word "unit" is used instead of the full terms of the products.
NOTE 2 The word "cooling" is used to refer to both space cooling and process cooling.
NOTE 3 The word "heating" is used to refer to space heating.

  • Standard
    133 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both instantaneous and storage gas-fired combined with electrical heat pump.
It applies to a package marketed as single unit or fully specified by the manufacturer that have:
- a heat input not exceeding 400 kW; and
- a hot water storage tank capacity (if any) not exceeding 2000 l.
EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a selected variety of uses. It also gives a system for presenting the information to the user. The present document sets out a method for assessing the energy performance of gas fired appliances combined with heat pump with electrically driven compressor according to EN 16147. It defines a number of daily load profiles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user. Where other technologies are combined with a gas-fired boiler or a water heater to produce domestic hot water, specific parts of EN 13203 apply.
The present document does not apply for gas boilers with recovery systems using combustion products as heat source for the electrical heat pump.
When the electrical heat pump does not work for domestic hot water production in the summer period, the present standard is not applicable for energy performances assessing, EN 13203-2 should be used.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides test or calculation methods to assess thermal insulation performances for customized walk-in cold rooms and components under normal end-use conditions.
The normal end-use conditions of a walk-in cold room are considered to be:
- installation inside an existing building;
- not exposed to external weather conditions;
- internal side of panels subject to temperatures within the indicative range −40 °C ≤ T ≤ 12 °C;
- external side of panels subject to temperatures within the indicative range −8 °C ≤ T ≤ 30 °C; temperatures below 0 °C, or higher than 20 °C, can be reached if the walk-in cold room is located inside not air-conditioned premises.
NOTE In case the customized walk-in cold room working at positive storage temperature is used as a food processing room or a clean room, the standard is applied.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies performance test methods for control equipment. Furthermore, this document contains requirements on accuracy, durability and reliability of control equipment.
The tests described in this document are limited to electrically activated components delivered with or for the system by the final supplier. For the purposes of this document controller and control equipment for solar heating systems and auxiliary heaters, if part of the system, are restricted to the following:
a)   Controllers as:
1)   system clocks, timers and counters;
2)   differential thermostats;
3)   multi-function controllers.
b)   Sensors as:
1)   temperature sensors;
2)   irradiance sensors (for short wave radiation);
3)   pressure sensors;
4)   level sensors;
5)   flow meters;
6)   heat meters.
c)   Actuators as:
1)   pumps;
2)   solenoid and motor valves;
3)   relays.
d)   Combinations of controllers, sensors and actuators listed above.
An additional objective of the procedures described in this document is to verify control algorithms and, together with the accuracy of sensors, to determine control parameters. In addition to verifying the functioning of a controller, its equipment and actuators, the determined parameters may be used for numerical system simulations.
Typically, electrical anodes are not part of the control equipment and are not controlled by the control equipment. However, because they are electrical appliances, electrical anodes are included in this document.
This document is valid for control equipment of solar heating systems for the purpose of hot water preparation and/or space heating. If the solar system is connected to or part of a conventional heating system, the validity is extended to the entire system. In combination with the standards EN 12976-1, EN 12976-2 as well as EN 12977-1, EN 12977-2, EN 12977-3 and EN 12977-4, this document is valid for
e) factory made solar heating systems,
f) small custom built solar heating systems,
g) large custom built solar heating systems,
h)   auxiliary heater equipment used in connection with e), f) and g).

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements on durability, reliability and safety of small and large custom built solar heating and cooling systems with liquid heat transfer medium in the collector loop for residential buildings and similar applications.
This document also contains requirements on the design process of large custom built systems.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to small and large custom built solar heating systems with liquid heat transfer medium for residential buildings and similar applications, and gives test methods for verification of the requirements specified in EN 12977-1.
This document also includes a method for thermal performance characterization and system performance prediction of small custom built systems by means of component testing and system simulation.
Furthermore, this document contains methods for thermal performance characterization and system performance prediction of large custom built systems.
This document applies to the following types of small custom built solar heating systems:
- systems for domestic hot water preparation only;
- systems for space heating only;
- systems for domestic hot water preparation and space heating;
- others (e.g. including cooling).
This document applies to large custom built solar heating systems, primarily to solar preheat systems, with one or more storage vessels, heat exchangers, piping and automatic controls and with collector array(s) with forced circulation of fluid in the collector loop.
This document does not apply to
- systems with a store medium other than water (e.g. phase- change materials),
- thermosiphon systems,
- integral collector-storage (ICS) systems.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in EN 12977-1.
Stores tested according to this document are commonly used in solar hot water systems. However, the thermal performance of all other thermal stores with water as a storage medium can also be assessed according to the test methods specified in this document.
The document applies to stores with a nominal volume between 50 l and 3 000 l.
This document does not apply to combistores. Performance test methods for solar combistores are specified in EN 12977-4.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in EN 12977-1.
Stores tested according to this document are commonly used in solar combisystems. However, the thermal performance of all other thermal stores with water as a storage medium (e.g. for heat pump systems) can be also assessed according to the test methods specified in this document.
This document applies to combistores with a nominal volume up to 3 000 l and without integrated burner.
NOTE   This document is extensively based on references to EN 12977-3:2012.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of prEN 14511 1 is applicable, with the exception of process chillers.
1.2   This European Standard specifies minimum operating requirements which ensure that air conditioners, heat pumps and liquid chilling packages using either air, water or brine as heat transfer media, with electrical driven compressors are fit for the use designated by the manufacturer when used for space heating and/or cooling.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of prEN 14511 1 is applicable.
1.2   This European Standard specifies the test conditions for the rating of air conditioners, liquid chilling packages and heat pumps, using either, air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and/or cooling. The standard also specifies the test conditions for the rating of air-cooled and water-cooled process chillers.
1.3   This European Standard specifies the conditions for which performance data shall be declared for single duct and double duct units for compliance to the ecodesign Regulation 206/2012 and Energy Labelling Regulation 626/2011.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the terms and definitions for the rating and performance of air conditioners, liquid chilling packages and heat pumps using either, air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and/or cooling.
It also specifies the terms and definitions for the rating and performance of process chillers.
This European Standard does not apply to heat pumps for domestic hot water, although certain definitions can be applied to these.
This European Standard applies to:
-   factory-made units that can be ducted,
-   factory-made liquid chilling packages with integral condensers or for use with remote condensers,
-   factory-made units of either fixed capacity or variable capacity by any means, and
-   air-to-air air conditioners which can also evaporate the condensate on the condenser side.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, this European Standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This European Standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
The units having their condenser cooled by air and by the evaporation of external additional water should have their performance in the cooling mode determined in accordance to EN 15218. For those which can also operate in the heating mode, the EN 14511 series applies for the determination of their performance in the heating mode.
NOTE 1   Part load testing of units is dealt with in EN 14825.
NOTE 2   All the symbols given in this text are used regardless of the language.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in EN 12977-1.
Stores tested according to this document are commonly used in solar combisystems. However, the thermal performance of all other thermal stores with water as a storage medium (e.g. for heat pump systems) can be also assessed according to the test methods specified in this document.
This document applies to combistores with a nominal volume up to 3 000 l and without integrated burner.
NOTE   This document is extensively based on references to EN 12977-3:2012.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of prEN 14511 1 is applicable.
1.2   This European Standard specifies the test methods for the rating and performance of air conditioners, liquid chilling packages and heat pumps using either air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and cooling. These test methods also apply for the rating and performance of process chillers.
It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.
This European Standard also makes possible to rate multisplit and modular heat recovery multisplit systems by rating separately the indoor and outdoor units.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements on durability, reliability and safety of small and large custom built solar heating and cooling systems with liquid heat transfer medium in the collector loop for residential buildings and similar applications.
This document also contains requirements on the design process of large custom built systems.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to small and large custom built solar heating systems with liquid heat transfer medium for residential buildings and similar applications, and gives test methods for verification of the requirements specified in EN 12977-1.
This document also includes a method for thermal performance characterization and system performance prediction of small custom built systems by means of component testing and system simulation.
Furthermore, this document contains methods for thermal performance characterization and system performance prediction of large custom built systems.
This document applies to the following types of small custom built solar heating systems:
- systems for domestic hot water preparation only;
- systems for space heating only;
- systems for domestic hot water preparation and space heating;
- others (e.g. including cooling).
This document applies to large custom built solar heating systems, primarily to solar preheat systems, with one or more storage vessels, heat exchangers, piping and automatic controls and with collector array(s) with forced circulation of fluid in the collector loop.
This document does not apply to
- systems with a store medium other than water (e.g. phase- change materials),
- thermosiphon systems,
- integral collector-storage (ICS) systems.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies test methods for the performance characterization of stores which are intended for use in small custom built systems as specified in EN 12977-1.
Stores tested according to this document are commonly used in solar hot water systems. However, the thermal performance of all other thermal stores with water as a storage medium can also be assessed according to the test methods specified in this document.
The document applies to stores with a nominal volume between 50 l and 3 000 l.
This document does not apply to combistores. Performance test methods for solar combistores are specified in EN 12977-4.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies performance test methods for control equipment. Furthermore, this document contains requirements on accuracy, durability and reliability of control equipment.
The tests described in this document are limited to electrically activated components delivered with or for the system by the final supplier. For the purposes of this document controller and control equipment for solar heating systems and auxiliary heaters, if part of the system, are restricted to the following:
a)   Controllers as:
1)   system clocks, timers and counters;
2)   differential thermostats;
3)   multi-function controllers.
b)   Sensors as:
1)   temperature sensors;
2)   irradiance sensors (for short wave radiation);
3)   pressure sensors;
4)   level sensors;
5)   flow meters;
6)   heat meters.
c)   Actuators as:
1)   pumps;
2)   solenoid and motor valves;
3)   relays.
d)   Combinations of controllers, sensors and actuators listed above.
An additional objective of the procedures described in this document is to verify control algorithms and, together with the accuracy of sensors, to determine control parameters. In addition to verifying the functioning of a controller, its equipment and actuators, the determined parameters may be used for numerical system simulations.
Typically, electrical anodes are not part of the control equipment and are not controlled by the control equipment. However, because they are electrical appliances, electrical anodes are included in this document.
This document is valid for control equipment of solar heating systems for the purpose of hot water preparation and/or space heating. If the solar system is connected to or part of a conventional heating system, the validity is extended to the entire system. In combination with the standards EN 12976-1, EN 12976-2 as well as EN 12977-1, EN 12977-2, EN 12977-3 and EN 12977-4, this document is valid for
e) factory made solar heating systems,
f) small custom built solar heating systems,
g) large custom built solar heating systems,
h)   auxiliary heater equipment used in connection with e), f) and g).

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of EN 14511 1 is applicable.
1.2   This European Standard specifies the test conditions for the rating of air conditioners, liquid chilling packages and heat pumps, using either, air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and/or cooling. The standard also specifies the test conditions for the rating of air-cooled and water(brine)-cooled process chillers.
1.3   This European Standard specifies the conditions for which performance data is to be declared for single duct and double duct units for compliance to the Ecodesign Regulation 206/2012 and Energy Labelling Regulation 626/2011.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the terms and definitions for the rating and performance of air conditioners, liquid chilling packages and heat pumps using either air, water or brine as heat transfer media, with electrically driven compressors when used for space heating and/or cooling.
It also specifies the terms and definitions for the rating and performance of process chillers.
This European Standard does not apply to heat pumps for domestic hot water, although certain definitions can be applied to these.
This European Standard applies to:
-   factory-made units that can be ducted,
-   factory-made liquid chilling packages with integral condensers or for use with remote condensers,
-   factory-made units of either fixed capacity or variable capacity by any means, and
-   air-to-air air conditioners which can also evaporate the condensate on the condenser side.
Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard.
In the case of units consisting of several parts, this European Standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser.
This European Standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.
The units having their condenser cooled by air and by the evaporation of external additional water should have their performance in the cooling mode determined in accordance to EN 15218. For those which can also operate in the heating mode, the EN 14511 series applies for the determination of their performance in the heating mode.
NOTE 1   Part load testing of units is dealt with in EN 14825.
NOTE 2   All the symbols given in this text are used regardless of the language.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Es gilt der Anwendungsbereich von EN 14511-1.
1.2   Diese Europäische Norm legt die Prüfverfahren für die Bemessung und Leistung von Luftkondi-tionierern, Flüssigkeitskühlsätzen und Wärmepumpen, die Luft, Wasser oder Sole als Wärmeträger nutzen und mit elektrisch angetriebenen Verdichtern betrieben werden, für die Raumbeheizung und -kühlung fest. Diese Prüfverfahren gelten auch für die Bemessung und Leistung von Prozess-Kühlern.
Sie legt weiterhin ein Verfahren zur Prüfung und Angabe von Wärmerückgewinnungsleistungen, systemreduzierten Leistungen sowie der Leistung von Einzelgeräten von Multi-Split-Systemen für die Aufstellung im Innenraum, soweit zutreffend, fest.
Diese Europäische Norm bietet außerdem die Möglichkeit, die Leistung von Multi-Split-Systemen und modularen Multi-Split-Systemen mit Wärmerückgewinnung durch getrennte Leistungsbemessung von Geräten für die Aufstellung im Innenraum und Geräten für die Außenaufstellung (Innen- und Außengeräte) zu bemessen.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   The scope of EN 14511 1 is applicable, with the exception of process chillers.
1.2   This European Standard specifies minimum operating requirements which ensure that air conditioners, heat pumps and liquid chilling packages using either air, water or brine as heat transfer media, with electrical driven compressors are fit for the use designated by the manufacturer when used for space heating and/or cooling.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies only to condensing units for refrigeration and describes a number of selected performance test methods. These methods provide sufficiently accurate results for the determination of the refrigerating capacity, power absorbed, refrigerant mass flow and the coefficient of performance.
This European Standard applies only to performance tests conducted at the manufacturer's works or wherever the instrumentation and load stability for testing to the accuracy required is available.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard establishes requirements for determining, in accordance with a standardized procedure, the sound power level emitted into the surrounding air by air conditioners, heat pumps, liquid chilling packages with electrically driven compressors when used for space heating and/or cooling, including water cooled multisplit systems, as described in the prEN 14511 series and dehumidifiers as described in EN 810.
This draft European Standard also covers the measurement of the sound power level of evaporatively cooled condenser air conditioners, as defined in EN 15218. However, the measurement should be done without external water feeding and these units will thus be considered as the other air conditioners covered by the prEN 14511 series.
It is emphasized that this measurement standard only refers to airborne noise.
This draft European Standard offers ways to determine the sound power level of units. Some of them are specifically adapted to provide results with low uncertainties, by using laboratory class acoustic methods and highly controlled working conditions. Those measurements are suitable for certification, labelling and marking purposes.
In some cases, the target and/or the environment of the measurements do not allow such precision-class methods. This draft European Standard also offers ways to assess sound power levels with acceptable accuracy even though acoustic methods and/or working conditions are not laboratory-type, e.g. in situ or quality control measurements.
This draft European Standard gives two classes of measurements and results according to the test environment:
-   Class A measurements correspond to controlled working conditions (standard or application rating conditions). It is defined by the respect to the tolerances of Table 2 and should be used for the conformity to requirements of the Commission Regulation (EC) No 206/2012 of 6 March 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for air conditioners;
-   Class B measurements correspond to the case where the range defined by the tolerances of Table 2 cannot be fulfilled.
In both classes, precision or engineering class acoustic methods need to be applied. The choice of the acoustic measurement method is done in accordance with EN ISO 3740 and the EN ISO 9614 series depending on the type of surrounding acoustic fields (diffuse or free field, enclosed or open space), and the available instrumentation. Whatever the current working conditions, the reference of acoustic standard needs to be reported, with explicit mention of its accuracy class.
The use of EN ISO 3746 and EN ISO 3747 as survey grade methods are not recommended due to the high level of uncertainties. Their use is only allowed for non-controlled environments.
Three methods for determining the sound power levels are specified in order to avoid unduly restricting existing facilities and experience:
-   the first methodology is based on reverberation room measurement (see EN ISO 3741 and the EN ISO 3743 series);
-   the second method is based on measurements in an essentially free field over a reflecting plane (see EN ISO 3744 and EN ISO 3745);
-   the third method is based on sound intensity measurement (see the EN ISO 9614 series) in preferably free field environment.
The references in this draft European Standard to the EN ISO 3743 series should be understood as EN ISO 3743-1 or EN ISO 3743-2 as well.
The necessity to regulate the test conditions obviously leads to recommend test methods implemented in acoustically designed (enclosed) spaces, such as EN ISO 3741, the EN ISO 3743 series, EN ISO 3745 and also the EN ISO 9614 series when implemented in an enclosed space.
The open spaces should be covered only in specific cases, e.g. when the size or the power of the unit under test cannot be managed by standard test rooms. Suitable test methods are EN ISO 3744 and the EN ISO 9614 series.
(...)

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of prEN 16905
This European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as “GEHP appliance”.
This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.
This European Standard only applies to appliances having:
-   gas fired endothermic engines under the control of fully automatic control systems;
-   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
-   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
-   where the maximum operating pressure in the
-   heating water circuit (if installed) does not exceed 6 bar
-   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard.
The above appliances can have one or more primary or secondary functions.
This European Standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
In the case of packaged units (consisting of several parts), this European Standard applies only to those designed and supplied as a complete package.
NOTE   All the symbols given in this text are used regardless of the language used.
1.2   Scope of prEN 16905-1
This part of prEN 16905 specifies the terms and definitions of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of prEN 16905
This European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as “GEHP appliance”.
This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.
This European Standard only applies to appliances having:
-   gas fired endothermic engines under the control of fully automatic control systems;
-   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
-   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
-   where the maximum operating pressure in the
-   heating water circuit (if installed) does not exceed 6 bar
-   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard.
The above appliances can have one or more primary or secondary functions.
This European Standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
In the case of packaged units (consisting of several parts), this European Standard applies only to those designed and supplied as a complete package.
NOTE   All the symbols given in this text are used regardless of the language used.
1.2   Scope of prEN 16905-5
This part of prEN 16905 specifies the calculation of seasonal performance factor for heating and/or cooling mode including the engine heat recovery.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of prEN 16905
This European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as “GEHP appliance”.
This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.
This European Standard only applies to appliances having:
-   gas fired endothermic engines under the control of fully automatic control systems;
-   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
-   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
-   where the maximum operating pressure in the
-   heating water circuit (if installed) does not exceed 6 bar;
-   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard.
The above appliances can have one or more primary or secondary functions.
This European Standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
In the case of packaged units (consisting of several parts), the standard applies only to those designed and supplied as a complete package.
NOTE   All the symbols given in this text are used regardless of the language used.
1.2   Scope of prEN 16905-3
This part of prEN 16905 specifies the test conditions for the rating of energy parameters of gas-fired endothermic engine appliances for heating and/or cooling mode including the engine heat recovery.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of prEN 16905
This European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as “GEHP appliance”.
This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.
This European Standard only applies to appliances having:
-   gas fired endothermic engines under the control of fully automatic control systems;
-   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
-   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
-   where the maximum operating pressure in the
-   heating water circuit (if installed) does not exceed 6 bar;
-   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard.
The above appliances can have one or more primary or secondary functions.
This European Standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
In the case of packaged units (consisting of several parts), this European Standard applies only to those designed and supplied as a complete package.
NOTE   All the symbols given in this text are used regardless of the language used.
1.2   Scope of prEN 16905 4
This part of prEN 16905 specifies the test methods for gas engine driven heat pumps for gas-fired endothermic engine appliances heating and/or cooling mode including the engine. heat recovery.

  • Standard
    95 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The test code applies to the determination of the perfomances of  heating boilers combi boilers and water heaters fired by liquid fuels. The requirements are laid down in EN 303-1 and EN 303-2.
This code includesthe requirements and recommendations for carrying out and evaluating the procedure for testing boilers and also the details of the technical conditions under which the tests shall be carried out.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day