This European Standard applies to electric instantaneous water heaters for domestic hot water heating for household and similar applications, which show both of the following characteristics:
–   fulfilling at least one load pattern from Annex A;
–   heating up to temperatures below the boiling temperature.
This European Standard specifies terms, definitions and measurement methods for the assessment of energy efficiency.
This European Standard does not take into account requirements regarding t...
view more

    • sale 10% off
    • Amendment
      5 pages
      English language
    • e-Library read for
      1 day

This clause of part 1 is applicable except as follows.
Addition:
This standard applies to open outlet, single point of use, electric instantaneous water heaters intended for household or similar use, for showering purposes without downstream mixing.
This standard only specifies tests for the assessment of energy efficiency.
This standard does not apply to electrical instantaneous water heaters covered by other parts of this series of standards.

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies methods for measuring the performance of electric storage water heaters for the production of sanitary hot water for household and similar use.  
The object is to state and define the principal performance characteristics of electric storage water heaters and to describe the test methods for measuring these characteristics.
NOTE 1 This standard does not apply to;
   storage water heaters that use electricity as a secondary source of heating the water;
   stor...
view more

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

This clause of Part 1 is applicable with the following exception:
This European Standard applies to electrical instantaneous water heaters designed to operate as multifunctional appliances with electric rated power >2 kW.
This European Standard specifies tests for the assessment of the performance.

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

EN 12897:2016+A1 specifies the constructional and performance requirements and methods of test for indirectly heated, unvented (closed) storage water heaters of up to 2 000 l volume suitable for connection to a water supply at a pressure between 0,05 MPa and 1,0 MPa (0,5 bar and 10 bar), and fitted with control and safety devices designed to prevent the temperature of the stored drinking water from reaching 95 °C. Whilst storage water heaters intended primarily for direct heating are not covered...view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

EN 12897:2016+A1 specifies the constructional and performance requirements and methods of test for indirectly heated, unvented (closed) storage water heaters of up to 2 000 l volume suitable for connection to a water supply at a pressure between 0,05 MPa and 1,0 MPa (0,5 bar and 10 bar), and fitted with control and safety devices designed to prevent the temperature of the stored drinking water from reaching 95 °C. Whilst storage water heaters intended primarily for direct heating are not covered...view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

NEXT ACTION: UNDER BT CONSULTATION, CLOSING ON 2019-09-03
HAS CONSULTANT ASSESSMENT BY 2019-05-21
2019-04-16 CV:  Assessment for MD requested on 2019-04-16 (dd: 2019-05-21). If positively assessed, finalization will be brought to BT
2019-03-19 CV: Positively assessed by LVD Consultant and finalization of project brought to BT but consultation failed (Members want to have the project linked to the MD as well)
2019-01-23 CV: Revised Annex ZZ positively assessed and to be circulated to ...
view more

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements and test methods for surveillance systems for directly buried hot water networks in accordance with prEN 13941-1.
This document specifies requirements for the manufacture of measuring elements, for the manufacture of factory made bonded pipe, fitting and valve assemblies with measuring elements as well as for the assembly of the measuring elements in the field.
All requirements and recommendations described in this document are based on the experience gaine...
view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      27 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and test methods for joints between adjacent factory made pipe, and/or fitting and/or valve assemblies for buried hot water networks in accordance with EN 13941-1.

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      25 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a method for energy assessment of un-vented (closed) hot water storage tanks with a capacity up to 1 500 l, intended to be equipped with an external heat source and used for domestic hot water production. Whilst storage water heaters intended primarily for direct heating are not covered by this European Standard, it does allow the provision of electric heating elements for auxiliary use.

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      15 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and test methods for straight lengths of factory made thermally insulated bonded single pipe assemblies for hot water networks in accordance with prEN 13941-1:2016, comprising a steel service pipe, rigid polyurethane foam insulation and a casing of polyethylene.
The pipe assembly may also include the following additional elements: measuring wires, spacers and diffusion barriers.

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      45 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements and test methods for factory made thermally insulated bonded valve assemblies for hot water networks in accordance with prEN 13941-1, comprising a steel valve, rigid polyurethane foam insulation and a casing of polyethylene.
The valve assembly may also include the following additional elements: measuring wires, spacers and diffusion barriers.

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      28 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements and test methods for factory made thermally insulated bonded fitting assemblies for hot water networks in accordance with prEN 13941-1, comprising a steel service fitting, rigid polyurethane foam insulation and a casing of polyethylene.
The fitting assembly may also include the following additional elements: measuring wires, spacers and diffusion barriers.
This document covers the following fitting assemblies: bend, tee, reducer, single use compensator and ...
view more

    • sale 10% off
    • Standard
      31 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      33 pages
      English language
    • e-Library read for
      1 day

This document specifies a method for the energy assessment of domestic/sanitary hot water storage tanks of up to 2 000 l.
Whilst this document does not cover water heaters intended primarily for direct heating, it does allow the provision of electric heating elements for auxiliary use.
Primary heating buffer tanks are not covered by this document. Heat losses of domestic hot water storage tanks integrated into combi boilers marketed as a single unit are not covered by this document.

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      15 pages
      English language
    • e-Library read for
      1 day

This European Standard is composed of two parts.
The first part supplements EN 303 1, EN 303 2, EN 303 4 and EN 304 hereafter called boiler standards. It specifies the supplementary requirements and tests for the construction, safety, rational use of energy, fitness for purpose, classification and marking related to the domestic hot water operation of oil fired water heaters and combination boilers.
The domestic hot water is produced on either the instantaneous or storage principle. The domest...
view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      48 pages
      English language
    • e-Library read for
      1 day

This document is composed of two parts.
The first part supplements EN 303-1, EN 303-2, EN 303-4 and EN 304, hereafter called boiler standards. It specifies the supplementary requirements and tests for the construction, safety, rational use of energy, fitness for purpose, classification and marking related to the domestic hot water operation of oil-fired water heaters and combination boilers.
The domestic hot water is produced on either the instantaneous or storage principle. The domestic hot w...
view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      48 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies methods for testing the sound power level for water heating energy efficiency of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production.
This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system.
NOTE 1   ...
view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

This document specifies methods for testing the sound power level of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production.
This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system.
NOTE 1   Testing procedures for simultaneous operati...
view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both
instantaneous and storage gas-fired appliances combined with electrical heat pump.
It applies to a package marketed as single unit or fully specified by a manufacturer that have:
- a gas heat input not exceeding 70 kW;
- a hot water storage capacity not exceeding 500 litres.
Standard EN 13203-1 sets out in qualitative and quantitative terms the performance in delivery of domestic
hot wat...
view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day

This European Standard is applicable to gas-fired appliances producing domestic hot water. It applies to both instantaneous and storage tank appliances; waters-heaters and combination boilers that have:
-   a heat input not exceeding 70 kW; and
-   a hot water storage tank capacity (if any) not exceeding 500 l.
In the case of combination boilers, with or without storage tank, domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
EN 13203-1 sets out in...
view more

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day