Windows and doors - Product standard, performance characteristics - Part 2: Internal pedestrian doorsets

This European Standard identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, which are applicable to internal pedestrian doorsets.
Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034.
This European Standard applies to doorsets intended to be used internally for construction works as:
-   intended use a) in escape routes;
-   intended use b) for specific uses with specific requirements;
-   intended use c) for communication only.
NOTE 1   These above intended uses can be combined, for example escape routes with specific requirements.
For internal pedestrian doorsets with resistance to fire and /or smoke control characteristics, this standard should only apply in conjunction with EN 16034.
Products covered by this European Standard are power operated hinged or manually operated internal pedestrian doorsets and screens with flush or panelled leaves, single or double leaf, which could be completed with:
-   related building hardware;
-   door closing devices;
-   integral fanlights;
-   adjacent parts that are contained within a single frame for inclusion in a single aperture.
NOTE 2   Manually operated doors with door closing devices are not considered to be power operated doors.
Products covered by this European Standard are not assessed for structural applications.
This European Standard does not apply to:
-   industrial, commercial and garage doors and gates according to EN 13241;
-   external pedestrian doorsets according to EN 14351-1;
-   door leaves placed on the market as a single unit;
-   door frames placed on the market as a single unit;
-   power operated pedestrian doorsets, other than swing type, according to EN 16361.
Doorsets can be placed on the market with their component (leaf and frame) separate when each of these components are clearly identified.
This European Standard does not deal with any specific requirements on noise emitted from internal power operated hinged doorsets as their noise emission is not considered to be a relevant hazard.

Fenster und Türen - Produktnorm, Leistungseigenschaften - Teil 2: Innentüren

Die vorliegende Europäische Norm identifiziert werkstoffunabhängige Leistungsmerkmale, außer Feuerbeständigkeits- und Rauchdichtheitseigenschaften, die für Innentüren gelten.
Feuerbeständigkeits- und/oder Rauchdichtheitseigenschaften für Türen und Fenster werden von EN 16034 abgedeckt.
Diese Europäische Norm gilt für Innentüren in Bauwerken, die für folgende Zwecke verwendet werden:
-   Verwendungszweck a) in Fluchtwegen;
-   Verwendungszweck b) für besondere Verwendungszwecke mit besonderen Anforderungen;
-   Verwendungdzweck c) lediglich als Verbindung.
ANMERKUNG 1   Die oben genannten Anwendungsgebiete können kombiniert werden, z. B. Fluchtwege mit besonderen Anforderungen.
Für Innentüren mit Feuerbeständigkeits- und/oder Rauchdichtheitseigenschaften sollte diese Norm nur in Verbindung mit EN 16034 angewendet werden.
Produkte, die durch diese Europäische Norm abgedeckt werden, sind kraftbetätigte Drehflügeltüren oder handbetätigte Innentüren und Vorsatztüren mit Sperr- oder Füllungstürblättern, ein- oder zweiflügelig, die ergänzt werden könnten mit:
-   zugehörigen Baubeschlägen;
-   Türschließmitteln;
-   integrierten Oberlichtern;
-   angrenzenden Seiten- und Oberteilen, in einem einzigen (gemeinsamen) Rahmen zum Einbau in eine gemeinsame Öffnung.
ANMERKUNG 2   Handbetätigte Türen mit Türschließmitteln werden nicht als kraftbetätigten Türen angesehen
Die in dieser Europäischen Norm beschriebenen Produkte weren nicht für eine Anwendung als tragende Bauteile bewertet.
Diese Europäische Norm gilt nicht für:
-   Tore nach EN 13241;
-   Außentüren nach EN 14351-1;
-   im Handel einzeln erhältliche Türflügel;
-   im Handel einzeln erhältliche Türrahmen;
-   kraftbetätigte Türen nach EN 16361, die keine Drehflügeltüren sind.
Türen können einzeln mit ihren Komponenten (Flügel und Rahmen) auf dem Markt angeboten werden, wenn jede dieser Komponenten eindeutig identifiziert wurde.
Die vorliegende Europäische Norm beschäftigt sich nicht mit spezifischen Anforderungen bezüglich Lärm von kraftbetätigten Drehflügelinnentüren, da Lärmemissionen nicht als relevante Gefährdung angesehen werden.

Portes et fenêtres - Norme produit, caractéristiques de performances - Partie 2: Blocs-portes intérieurs pour piétons

La présente Norme européenne identifie des caractéristiques de performance indépendantes des matériaux, à l'exception des caractéristiques de résistance au feu et de contrôle de la fumée, qui s'appliquent aux blocs-portes intérieurs pour piétons.
Les caractéristiques de résistance au feu et / ou de contrôle de la fumée pour les portes de garage et les fenêtres ouvrantes sont couvertes par la norme EN 16034.
Cette norme européenne s'applique aux blocs-portes destinés à être utilisés à l'intérieur des ouvrages de construction :
- usage prévu a) pour les issues de secours non soumis à des réglementations concernant la résistance au feu et/ou le dégagement de fumée ;
- usage prévu b) pour des usages spécifiques associés à des exigences particulières ;
- usage prévu c) pour la communication uniquement.
NOTE 1 Les usages prévus indiqués ci-dessus peuvent être combinés, par exemple issues de secours associées à des exigences particulières.
Pour les blocs-portes intérieurs pour piétons avec résistance au feu et/ou aux caractéristiques de contrôle de fumée, cette norme ne doit s'appliquer qu'avec EN 16034.
Les produits couverts par la présente Norme européenne sont des blocs-portes battants intérieurs manuels ou motorisés pour piétons et ensembles composés avec vantaux plans ou menuisés, à un ou deux vantaux, pouvant être complétés :
- de la quincaillerie associée ;
- de dispositifs de fermeture de porte ;
- d'impostes ;
- de parties adjacentes qui sont intégrées dans un châssis individuel afin d'être installées dans une seule ouverture.
NOTE 2 Les portes manuelles avec dispositifs de fermeture de porte ne sont pas des portes motorisées.
Les produits couverts par la présente Norme européenne ne sont pas destinés à des applications structurelles.
La présente Norme européenne ne s’applique pas aux :
- portes industrielles, commerciales et de garages qui relèvent de l’EN 13241 ;
- blocs-portes extérieurs pour piétons qui relèvent de l'EN 14351-1 ;
- vantaux de portes commercialisés à l’unité ;
- dormants commercialisés à l’unité ;
- blocs-portes motorisés pour piétons, autre que le type battant, qui relèvent de l'EN 16361.
Des ensembles de portes peuvent être mis sur le marché avec leur composant (ouvrant et dormant) séparés lorsque chacun de ces composants sont clairement identifiés.
La présente Norme européenne ne traite pas d'exigences particulières concernant le bruit émis par les portes battantes intérieures motorisées car l'émission sonore n'est pas considérée comme un danger pertinent.

Okna in vrata - Standard za proizvod, zahtevane lastnosti - 2. del: Notranja vrata

Ta evropski standard določa zahtevane lastnosti, ki niso odvisne od materialov in se uporabljajo za notranja vrata brez odpornosti proti požaru in/ali uhajanju dima.
Ta dokument se uporablja za vrata, ki so namenjena notranji uporabi pri gradbenih objektih:
– pri evakuacijskih poteh, ki niso podvržene požaru in/ali uhajanju dima;
– za posebne uporabe z posebnimi zahtevami;
– samo za komunikacijo.
OPOMBA: Te zgoraj predvidene uporabe je mogoče kombinirati, na primer evakuacijske poti s posebnimi zahtevami.
Izdelki, ki so zajeti v tem evropskem standardu, so električno ali ročno upravljana notranja vrata in rešetke z enoslojnimi ali dvoslojnimi gladkimi ali panelnimi krili, ki jih je mogoče dokončati s/z:
– ustreznim stavbnim okovjem;
– napravami za zapiranje vrat.
OPOMBA: Ročno upravljana vrata z napravami za zapiranje vrat niso električno upravljana vrata.
– pahljačastimi okenci nad vrati;
– soležnimi deli, ki so sestavni del enega okvirja za vključitev v eno odprtino.
Izdelki, ki so zajeti v tem evropskem standardu, niso ocenjeni za konstrukcijsko uporabo.
Ta evropski standard se ne uporablja za:
– vrata za industrijske in javne prostore ter garažna vrata v skladu s standardom EN 13241-1;
– zunanje sestave vrat za prehod ljudi v skladu s standardom EN 14351-1;
– vratna krila, ki so dana na trg ločeno;
– vratni okvirji, ki so dani na trg ločeno;
– električno upravljana zunanja vrata v skladu s standardom EN 16361.
Emisije hrupa električno upravljanih notranjih krilnih vrat se ne obravnavajo kot ustrezno tveganje; zaradi tega ta standard ne vsebuje nobenih posebnih zahtev glede hrupa.

General Information

Status
Published
Publication Date
06-Nov-2018
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Due Date
07-Nov-2018
Completion Date
07-Nov-2018

Buy Standard

Standard
EN 14351-2:2019
English language
53 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Okna in vrata - Standard za proizvod, zahtevane lastnosti - 2. del: Notranja vrataFenster und Türen - Produktnorm, Leistungseigenschaften - Teil 2: InnentürenPortes et fenêtres - Norme produit, caractéristiques de performances - Partie 2: Blocs-portes intérieurs pour piétonsWindows and doors - Product standard, performance characteristics - Part 2: Internal pedestrian doorsets91.060.50Vrata in oknaDoors and windowsICS:Ta slovenski standard je istoveten z:EN 14351-2:2018SIST EN 14351-2:2019en,fr,de01-januar-2019SIST EN 14351-2:2019SLOVENSKI

STANDARD
SIST EN 14351-2:2019
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14351-2
November
t r s z ICS
{ sä r x rä w r English Version
Windows and doors æ Product standardá performance characteristics æ Part

tã Internal pedestrian doorsets Portes et fenêtres æ Norme produitá caractéristiques de performances æ Partie

tã Blocsæportes intérieurs pour piétons
Fenster und Türen æ Produktnormá Leistungseigenschaften æ Teil
tã Innentüren This European Standard was approved by CEN on
u April
t r s zä

egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä

translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä

CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä

EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre:
Rue de la Science 23,
B-1040 Brussels

t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN

s v u w sæ tã t r s z ESIST EN 14351-2:2019

EN 14351-2:2018 (E) 2 Contents Page European foreword ............................................................................................................................................. 5 1 Scope .......................................................................................................................................................... 7 2 Normative references .......................................................................................................................... 8 3 Terms, definitions and symbols .....................................................................................................10 3.1 Terms and definitions .......................................................................................................................10 3.2 Symbols ...................................................................................................................................................11 4 Product characteristics .....................................................................................................................12 4.1 General ....................................................................................................................................................12 4.2 Release of dangerous substances (only for emissions into indoor air impact) (for intended use a, b and c) ....................................................................................................................12 4.3 Impact resistance (where relevant, only for glazed doors with injury risks) (for intended use a, b and c) ....................................................................................................................12 4.3.1 Glazed doors..........................................................................................................................................12 4.3.2 Unframed glass doorsets ..................................................................................................................12 4.4 Height (for intended use a, b and c) ..............................................................................................12 4.5 Reaction to fire .....................................................................................................................................12 4.5.1 Reaction to fire of components (for intended use a, b and c)..............................................12 4.5.2 Reaction to fire of the doorset ........................................................................................................13 4.6 Direct airborne sound insulation index (only for uses where acoustic performance is required) (for intended use b) .......................................................................................................13 4.7 Operating forces (only for automatic devices and only for internal landing communication doors and doors for special uses and specific requirements) (for intended use b) ....................................................................................................................................14 4.8 Thermal transmittance (only for uses where thermal insulation performance is required) (for intended use b) .......................................................................................................14 4.9 Air permeability (only for uses where air permeability performance is required for specific use with specific requirements) (for intended use b) ...........................................14 4.10 Ability to release (to open) (only for locked doors in escape routes) (for intended use a) ........................................................................................................................................................14 4.11 Durability ...............................................................................................................................................14 4.11.1 Durability of air permeability against ageing/degradation for specific use with specific requirements (for intended use b): ..............................................................................14 4.11.2 Durability of operating forces (safety in use) against ageing/degradation (only for automatic devices and only for internal landing communication doors and doors for special uses with specific requirements) (for intended use b) ..........................................14 4.12 Width .......................................................................................................................................................15 4.13 Manual operating forces ...................................................................................................................15 4.14 Mechanical strength ...........................................................................................................................15 4.15 Bullet resistance ..................................................................................................................................15 4.16 Explosion resistance ..........................................................................................................................15 4.17 Resistance to repeated opening and closing .............................................................................15 4.18 Behaviour between two different climates ...............................................................................15 4.19 Burglar resistance ...............................................................................................................................15 4.20 Safety requirements for power operated pedestrian hinged doorsets ...........................16 4.21 Ventilation .............................................................................................................................................16 SIST EN 14351-2:2019

EN 14351-2:2018 (E) 3 5 Testing, assessment and sampling methods ............................................................................. 16 5.1 General ................................................................................................................................................... 16 5.2 Dangerous substances .................................................................... Error! Bookmark not defined. 5.3 Impact resistance (only for glazed doors with injury risk) (for intended use a, b and c) ............................................................................................................. Error! Bookmark not defined. 5.4 Height (for intended use a, b and c) ............................................................................................. 16 5.5 Reaction to fire .................................................................................................................................... 17 5.6 Direct airborne sound insulation index (only for uses where acoustic performance is required) (for intended use b) ....................................................................................................... 17 5.6.1 Reference method .............................................................................................................................. 17 5.6.2 Alternative method ............................................................................................................................ 17 5.7 Operating forces (only for automatic devices and only for internal landing communication doors and doors for special uses) (for intended use b) ........................ 17 5.8 Thermal transmittance (only for uses where thermal insulation performance is required) (for intended use b) ....................................................................................................... 17 5.8.1 Reference method .............................................................................................................................. 17 5.8.2 Tabulation ............................................................................................................................................. 18 5.8.3 Calculation ............................................................................................................................................ 18 5.9 Air permeability (only for uses where air permeability performance is required for specific use with specific requirements) (for intended use b)........................................... 18 5.10 Ability to release (to open) (only for locked doors in escape routes) (for intended use a) ....................................................................................................................................................... 18 5.11 Durability .............................................................................................................................................. 18 5.11.1 Durability of air permeability against ageing/degradation (for intended use b)....... 18 5.11.2 Durability of operating forces (only for automatic devices, and only for internal landing communication doors and doors for special uses with specific requirements) (for intended use b) ............................................................................................. 18 5.12 Width ....................................................................................................................................................... 19 5.13 Manual operating forces .................................................................................................................. 19 5.14 Mechanical strength .......................................................................................................................... 19 5.15 Bullet resistance ................................................................................................................................. 19 5.16 Explosion resistance .......................................................................................................................... 19 5.17 Resistance to repeated opening and closing............................................................................. 19 5.18 Behaviour between two different climates ............................................................................... 19 5.19 Burglar resistance .............................................................................................................................. 19 5.20 Safety requirements for power operated pedestrian hinged doorsets .......................... 19 5.21 Ventilation ............................................................................................................................................. 20 6 Assessment and verification of constancy of performance – AVCP .................................. 20 6.1 General ................................................................................................................................................... 20 6.2 Type testing .......................................................................................................................................... 20 6.2.1 General ................................................................................................................................................... 20 6.2.2 Test samples, testing and compliance criteria ......................................................................... 21 6.2.3 Test reports .......................................................................................................................................... 21 6.2.4 Shared other party results .............................................................................................................. 21 6.2.5 Cascading determination of the product type results ........................................................... 22 6.3 Factory production control (FPC) ................................................................................................. 23 6.3.1 General ................................................................................................................................................... 23 6.3.2 Requirements ....................................................................................................................................... 24 6.3.3 Product specific requirements ...................................................................................................... 26 6.3.4 Initial inspection of factory and of FPC ....................................................................................... 26 6.3.5 Continuous surveillance of FPC (only for products covered by AVCP system 1) ......... 27 6.3.6 Procedure for modifications ........................................................................................................... 27 SIST EN 14351-2:2019

EN 14351-2:2018 (E) 4 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity ...........................................................................................................................27 7 Marking, Labelling and packaging ................................................................................................28 Annex A (informative)

Product characteristics possibly affected by change of components ...........................................................................................................................................30 A.1 General ....................................................................................................................................................30 Annex B (normative)

Tabulated values and extension of test results following size and design variations .................................................................................................................................32 B.1 Characteristics of internal pedestrian doorsets ......................................................................32 B.2 Sound insulation index of internal pedestrian doorsets ......................................................34 B.3 Thermal transmittance for Internal pedestrian doorsets UD in accordance to constructive details ............................................................................................................................35 Annex C (informative)

Example of performance and requirement profile of an Internal pedestrian doorsets ...........................................................................................................................36 Annex D (informative)

Examples for opening dimensions of internal pedestrian doorsets 37 Annex E (informative)

Handling, installation, maintenance and care ..........................................39 Annex F (normative)

Selection, preparation, mounting and fixing of test sample(s) for reaction to fire tests and field of direct application ...............................................................40 F.1 General ....................................................................................................................................................40 F.2 EN ISO 11925-2 (Single flame test) ...............................................................................................40 F.2.1 Profile ......................................................................................................................................................40 F.2.2 Infill or door leaf ..................................................................................................................................42 F.2.3 Sealant between infill and profile .................................................................................................42 F.2.4 Organic coating/top layers ..............................................................................................................43 F.3 Mounting and fixing for EN 13823 (SBI-test) ............................................................................44 F.3.1 Testing of the individual components .........................................................................................44 F.3.2 Testing of the doorset ........................................................................................................................45 F.4 EN ISO 1182 (Non-combustibility test) .......................................................................................46 F.5 EN ISO 1716 (Determination of the heat of combustion) .....................................................46 F.6 Field of direct application ................................................................................................................47 Annex ZA (informative)

Relationship of this European Standard with Regulation (EU) N°.305/2011 ..........................................................................................................................................48 ZA.1 Scope and relevant characteristics ...............................................................................................48 ZA.2 System of assessment and Verification of Constancy of Performance (AVCP) .............50 ZA.3 Assignment of AVCP tasks ................................................................................................................50 Bibliography ........................................................................................................................................................53

SIST EN 14351-2:2019

EN 14351-2:2018 (E) 5 European foreword This document (EN 14351-2:2018) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2019, and conflicting national standards shall be withdrawn at the latest by August 2021. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a standardisation request given to CEN by the European Commission and the European Free Trade Association, and supports Basic Work Requirements of EU Regulation and Essential Requirements of EU Directive(s). For relationship with EU Regulation/Directive(s), see informative Annex ZA, which is an integral part of this document. This European Standard is one of a series of standards for windows and pedestrian doorsets (see Figure 1). 1) EN 14351-2 alone, applies to all internal pedestrian doorsets. 2) For the internal pedestrian doorsets having fire resisting and/or smoke control characteristics, EN 16034 should apply in conjunction with EN 14351-2.

Figure 1 — Relationship between various standards SIST EN 14351-2:2019

EN 14351-2:2018 (E) 6 According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 14351-2:2019

EN 14351-2:2018 (E) 7 1 Scope This European Standard identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, which are applicable to internal pedestrian doorsets. Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034. This European Standard applies to doorsets intended to be used internally for construction works as: — intended use a) in escape routes; — intended use b) for specific uses with specific requirements; — intended use c) for communication only. NOTE 1 These above intended uses can be combined, for example escape routes with specific requirements. For internal pedestrian doorsets with resistance to fire and /or smoke control characteristics, this standard should only apply in conjunction with EN 16034. Products covered by this European Standard are power operated hinged or manually operated internal pedestrian doorsets and screens with flush or panelled leaves, single or double leaf, which could be completed with: — related building hardware; — door closing devices; — integral fanlights; — adjacent parts that are contained within a single frame for inclusion in a single aperture. NOTE 2 Manually operated doors with door closing devices are not considered to be power operated doors. Products covered by this European Standard are not assessed for structural applications. This European Standard does not apply to: — industrial, commercial and garage doors and gates according to EN 13241; — external pedestrian doorsets according to EN 14351-1; — door leaves placed on the market as a single unit; — door frames placed on the market as a single unit; — power operated pedestrian doorsets, other than swing type, according to EN 16361. Doorsets can be placed on the market with their component (leaf and frame) separate when each of these components are clearly identified. This European Standard does not deal with any specific requirements on noise emitted from internal power operated hinged doorsets as their noise emission is not considered to be a relevant hazard. SIST EN 14351-2:2019

EN 14351-2:2018 (E) 8 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 179, Building hardware — Emergency exit devices operated by a lever handle or push pad, for use on escape routes — Requirements and test methods EN 947, Hinged or pivoted doors — Determination of the resistance to vertical load EN 948, Hinged or pivoted doors — Determination of the resistance to static torsion EN 949, Windows and curtain walling, doors, blinds and shutters — Determination of the resistance to soft and heavy body impact for doors EN 950, Door leaves — Determination of the resistance to hard body impact EN 1026:2016, Windows and doors — Air permeability — Test method EN 1121, Doors - Behaviour between two different climates — Test method EN 1125, Building hardware — Panic exit devices operated by a horizontal bar, for use on escape routes — Requirements and test methods EN 1154, Building hardware — Controlled door closing devices — Requirements and test methods EN 1191, Windows and doors — Resistance to repeated opening and closing — Test method EN 1192, Doors — Classification of strength requirements EN 1522, Windows, doors, shutters and blinds — Bullet resistance — Requirements and classification EN 1523, Windows, doors, shutters and blinds — Bullet resistance — Test method EN 1627, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance — Requirements and classification EN 1628, Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading EN 1629, Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading EN 1630, Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts EN 1935, Building hardware — Single-axis hinges — Requirements and test methods EN 12046-2, Operating forces — Test method — Part 2: Doors EN 12150-2, Glass in building — Thermally toughened soda lime silicate safety glass — Part 2: Evaluation of conformity/Product standard EN 12207, Windows and doors — Air permeability — Classification SIST EN 14351-2:2019

EN 14351-2:2018 (E) 9 EN 12217:2015, Doors — Operating forces — Requirements and classification EN 12219, Doors — Climatic influences — Requirements and classification EN 12365-1:2003, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 1: Performance requirements and classification EN 12365-2, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 2: Linear compression force test methods EN 12365-3, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 3: Deflection recovery test method EN 12365-4, Building hardware — Gasket and weatherstripping for doors, windows, shutters and curtain walling — Part 4: Recovery after accelerated ageing test method EN 12400:2002, Windows and pedestrian doors — Mechanical durability — Requirements and classification EN 12519:2018, Windows and pedestrian doors — Terminology EN 12600:2002, Glass in building — Pendulum test — Impact test method and classification for flat glass EN 13049:2003, Windows — Soft and heavy body impact — Test method, safety requirements and classification EN 13123-1, Windows, doors and shutters — Explosion resistance — Requirements and classification — Part 1: Shock tube EN 13124-1, Windows, doors and shutters — Explosion resistance — Test method — Part 1: Shock tube EN 13141-1, Ventilation for buildings — Performance testing of components/products for residential ventilation — Part 1: Externally and internally mounted air transfer devices EN 13141-2, Ventilation for buildings — Performance testing of components/products for residential ventilation — Part 2: Exhaust and supply air terminal devices EN 13238, Reaction to fire tests for building products — Conditioning procedures and general rules for selection of substrates EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 13637:2015, Building hardware — Electrically controlled exit systems for use on escape routes — Requirements and test methods EN 14179-2, Glass in building — Heat soaked thermally toughened soda lime silicate safety glass — Part 2: Evaluation of conformity/Product standard EN 14351-1, Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets EN 14449, Glass in building — Laminated glass and laminated safety glass — Evaluation of conformity/Product standard SIST EN 14351-2:2019

EN 14351-2:2018 (E) 10 EN 16005:2012, Power operated pedestrian doorsets — Safety in use — Requirements and test methods EN 16034, Pedestrian doorsets, industrial, commercial, garage doors and openable windows — Product standard, performance characteristics — Fire resisting and/or smoke control characteristics EN ISO 717-1, Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation (ISO 717-1) EN ISO 10077-1:2006, Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General (ISO 10077-1:2017) EN ISO 10077-2, Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames (ISO 10077-2) EN ISO 10140-1, Acoustics — Laboratory measurement of so

...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.