EN 14318-2:2013
(Main)Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2: Specification for the installed insulation products
General Information
- Abstract
This European Standard specifies requirements for in-situ formed dispensed polyurethane foam (PUR) and polyisocyanurate (PIR) foam products when installed into cavity walls.
This Part 2 of this European Standard is a specification for the installed insulation product.
This Part 2 of this European Standard describes, when taken together with Part 1 of EN 14318, the product characteristics linked to the essential requirements of the EU Construction Products Directive. It also specifies the checks and tests to be used for the declarations made by the installer of the product.
This European Standard does not specify the required levels of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards.
This European Standard does not cover factory made rigid polyurethane (PUR) or polyisocyanurate (PIR) foam products or in-situ products intended to be used for the insulation of building equipment and industrial installations.
NOTE Foam products are either called flexible or rigid. The flexible products are used in upholstery and mattresses and are characterised by their ability to deflect, support and recover to their original thickness continually during their in-use phase. Those that are not flexible are termed rigid and do not possess these flexible characteristics. They are mostly used for thermal insulation purposes and vary widely in their compression strength values. Once the cell structure is crushed in a rigid foam, it does not recover its thickness fully. Some of these rigid foams are very low in density with very low compression strengths and are sometimes described “commercially” as “soft foams” or “semi-rigid” foams. This note has been included to clarify that all foams with such descriptions are covered by this standard’s used of the term rigid foam.
- Status
- Published
- Publication Date
- 15-Jan-2013
- Technical Committee
- CEN/TC 88 - Thermal insulating materials and products
- Drafting Committee
- CEN/TC 88/WG 15 - In situ formed insulation products
- Current Stage
- 9093 - Decision to confirm - Review Enquiry
- Start Date
- 07-Apr-2025
- Completion Date
- 17-Sep-2026
- Directive
- Harmonized Standard305/2011 - Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
Not Harmonized89/106/EEC - Construction products
Overview
EN 14318-2:2013 - “Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2” is the CEN specification for the installed insulation product used in cavity walls. It complements EN 14318-1 (the system specification before installation) and, together with Part 1, links product characteristics to the essential requirements of the EU Construction Products Directive. This Part 2 standard covers installation checks, measurements and the installer’s declarations needed to document compliance for in-situ dispensed PUR/PIR cavity wall insulation.
Key topics and requirements
- Scope: Applies to in-situ dispensed rigid PUR and PIR foams installed into building cavity walls. It does not cover factory-made boards or insulation for building equipment/industrial installations.
- System compliance: Installers must use a foam system that complies with EN 14318-1.
- Suitability check: Installer must inspect the building (see Annex B) and verify the cavity and site are suitable prior to application.
- Installed thickness (d): The declared installed insulation thickness - the average cavity width - is determined according to the procedure in Annex A (measurement through injection/drill holes). The installed thickness must not be less than the client’s or manufacturer’s minimum.
- Declared aged thermal resistance (RD): RD (time-average thermal resistance over 25 years) is declared using the manufacturer’s performance chart and procedures from EN 14318-1; corrections for moisture/temperature follow EN ISO 10456 where applicable.
- On-site quality checks: Installer carries out manufacturer-defined on-site foam quality checks and generates test samples per EN 14318-1 (and local rules). Annex C addresses water vapour passage control in insulated cavities.
- Installer’s declaration: Mandatory information to the customer includes installation date, declared installed thickness, declared RD, product trade name/designation, and EC certificate of conformity.
Practical applications
- Use for documenting, verifying and certifying cavity wall insulation projects using in-situ dispensed PUR/PIR foams.
- Useful for builders, insulation contractors, energy retrofit specialists, building inspectors and specifiers who need to ensure installed performance and regulatory compliance.
- Supports energy-efficiency retrofits and new-build cavity insulation where in-situ rigid foam is specified.
Who should use this standard
- Insulation installers and contractors (installation procedures, measurements, declarations)
- Product manufacturers (to link Part 1 product information with installed product requirements)
- Building certifiers, architects and regulators (to assess fitness for purpose and conformity)
- Facility managers and homeowners (for informed procurement and compliance documentation)
Related standards
- EN 14318-1:2013 (system specification before installation)
- EN ISO 9229 (vocabulary)
- EN ISO 10456 (moisture/temperature corrections)
- EN ISO 6946 (thermal resistance of building elements)
Keywords: EN 14318-2:2013, in-situ dispensed PUR, PIR foam, cavity wall insulation, installed insulation specification, declared RD, installer declaration, EN 14318-1.
Relations
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 09-Feb-2026
- Referred By
CLC/TR 62258-8:2008 - Semiconductor die products - Part 8: EXPRESS model schema for data exchange - Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
EN 14318-2:2013 is a standard published by the European Committee for Standardization (CEN). Its full title is "Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2: Specification for the installed insulation products". This standard covers: This European Standard specifies requirements for in-situ formed dispensed polyurethane foam (PUR) and polyisocyanurate (PIR) foam products when installed into cavity walls. This Part 2 of this European Standard is a specification for the installed insulation product. This Part 2 of this European Standard describes, when taken together with Part 1 of EN 14318, the product characteristics linked to the essential requirements of the EU Construction Products Directive. It also specifies the checks and tests to be used for the declarations made by the installer of the product. This European Standard does not specify the required levels of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards. This European Standard does not cover factory made rigid polyurethane (PUR) or polyisocyanurate (PIR) foam products or in-situ products intended to be used for the insulation of building equipment and industrial installations. NOTE Foam products are either called flexible or rigid. The flexible products are used in upholstery and mattresses and are characterised by their ability to deflect, support and recover to their original thickness continually during their in-use phase. Those that are not flexible are termed rigid and do not possess these flexible characteristics. They are mostly used for thermal insulation purposes and vary widely in their compression strength values. Once the cell structure is crushed in a rigid foam, it does not recover its thickness fully. Some of these rigid foams are very low in density with very low compression strengths and are sometimes described “commercially” as “soft foams” or “semi-rigid” foams. This note has been included to clarify that all foams with such descriptions are covered by this standard’s used of the term rigid foam.
This European Standard specifies requirements for in-situ formed dispensed polyurethane foam (PUR) and polyisocyanurate (PIR) foam products when installed into cavity walls. This Part 2 of this European Standard is a specification for the installed insulation product. This Part 2 of this European Standard describes, when taken together with Part 1 of EN 14318, the product characteristics linked to the essential requirements of the EU Construction Products Directive. It also specifies the checks and tests to be used for the declarations made by the installer of the product. This European Standard does not specify the required levels of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards. This European Standard does not cover factory made rigid polyurethane (PUR) or polyisocyanurate (PIR) foam products or in-situ products intended to be used for the insulation of building equipment and industrial installations. NOTE Foam products are either called flexible or rigid. The flexible products are used in upholstery and mattresses and are characterised by their ability to deflect, support and recover to their original thickness continually during their in-use phase. Those that are not flexible are termed rigid and do not possess these flexible characteristics. They are mostly used for thermal insulation purposes and vary widely in their compression strength values. Once the cell structure is crushed in a rigid foam, it does not recover its thickness fully. Some of these rigid foams are very low in density with very low compression strengths and are sometimes described “commercially” as “soft foams” or “semi-rigid” foams. This note has been included to clarify that all foams with such descriptions are covered by this standard’s used of the term rigid foam.
EN 14318-2:2013 is classified under the following ICS (International Classification for Standards) categories: 91.100.60 - Thermal and sound insulating materials. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 14318-2:2013 has the following relationships with other standards: It is inter standard links to EN ISO 9229:2007, EN 14318-1:2013, EN 62507-1:2011, CLC/TR 62258-8:2008, EN 61360-1:2017, EN 61360-2:2013, EN 62656-1:2015, EN ISO 16739-1:2020, EN 9300-004:2013, EN 16603-31-04:2019, EN ISO 12006-3:2016, EN 9300-007:2017, CR 13935:2000, EN ISO 23387:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 14318-2:2013 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/103. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 14318-2:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz trde poliuretanske pene (PUR) in poliizocianuratne pene (PIR), oblikovani na mestu vgradnje - 2. del: Specifikacija za vgrajene izolacijske proizvodeWärmedämmstoffe für das Bauwesen - An der Verwendungsstelle hergestellte Wärmedämmung aus dispensiertem Polyurethan (PUR)- und Polyisocyanurat (PIR)-Hartschaum - Teil 2: Spezifikation für die eingebauten ProdukteProduits isolant thermiques destinés aux applications du bâtiment - Produits en mousse rigide de polyuréthanne (PUR) ou de polyisocyanurate (PIR) injectée, formés en place - Partie 2: Spécifications relatives aux produits d'isolation après installationThermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2: Specification for the installed insulation products91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 14318-2:2013SIST EN 14318-2:2013en,fr,de01-julij-2013SIST EN 14318-2:2013SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14318-2
January 2013 ICS 91.100.60 English Version
Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2: Specification for the installed insulation products
Produits isolants thermiques destinés aux applications du bâtiment - Produits en mousse rigide de polyuréthanne (PUR) ou de polyisocyanurate (PIR) injectée, formés en place - Partie 2 : Spécifications relatives aux produits isolants après mise en oeuvre
Wärmedämmstoffe für das Bauwesen - An der Verwendungsstelle hergestellter Wärmedämmstoff aus dispensiertem Polyurethan(PUR)- und Polyisocyanurat(PIR)-Hartschaum - Teil 2: Spezifikation für die eingebauten Produkte This European Standard was approved by CEN on 17 November 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14318-2:2013: ESIST EN 14318-2:2013
Method for the determination of the declared installed insulation thickness: Average cavity width . 8 A.1 Procedure . 8 A.2 Calculation. 8 Annex B (normative)
Suitability of the building to receive the insulation product . 9 B.1 Building . 9 B.2 Site survey . 9 Annex C (normative)
Control of the passage of water vapour in insulated masonry cavities . 11 Annex D (normative)
Installation guidelines . 12 D.1 General . 12 D.2 Suitability of cavity . 12 D.3 Dispensing machine preparation . 12 D.3.1 Preparation . 12 D.3.2 Mixing ratio . 12 D.4 Dispensing procedure . 12 Bibliography. 13
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 9229:2007 and the following apply. 3.1.1
polyurethane foam PUR
(in-situ formed products) rigid cellular plastics insulation material or product with a structure based on polymers mainly of the polyur
...