Determination of the elasticity of fabrics - Part 2: Multiaxial tests

This European Standard specifies the methods of test, which can be used to measure elasticity and related properties of fabrics, when they undergo a deformation of their surface, excluding narrow fabrics.  Two methods are specified, one a dynamic method (method A) and the other a static method (method B).
The results obtained cannot be compared. The choice of method should be agreed between parties and indicated in the test report.

Bestimmung der Elastizität von textilen Flächengebilden - Teil 2: Multiaxiale Prüfungen

Diese Norm beschreibt die Prüfverfahren, die zur Messung der Elastizität und zugehöriger Eigenschaften von textilen Flächengebilden mit Ausnahme von Schmaltextilen anzuwenden sind, wenn deren Oberfläche einer Verformung ausgesetzt wird. Zwei Verfahren werden genannt, von denen das eine (Verfahren A) ein dynamisches Verfahren und das andere (Verfahren B) ein statisches Verfahren ist.
Die erhaltenen Ergebnisse können verglichen werden; die Wahl des Verfahrens sollte zwischen den Parteien vereinbart und im Prüfbericht angegeben werden.

Détermination de l'élasticité des étoffes - Partie 2: Essais multiaxiaux

La présente Norme Européenne spécifie les méthodes d’essai qui peuvent être appliquées pour mesurer l’élasticité et les propriétés afférentes des étoffes lorsqu’elles sont soumises à la déformation de leur surface, à l’exclusion des étoffes étroites. Elle spécifie deux méthodes, l’une dynamique (méthode A) et l’autre statique (méthode B).
Les résultats obtenus ne peuvent être comparés. Il convient que le choix de la méthode fasse l’objet d’un accord entre les parties intéressées et soit indiqué dans le rapport d’essai.

Ugotavljanje elastičnosti ploskovnih tekstilij - 2. del: Multiaksialni preskusi

General Information

Status
Withdrawn
Publication Date
27-Feb-2007
Withdrawal Date
25-Feb-2020
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
26-Feb-2020

Relations

Buy Standard

Standard
EN 14704-2:2007
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Determination of the elasticity of fabrics - Part 2: Multiaxial testsDétermination de l'élasticité des étoffes - Partie 2: Essais multiaxiauxBestimmung der Elastizität von textilen Flächengebilden - Teil 2: Multiaxiale PrüfungenTa slovenski standard je istoveten z:EN 14704-2:2007SIST EN 14704-2:2007en;fr;de59.080.30TkanineTextile fabricsICS:SLOVENSKI
STANDARDSIST EN 14704-2:200701-julij-2007

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14704-2February 2007ICS 59.080.30 English VersionDetermination of the elasticity of fabrics - Part 2: Multiaxial testsDétermination de l'élasticité des étoffes - Partie 2: EssaismultiaxiauxBestimmung der Elastizität von textilen Flächengebilden -Teil 2: Multiaxiale PrüfungenThis European Standard was approved by CEN on 7 January 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14704-2:2007: E

Example of a typical cycling graph.12 Annex B (informative)
Procedure for sampling.13 Annex C (informative)
Example of a pattern for cutting test specimens from a laboratory sample.14 Annex D (informative)
Method A - Dynamic test equipment.15 Annex E (informative)
Method B - Static test equipment.18

Two methods are specified, one a dynamic method (method A) and the other a static method (method B). The results obtained cannot be compared. The choice of method should be agreed between parties and indicated in the test report. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 14704-1, Determination of the elasticity of fabrics — Part 1: Strip tests EN ISO 139, Textiles — Standard atmospheres for conditioning and testing (ISO 139:2005) EN ISO 7500-1, Metallic materials — Verification of static uniaxial testing machines — Part 1: Tension/compression testing machines — Verification and calibration of the force-measuring system
(ISO 7500-1:2004) EN ISO 10012, Measurement management systems — Requirements for measurement processes and measuring equipment (ISO 10012:2003) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 narrow fabric woven or knitted construction intended for use as a trim, binding, edging, strapping or harness, and designed to be used in its full width 3.2 elasticity property of a material by virtue of which it tends to recover its original size and shape immediately after the removal of the force causing deformation 3.3 constant-rate-of-extension (CRE) testing machine tensile testing machine provided with one clamp, which is stationary and another clamp, which moves with a constant speed throughout the test, the entire testing system being virtually free from deflection 3.4 bagging residual deformation, expressed in millimetres, between the original state and the state of the surface when it has undergone a multidirectional force, which by repetition creates a “bag” 3.5 maximum deformation maximum deformation, expressed in millimetres, developed when a specified force is applied to the surface of the test specimen compared to the original state of a test specimen

EN ISO 10012. The constant-rate-of-extension testing machine shall conform to the following. a) The tensile testing machine shall be provided with the means for indicating or recording the force and deformation values when cycling between the original position and either a fixed load or fixed deformation. Under conditions of use, the accuracy of the apparatus shall be at least class 1 of EN ISO 7500-1. The error of the indicated or recorded maximum force at any point in the range in which the machine is used shall not exceed 1 % and the error of the indicated or recorded jaw separation shall not exceed 1 mm. b) If recording of force or elongation is obtained by means of data acquisition boards and software, the frequency of data collection shall be at least eight per second. c) The machine shall be capable of constant rates of distension including 20 mm/min to 500 mm/min with an accuracy of ± 10 %. d) The machine shall be capable of variable gauge length settings including 0 to 100 mm, to an accuracy of ± 1 mm. e) The clamping ring and probe shall be positioned with the centre in line with the applied force. The machine shall be calibrated with the clamp and probe in position. The clamping ring shall be capable of holding the test specimen without allowing it to slip and designed so that it does not cut or otherwise weaken the test specimen (see Annex D). 8.1.2 Equipment for cutting circular test specimens to the required dimensions. 8.1.3 Calibrated metal rule graduated in millimetres. 8.2 Test specimen preparation Each test specimen shall be cut (145 ± 2) mm in diameter (see Annex C). 8.3 Procedure for loading test specimen in clamping ring (see Figures D.1 and D.2) 8.3.1 Position the clamping ring (2) onto loading base (7), place the test specimen face down into the ring, the face of the fabric will be visible to the operator during the test. Next locate holding ring (4) onto the specimen and finally locking ring (5) and screw down on the specimen. 8.3.2 Set the distension rate of the specimen at 100 mm/min for woven and non-woven fabrics and
500 mm/min for knitted. 8.3.3 Fix a suitable load cell to the moving crosshead of the testing machine and then connect the probe. 8.3.4 Set the required cycling limits to cycle between the original position and 10 N (knitted and non-woven) or 50 N (woven) or 100 N (upholstery). Other loading limits can be used as agreed between parties. 8.3.5 Invert the loaded clamping ring with specimen in place onto the base unit (6) which has been attached onto the base of the testing machine (see Figure D.2).

A100×−=VWV
where V is the maximum force from the final cycle; W is the maximum force on the final cycle, after a specified holding period.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.