EN 13384-2:2015
(Main)Chimneys - Thermal and fluid dynamic calculation methods - Part 2: Chimneys serving more than one heating appliance
Chimneys - Thermal and fluid dynamic calculation methods - Part 2: Chimneys serving more than one heating appliance
This part of EN 13384 specifies methods for calculation of the thermal and fluid dynamic characteristics of chimneys serving more than one heating appliance.
This part of EN 13384 covers both the cases, either
a) where the chimney is connected with more than one connecting flue pipe from individual or several appliances in a multi-inlet arrangement; or
b) where the chimney is connected with an individual connecting flue pipe connecting more than one appliance in a cascade arrangement.
The case of multiple inlet cascade arrangement is covered by the case a).
This part of EN 13384 deals with chimneys operating under negative pressure conditions (there can be positive pressure condition in the connecting flue pipe) and with chimneys operating under positive pressure conditions and is valid for chimneys serving heating appliances for liquid, gaseous and solid fuels.
This part of EN 13384 does not apply to:
- chimneys with different thermal resistance or different cross-section in the various chimney segments. This part does not apply to calculate energy gain;
- chimneys with open fire places, e.g. open fire chimneys or chimney inlets which are normally intended to operate open to the room;
- chimneys which serve different kinds of heating appliances regarding natural draught, fan assisted, forced draught or combustion engine. Fan assisted appliances with draught diverter between the fan and the chimney are considered as natural draught appliances;
- chimneys with multiple inlets from more than 5 storeys. (This does not apply to balanced flue chimney.);
- chimneys serving heating appliances with open air supply through ventilation openings or air ducts, which are not installed in the same air supply pressure region (e.g. same side of building).
For positive pressure chimneys this part only applies if any heating appliance which is out of action can be positively isolated to prevent flue gas back flow.
Abgasanlagen - Wärme- und strömungstechnische Berechnungsverfahren - Teil 2: Abgasanlagen mit mehreren Feuerstätten
Dieser Teil der Normenreihe EN 13384 legt Berechnungsverfahren für die wärme- und strömungstechnischen Eigenschaften von Abgasanlagen mit mehreren Feuerstätten fest.
Dieser Teil der EN 13384 umfasst zwei Fälle:
a) senkrechte Teile von Abgasanlagen, in die mehrere Verbindungsstücke von einzelnen oder mehreren zusammengefassten Feuerstätten münden; oder
b) senkrechte Teile von Abgasanlagen, in die ein einzelnes Verbindungsstück mündet, das mehrere Feuerstätten in Kaskadenschaltung verbindet.
Der Fall des Anschlusses mehrerer Kaskadenschaltungen ist durch Fall a) abgedeckt.
Dieser Teil von EN 13384 befasst sich mit Unterdruckabgasanlagen (im Verbindungsstück können Überdruckbedingungen herrschen) sowie mit Überdruckabgasanlagen und gilt für Abgasanlagen mit Feuerstätten für flüssige, gasförmige und feste Brennstoffe.
Dieser Teil der Normenreihe EN 13384 gilt nicht für:
- Abgasanlagen mit unterschiedlichen Wärmedurchlasswiderständen oder unterschiedlichen Querschnitten in den verschiedenen Abschnitten der Abgasanlage. Energiegewinne werden durch diesen Teil der Normenreihe nicht berücksichtigt;
- Abgasanlagen für offene Feuerstätten, z. B. offene Kamine oder Abgaseinführungen in die Abgasanlage, die bestimmungsgemäß offen im Raum betrieben werden;
- Abgasanlagen für verschiedene Feuerstätten mit Unterdruckbetrieb (Naturzug), Gebläseunterstützung oder Verbrennungskraftmaschine. Gebläseunterstützte Abgasanlagen mit einer Nebenluftvorrichtung zwischen Gebläse und Abgasanlage sind als Naturzugkessel anzusehen;
- Abgasanlagen mit Mehrfachanschlüssen aus mehr als 5 Geschossen (dies gilt nicht für Luft-Abgas-Systeme);
- Abgasanlagen für Feuerstätten, denen die Zuluft über Öffnungen ins Freie oder Zuluftleitungen zugeführt wird, die sich druckmäßig nicht im gleichen Luftverbund befinden (z. B. auf der gleichen Seite des Gebäudes).
Bei Überdruckabgasanlagen gilt dieser Teil nur dann, wenn alle nicht in Betrieb befindlichen Feuerstätten sicher abgesperrt werden können, um einen Abgasrückfluss zu verhindern.
Conduits de fumée - Méthodes de calcul thermo-aéraulique - Partie 2: Conduits de fumée desservant plus d'un appareil de chauffage
La présente partie de la norme EN 13384 définit des méthodes de calcul des caractéristiques thermoaérauliques de conduits de fumée desservant plusieurs générateurs de chaleur.
Cette partie de la norme EN 13384 traite des deux cas suivants :
a) cas où le conduit d’évacuation est relié à plusieurs conduits de raccordement partant d'un ou de plusieurs générateurs de chaleur dans un système multi-entrée ou
b) cas où le conduit d’évacuation est relié à un seul conduit de raccordement reliant plusieurs générateurs de chaleur dans un système en cascade.
Le cas du système multi-entrée en cascade est couvert par le cas a).
La présente partie de l'EN 13384 traite des conduits de fumée fonctionnant dans des conditions de pression négative (il peut y avoir une pression positive dans le conduit de raccordement) et des conduits de fumée fonctionnant dans des conditions de pression positive ; elle s'applique à des conduits desservant des générateurs de chaleur pour combustibles liquides, gazeux et solides.
Cette partie de la norme EN 13384 ne s'applique pas aux conduits de fumée suivants :
conduits de fumée présentant une résistance thermique différente ou une section différente dans les différents segments. Cette partie ne s’applique pas pour le calcul du gain énergétique ;
conduits avec foyer ouvert, par exemple conduits de cheminées d'appartements ou entrées de conduits de fumée normalement conçues pour fonctionner ouvertes sur la pièce ;
conduits desservant différentes sortes de générateurs de chaleur : appareils à tirage naturel, ventilés, à tirage forcé ou à moteur à combustion. Les appareils ventilés possédant un coupe-tirage entre le ventilateur et le conduit d’évacuation sont considérés comme des appareils à tirage naturel ;
conduits multi-entrées desservant plus de 5 étages. (Ceci ne s'applique pas aux conduits d’évacuation des produits de combustion et d’amenée d’air comburant) ;
conduits desservant des générateurs de chaleur alimentés à l'air libre par l'intermédiaire d'ouvertures de ventilation ou de conduits aérauliques, qui ne sont pas installés dans la même zone de pression d'alimentation en air (par exemple du même côté du bâtiment) ;
Pour les conduits de fumée sous pression positive, cette partie ne s’applique
Dimniki - Računske metode termodinamike in dinamike fluidov - 2. del: Dimniki za več kot eno ogrevalno napravo
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-2015
1DGRPHãþD
SIST EN 13384-2:2003+A1:2009
'LPQLNL5DþXQVNHPHWRGHWHUPRGLQDPLNHLQGLQDPLNHIOXLGRYGHO'LPQLNL]D
YHþNRWHQRRJUHYDOQRQDSUDYR
Chimneys - Thermal and fluid dynamic calculation methods - Part 2: Chimneys serving
more than one heating appliance
Abgasanlagen - Wärme- und strömungstechnische Berechnungsverfahren - Teil 2:
Abgasanlagen mit mehreren Feuerstätten
Conduit de cheminée - Méthode de calcul thermo-aéraulique - Partie 2: Conduits de
fumée desservant plus d'un appareil de chauffage
Ta slovenski standard je istoveten z: EN 13384-2:2015
ICS:
91.060.40 Dimniki, jaški, kanali Chimneys, shafts, ducts
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 13384-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2015
ICS 91.060.40 Supersedes EN 13384-2:2003+A1:2009
English Version
Chimneys - Thermal and fluid dynamic calculation methods -
Part 2: Chimneys serving more than one heating appliance
Conduits de fumée - Méthodes de calcul thermo-aéraulique Abgasanlagen - Wärme- und strömungstechnische
- Partie 2: Conduits de fumée desservant plus d'un appareil Berechnungsverfahren - Teil 2: Abgasanlagen mit mehreren
de chauffage Feuerstätten
This European Standard was approved by CEN on 24 January 2015.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13384-2:2015 E
worldwide for CEN national Members.
Contents Page
Foreword .5
Introduction .6
1 Scope .7
2 Normative references .7
3 Terms and definitions .8
4 General symbols and abbreviations .9
5 Calculation method.9
5.1 General principles.9
5.2 Pressure equilibrium condition . 11
5.2.1 Negative pressure chimneys . 11
5.2.2 Positive pressure chimneys . 12
5.3 Mass flow requirement . 13
5.4 Pressure requirements . 13
5.4.1 Negative pressure chimneys . 13
5.4.2 Positive pressure chimneys . 14
5.5 Temperature requirement . 15
5.6 Calculation procedure . 15
6 Flue gas data characterising the heating appliance . 18
7 Data for chimney and connecting flue pipes . 19
8 Basic data for the calculation . 20
8.1 General . 20
8.2 Air temperatures . 20
8.2.1 External air temperature (T ) . 20
L
8.2.2 Ambient air temperature (T ) . 20
u
8.3 External air pressure (p ) . 20
L
8.4 Gas constant . 20
8.4.1 Gas constant of the air (R ) . 20
L
8.4.2 Gas constant of flue gas (R) . 20
8.5 Density of air (ρ ) . 20
L
8.6 Specific heat capacity of the flue gas (c ) . 20
p
8.7 Water vapour content (σ(H O) ) and condensing temperature (T ) . 20
2 ,j sp
8.8 Correction factor for temperature instability (S ) . 21
H
8.9 Flow safety coefficient (S ) . 21
E
8.10 External coefficient of heat transfer . 21
9 Determination of temperatures . 21
10 Mixing calculations . 23
10.1 General . 23
10.2 Flue gas mass flow ( m ) . 23
,j
10.3 Flue gas temperature at the inlet of the chimney segment (T ) . 23
e,j
10.4 CO -content of the flue gas in the chimney segment (σ(CO ) ) . 23
2 2 ,j
10.5 H O-content of the flue gas (σ(H O) ) . 24
2 2 ,j
10.6 Gas constant of the flue gas (R ) . 24
,j
10.7 Flue gas data . 24
10.7.1 Specific heat capacity (c ), (c ) . 24
pV,j p,j
10.7.2 Thermal conductivity of the flue gas (λ ), (λ ) . 24
AV,j A,j
10.7.3 Dynamic viscosity (η ), (η ) . 25
AV,j A,j
10.7.4 Condensing temperature (T ) . 25
SP
11 Density and velocity of the flue gas . 25
12 Determination of the pressures . 26
12.1 Pressures at each inlet of the chimney segments . 26
12.1.1 Draught . 26
12.1.2 Positive pressure . 26
12.1.3 Draught due to chimney effect in the chimney segment (P ) . 27
H,j
12.1.4 Pressure resistance in the chimney segment (P ) . 27
R,j
12.2 Minimum draught required at the flue gas inlet into the chimney and maximum allowed
and P ) and maximum and minimum differential pressure at the flue gas
draught (P
Ze Zemax
and P ) . 29
inlet into the chimney (P
ZOe ZOemin
12.2.1 Minimum required and maximum allowed draught . 29
12.2.2 Maximum available and minimum allowed differential pressure . 29
12.2.3 Calculated pressure resistance of the connecting flue pipe (P ) . 30
V,j
12.2.4 Calculated pressure resistance of the air supply (P ) . 32
Bc,j
13 Inner wall temperature . 33
14 Cascade installations . 33
14.1 Principle of the calculation method . 33
14.2 Pressure equilibrium condition . 34
14.2.1 Negative pressure cascade installation . 34
14.2.2 Positive pressure cascade installation . 35
14.3 Mass flow requirement . 36
14.4 Pressure requirements . 36
14.4.1 Negative pressure chimneys . 36
14.4.2 Positive pressure chimneys . 37
14.5 Temperature requirement . 38
14.6 Calculation procedure . 38
14.7 Pressures at the outlet of the connecting flue pipe and pressures at the inlet of the
collector segment . 38
14.7.1 Pressure at the flue gas inlet into the collector segment (P or P ). 38
ZC,j,l ZOC,j,l
14.7.2 Pressures required or available at the outlet of the connecting flue pipe (P , P ) . 42
ZeC,j,l ZOeC,j,l
14.8 Inner wall temperature (T ) . 44
iobC,j,l
15 Balanced flue chimney . 44
15.1 Principle of the calculation method . 44
15.2 Pressure equilibrium condition . 44
15.3 Mass flow requirement .
...