Thermal insulation products for buildings - Factory-made vacuum insulation panels (VIP) - Specification

This document specifies characteristics of factory-made vacuum insulation panels (VIP) intended to be used for the thermal insulation of buildings.
This document is applicable for all types of factory-made vacuum insulation panels (VIP), independent of the core material (see 3.1.10) or type of envelope (see 3.1.11).
This document is applicable for factory-made vacuum insulation panels (VIP) with or without desiccants (see 3.1.12) and with and without evacuation valve (3.1.14).
The products covered by this document can be used in roofs, walls, ceilings and floors.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of factory-made vacuum insulation panels (VIP).
This document does not cover products:
-   intended to be used for the thermal insulation of building equipment and industrial installations;
-   intended to be used for civil engineering works;
-   intended to be used as perimeter or foundation;
-   with a thermal resistance RD lower than 0,5 m2⋅K/W;
-   that contain getters (3.1.13);
-   that have protective layers (3.1.9).

Wärmedämmstoffe für Gebäude - Werksmäßig hergestellte Vakuumisolationspaneele (VIP) - Spezifikation

Dieses Dokument legt die Merkmale für werksmäßig hergestellte Vakuumisolationspaneele (VIP) fest, die für die Wärmedämmung von Gebäuden verwendet werden.
Dieses Dokument gilt für alle Arten von werksmäßig hergestellten Vakuumisolationspaneelen (VIP), unabhängig vom Kernmaterial (siehe 3.1.10) oder der Art der Hülle (siehe 3.1.11).
Dieses Dokument gilt für werksmäßig hergestellte Vakuumisolationspaneele (VIP) mit oder ohne Trocknungsmittel (siehe 3.1.12) und mit oder ohne Evakuierungsventil (3.1.14).
Die von diesem Dokument abgedeckten Produkte können in Dächern, Wänden, Decken und Böden verwendet werden.
Dieses Dokument legt Verfahren zur Bewertung und Überprüfung der Leistungsbeständigkeit (AVCP) von Merkmalen von werksmäßig hergestellten Vakuumisolationspaneelen (VIP) fest.
Dieses Dokument gilt nicht für Produkte
- die für die Wärmedämmung von Haustechnik und Betriebsanlagen vorgesehen sind,
- die für die Verwendung in Hoch- und Tiefbauten vorgesehen sind,
- die als Einfassung oder Fundament verwendet werden sollen,
- die einen niedrigeren Wärmedurchlasswiderstand als 0,5 m2⋅K/W aufweisen,
- die Getter (3.1.13) enthalten, und
- die mit Schutzschichten (3.1.9) versehen sind.

Produits isolants thermiques pour le bâtiment - Panneaux Isolants sous Vide produits de façon industrielle (PIV) - Spécification

Le présent document définit les caractéristiques pour les panneaux isolants sous vide (VIP) produits de façon industrielle, qui sont utilisés pour l’isolation thermique des bâtiments.
Le présent document est applicable à tous les types de panneaux isolants sous vide (VIP) produits de façon industrielle, indépendamment du matériau du coeur (voir 3.1.10) ou du type d’enveloppe (voir 3.1.11).
Le présent document s'applique aux panneaux isolants sous vide (VIP) produits de façon industrielle, avec ou sans dessicant (voir 3.1.12) et avec ou sans soupape d’évacuation (3.1.14).
Les produits couverts par le présent document peuvent être utilisés dans le cadre de travaux sur des toitures, murs, plafonds et sols.
Le présent document définit le mode opératoire à suivre pour l’évaluation et la vérification de la constance des performances (EVCP) des caractéristiques des panneaux isolants sous vide (VIP) produits de façon industrielle.
Le présent document ne couvre pas les produits :
-   conçus pour être utilisés pour l’isolation de l’équipement du bâtiment et des installations industrielles ;
-   conçus pour être utilisés dans le cadre de travaux de génie civil ;
-   conçus pour être utilisés en tant que périmètre ou fondation ;
-   dont la résistance thermique RD est inférieure à 0,5 m2 K/W ;
-   qui contiennent des sorbeurs (3.1.13) ;
-   qui disposent de couches de protection (3.1.9).

Toplotnoizolacijski proizvodi za stavbe - Industrijsko izdelani vakuumski izolacijski paneli (VIP) - Specifikacija

General Information

Status
Published
Publication Date
20-Oct-2020
Withdrawal Date
30-Jul-2022
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
21-Oct-2020
Due Date
08-Sep-2019
Completion Date
21-Oct-2020

Relations

Buy Standard

Standard
EN 17140:2021
English language
63 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2021
Toplotnoizolacijski proizvodi za stavbe - Industrijsko izdelani vakuumski
izolacijski paneli (VIP) - Specifikacija
Thermal insulation products for buildings - Factory made Vacuum Insulation Panels (VIP)
- Specification
Wärmedämmstoffe für Gebäude - Werksmäßig hergestellte Vakuumisolationspanele
(VIP) - Spezifikation
Produits isolants thermiques pour le bâtiment - Panneaux Isolants sous Vide produits de
façon industrielle (VIP) - Spécification
Ta slovenski standard je istoveten z: EN 17140:2020
ICS:
91.100.60 Materiali za toplotno in Thermal and sound insulating
zvočno izolacijo materials
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 17140
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2020
EUROPÄISCHE NORM
ICS 91.100.60
English Version
Thermal insulation products for buildings - Factory-made
vacuum insulation panels (VIP) - Specification
Produits isolants thermiques pour le bâtiment - Wärmedämmstoffe für Gebäude - Werksmäßig
Panneaux Isolants sous Vide produits de façon hergestellte Vakuumisolationspaneele (VIP) -
industrielle (PIV) - Spécification Spezifikation
This European Standard was approved by CEN on 1 September 2020.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 17140:2020 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions, symbols, units and abbreviated terms . 6
3.1 Terms and definitions . 6
3.2 Symbols and abbreviated terms . 7
4 Characteristics . 10
4.1 Reaction to fire . 10
4.2 Propensity to undergo continuous smouldering . 10
4.3 Release of VOCs . 11
4.4 Compressive strength . 11
4.5 Tensile/flexural strength . 11
4.6 Thermal resistance . 12
4.7 Durability aspects . 12
5 Assessment methods . 13
5.1 General . 13
5.2 Test methods . 14
6 Assessment and verification of constancy of performance - AVCP . 21
6.1 General . 21
6.2 Assessment of performance . 21
6.3 Verification of constancy of performance . 23
Annex A (normative) Determination of the expressed values of thermal resistance and
thermal conductivity . 25
Annex B (normative) Factory production control (FPC) . 27
Annex C (normative) Determination of the aged values of thermal resistance and thermal
conductivity including edge effect . 30
Annex D (normative) Measurement of p1/2 of core materials . 40
Annex E (normative) Barrier performance of the envelope . 42
Annex F (normative) Determination of desiccant service life time . 44
Annex G (normative) Measurement of inner pressure . 46
Annex H (normative) Mounting and fixing procedure for reaction to fire tests . 53
Annex ZA (informative) Relationship of this European Standard with Regulation (EU)
No.305/2011 . 58
Bibliography . 62

European foreword
This document (EN 17140:2020) has been prepared by Technical Committee CEN/TC 88 “Thermal
insulating materials and products”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by April 2021, and conflicting national standards shall be
withdrawn at the latest by July 2022.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a standardization request given to CEN by the European
Commission and the European Free Trade Association.
For relationship with (EU) Regulation 305/2011, see informative Annex ZA, which is an integral part of
this document.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
United Kingdom.
1 Scope
This document specifies characteristics of factory-made vacuum insulation panels (VIP) intended to be
used for the thermal insulation of buildings.
This document is applicable for all types of factory-made vacuum insulation panels (VIP), independent
of the core material (see 3.1.10) or type of envelope (see 3.1.11).
This document is applicable for factory-made vacuum insulation panels (VIP) with or without
desiccants (see 3.1.12) and with and without evacuation valve (3.1.14).
The products covered by this document can be used in roofs, walls, ceilings and floors.
This document specifies procedures for assessment and verification of constancy of performance
(AVCP) of characteristics of factory-made vacuum insulation panels (VIP).
This document does not cover products:
— intended to be used for the thermal insulation of building equipment and industrial installations;
— intended to be used for civil engineering works;
— intended to be used as perimeter or foundation;
— with a thermal resistance R lower than 0,5 m ⋅K/W;
D
— that contain getters (3.1.13);
— that have protective layers (3.1.9).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 822:2013, Thermal insulating products for building applications — Determination of length and width
EN 823:2013, Thermal insulating products for building applications — Determination of thickness
EN 824:2013, Thermal insulating products for building applications — Determination of squareness
EN 825:2013, Thermal insulating products for building applications — Determination of flatness
EN 826:2013, Thermal insulating products for building applications — Determination of compression
behaviour
EN 1604:2013, Thermal insulating products for building applications — Determination of dimensional
stability under specified temperature and humidity conditions
EN 1605:2013, Thermal insulating products for building applications — Determination of deformation
under specified compressive load and temperature conditions
EN 1606:2013, Thermal insulating products for building applications — Determination of compressive
creep
EN 1607:2013, Thermal insulating products for building applications — Determination of tensile strength
perpendicular to faces
EN 12090:2013, Thermal insulating products for building applications — Determination of shear
behaviour
EN 12664:2001, Thermal performance of building materials and products — Determination of thermal
resistance by means of guarded hot plate and heat flow meter methods — Dry and moist products of
medium and low thermal resistance
EN 12667:2001, Thermal performance of building materials and products — Determination of thermal
resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium
thermal resistance
EN 13238:2010, Reaction to fire tests for building products — Conditioning procedures and general rules
for selection of substrates
EN 13501-1:2018, Fire classification of construction products and building elements — Part 1:
Classification using data from reaction to fire tests
EN 13820:2003, Thermal insulating materials for building applications — Determination of organic
content
EN 13823:2020, Reaction to fire tests for building products — Building products excluding floorings
exposed to the thermal attack by a single burning item
EN 16516:2017+A1:2020, Construction products: Assessment of release of dangerous substances —
Determination of emissions into indoor air
EN 16733:2016, Reaction to fire tests for building products — Determination of a building product's
propensity to undergo continuous smouldering
EN ISO 1182:2020, Reaction to fire tests for products — Non-combustibility test (ISO 1182:2020)
EN ISO 1716:2018, Reaction to fire tests for products — Determination of the gross heat of combustion
(calorific value) (ISO 1716:2018)
EN ISO 10211:2017, Thermal bridges in building construction — Heat flows and surface temperatures —
Detailed calculations (ISO 10211:2017)
EN ISO 10456:2007, Building materials and products — Hygrothermal properties — Tabulated design
values and procedures for determining declared and design thermal values (ISO 10456:2007)
EN ISO 11925-2:2020, Reaction to fire tests — Ignitability of products subjected to direct impingement of
flame - Part 2: Single-flame source test (ISO 11925-2:2020)
ISO 16269-6:2014, Statistical interpretation of data — Part 6: Determination of statistical tolerance
intervals
As impacted by corrigendum EN ISO 10456:2007/AC:2009.
3 Terms and definitions, symbols, units and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• ISO Online browsing platform: available at https://www.iso.o
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.