This document specifies requirements for assessment of the mechanical strength of metal profiles incorporating a thermal barrier having mechanical performance depending on their intended use.
It also specifies the tests to determine the characteristic values of mechanical properties of the thermal barrier profile and to assess the effect of different conditionings of the thermal barrier on the mechanical performance of the connection.
This document does not apply to thermal barriers which do not give a contribution to the mechanical resistance of the profiles.
This document is applicable to thermal barrier profiles designed mainly for windows, doors, screens and curtain walls.
This document does not apply to thermal barriers made only of metal profiles connected with metal pins or screws.
This current edition of EN 14024 will supersede EN 14024:2004. Differences in test procedures between the two versions will not lead to significant differences in test results. Therefore, existing test results according to EN 14024:2004 are considered as equivalent to new test results according to the current edition of EN 14024.
- Standard63 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft53 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives the tolerance limits for specified dimensions of height, width and thickness, and for squareness of door leaves. It applies to door leaves which are supplied without, and independent of, any frames. It does not apply to the leaves of doorsets.
NOTE Compliance with the tolerance limits given in this document does not imply that this would necessarily produce a perfect fit between door leaves and frames
- Standard4 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies requirements and test methods for the safety in use of power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers power operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This European Standard deals with all significant hazards, hazardous situations and events relevant to the power operation of industrial, commercial and garage doors, and gates when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the machinery including transportation, assembly, dismantling, disabling and scrapping are considered by this standard.
This European Standard does not apply to
- lock gates and dock gates;
- doors on lifts;
- doors on vehicles;
- armoured doors;
- doors mainly for the retention of animals, unless they are at the site perimeter ;
- theatre textile curtains;
- horizontally moving power operated doors mainly intended for pedestrian use;
- doors outside the reach of people (such as crane gantry fences);
- railway barriers;
- barriers intended solely for use by pedestrians;
- barriers used solely for vehicles on motorways.
Whenever the term "door" is used in this document, it shall be deemed to cover the full scope of types and variances of doors, gates and barriers in the scope of this Standard.
This European Standard does not deal with any specific requirements on noise emitted from power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises as their noise emission is not considered to be a relevant hazard.
NOTE Noise emission of power operated doors is not a significant hazard for the users of these products. It is a comfort aspect.
This European Standard is not applicable to machinery which are manufactured before the date of publication of the standard.
- Standard68 pagesEnglish languagesale 10% offe-Library read for×1 day
- 21-Dec-2021
- 29-Jun-2022
- 91.060.50
- 2006/42/EC
- M/396
- CEN/TC 33
This document specifies a test method for the determination of resistance to static loading in order to assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically), projecting, and rolling as well as non-openable constructions.
It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer’s installation instructions is given in EN 1627:2021, Annex A.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
- Standard88 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft87 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and classification systems for burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically), projecting and rolling as well as non-openable constructions. It also covers products that include items such as letter plates or ventilation grilles. It specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this document).
NOTE 1 The elements of curtain walling will be assigned to group 1 to 4 product depending on their design.
This document does not directly cover the resistance of locks and cylinders to attack with picking tools. Building hardware are components of the above mentioned products and cannot be classified as such according to this document.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE 2 It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
The requirements to an electronic security system (e.g. access control system) to control electromechanical locks and strikes according to EN 14846:2008 are not in the scope of this document.
NOTE 3 Locks and striking plates according to EN 14846:2008 needs an access control system for authorized and secure access (comparable to a lock cylinder). The transmission of the signal between the lock and the access control system (e.g. wiring) needs also consideration. (The signal is transmitted in encrypted form or is not accessible during the manual attack attempt.) Upcoming revisions of this document might include such a reference.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft57 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a test method for the determination of resistance to manual burglary attempts in order to assess the burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically), projecting, and rolling as well as non-openable constructions.
This document does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using surreptitious attack methods that might defeat these characteristics.
It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer’s installation instructions is given in EN 1627:2021, Annex A.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
- Standard47 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft43 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is applicable to power-operated pedestrian swing door drives with self closing function using mechanically stored energy for single and double leaf swing doorsets with or without fire resistance and smoke control characteristics. It defines requirements and test methods for the self-closing function.
This document does not apply to:
- electrically controlled hold-open systems according to EN 14637;
- door coordinating devices according to EN 1158;
- electrically powered hold-open devices for swing doors according to EN 1155.
Requirements and test methods for hold-open systems are not part of this document.
Additional requirements and test methods for the use of power-operated pedestrian swing door drives with self closing function on double-leaf swing doors are described in EN 1158 and are therefore not part of this document.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), projecting, pivoted (horizontally and vertically) and rolling as well as non-openable constructions.
It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer's installation instructions is given in EN 1627:2021, Annex A.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
- Standard41 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft40 pagesEnglish languagesale 10% offe-Library read for×1 day
This document defines test and calculation methods for the determination of the reflection and transmission characteristics to be used to determine the thermal and visual comfort performance classes of external blinds, internal blinds and shutters, as specified in EN 14501:2021.
This document also specifies the method to determine the darkening performance of external blinds, internal blinds and shutters, as specified in EN 14501:2021.
This document applies to the whole range of shutters, awnings and blinds defined in EN 12216, described as solar protection devices in this document. Some of the characteristics (e.g. gtot) are not applicable when products are not parallel to the glazing (e.g. folding-arm awnings).
NOTE 1 Informative Annex D presents an approach for the determination of characteristics in case of projectable products.
Retro-reflecting products are outside the scope of this document for reflectance measurements.
NOTE 2 Retro-reflecting products refer to products for which the reflected radiation comes back to the light source in the same direction.
Products using a significant amount of fluorescent are outside the scope of this document.
NOTE 3 "Significant amount" refers to materials which are designed to be fluorescent or retroreflective and marketed as such. It does not refer to trace amounts of materials exhibiting fluorescence, e.g. for colour or identification purposes. Small amounts of materials such as titanium dioxide, which are not primarily included to achieve fluorescence, can be present.
- Standard85 pagesEnglish languagesale 10% offe-Library read for×1 day
This document applies to the whole range of shutters, awnings and blinds defined in EN 12216, described as solar protection devices in this document.
It specifies the corresponding properties and classifications:
- relating to thermal comfort:
- the solar factor (total solar energy transmittance);
- the secondary heat transfer factor;
- the direct solar transmittance;
- relating to visual comfort:
- the darkening performance;
- the night privacy;
- the visual contact with the outside;
- the glare control;
- the daylight utilization;
- the rendering of colours.
NOTE For other purposes, more detailed methods using different parameters can be used.
Some of the characteristics (e.g. gtot) are not applicable when solar protection devices are not parallel to the glazing (e.g. folding-arm awnings).
This document is not applicable to the solar protection devices using fluorescent materials.
- Standard45 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.