prEN 845-2
(Main)Specification for ancillary components for masonry - Part 2: Lintels
Specification for ancillary components for masonry - Part 2: Lintels
This part of EN 845 specifies requirements for prefabricated lintels up to a maximum clear span of 4,5 m made from autoclaved aerated concrete, fired clay units, calcium silicate units, natural or manufactured stone, concrete and steel or using a combination of these materials. Product characteristics linked to ER1 are flexural resistance, shear load resistance and stiffness.
Festlegungen für Hilfsbauteile für Mauerwerk - Teil 2: Stürze
Dieser Teil von EN 845 legt Anforderugnen an vorgefertigte Stürze mit einer lichten Weite von maximal 4,5 m aus Porenbeton, gebrannten Mauerziegeln, Kalksandsteinen, Natursteinen oder Betonwerksteinen, Beton oder Stahl oder aus einer Kombination dieser Materialien fest. Anmerkung 1: Stürze werden in einem Stück zur Baustelle geliefert. Sie können auf der Baustelle mit Beton oder Mauerwerk (teilweise vorgefertigte bauseits ergänzte Stürze) oder mit einem anderen Sturz (zusammengesetzte Stürze) ergänzt werden; sie sollten aber im Anlieferungßustand in der Lage sein, eine Last zu übertragen.
Spécification pour éléments auxiliaires de maçonnerie - Partie 2: Linteaux
Cette partie de la norme EN 845 spécifie les exigences relatives aux linteaux préfabriqués d'une portée maximum de 4,5 m réalisés à partir de béton cellulaire autoclavé, d'éléments en terre cuite, d'éléments en silico-calcaire, en pierre naturelle ou artificielle, en béton et en acier ou qui combinent ces matériaux. Note 1: Les linteaux sont livrés sur le chantier en une seule pièce. Ils peuvent être complétés sur le chantier par du béton ou des éléments de maçonnerie (linteau composite) ou par un autre linteau (linteau combiné), mais ils doivent être à même de supporter une charge dans l'état où ils sont livrés
Specifikacija za dodatne komponente zidovja - 2. del: Preklade
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN 845-2:2010
01-marec-2010
Specifikacija za dodatne komponente zidovja - 2. del: Preklade
Specification for ancillary components for masonry - Part 2: Lintels
Festlegungen für Ergänzungsbauteile für Mauerwerk - Teil 2: Stürze
Spécifications pour composants accessoires de maçonnerie - Partie 2: Linteaux
Ta slovenski standard je istoveten z: prEN 845-2
ICS:
91.060.10 Stene. Predelne stene. Walls. Partitions. Facades
Fasade
91.080.30 Zidane konstrukcije Masonry
oSIST prEN 845-2:2010 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 845-2:2010
---------------------- Page: 2 ----------------------
oSIST prEN 845-2:2010
EUROPEAN STANDARD
DRAFT
prEN 845-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2010
ICS 91.080.30 Will supersede EN 845-2:2003
English Version
Specification for ancillary components for masonry - Part 2:
Lintels
Spécifications pour composants accessoires de Festlegungen für Ergänzungsbauteile für Mauerwerk - Teil
maçonnerie - Partie 2: Linteaux 2: Stürze
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 125.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the
same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 845-2:2010: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
oSIST prEN 845-2:2010
prEN 845-2:2010 (E)
Contents Page
Foreword . 3
1 Scope. 4
2 Normative references . 4
3 Terms, definitions and symbols . 6
3.1 Terms and definitions . 6
3.2 Symbols . 8
4 Materials . 12
4.1 Steel lintels . 12
4.2 Concrete lintels . 12
4.3 Masonry lintels . 12
4.4 Combined and composite lintels . 13
5 Requirements . 13
5.1 General . 13
5.2 Dimensions, mass and limit deviations . 14
5.3 Mechanical performance and inform
...
Questions, Comments and Discussion