Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 006: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Dual extruded wall for open applications, with jacket and screen (braid) - UV laser printable - Product standard

This document specifies the characteristics of UV laser printable jacket, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft operating at temperatures between – 65 °C and 135 °C, operating at voltages not exceeding 600 V rms at sea level. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user.
These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen zur allgemeinen Verwendung - XLETFE-Familie - Ummantelt oder geschirmt und ummantelt - Teil 006: Kupfer verzinnt - Betriebstemperaturen zwischen -65 °C und 135 °C - doppelt extrudierte Isolierung für offene Anwendungen, ummantelt und geschirmt (Geflecht) - UV-Laser bedruckbar - Produktnorm

Dieses Dokument legt die Eigenschaften von elektrischen Leitungen mit UV Laser-bedruckbarem Mantel, verzinntem Kupferleiter, aus der XLETFE Familie (quervernetztes Ethylen Tetrafluorethylen Co Polymer) zur Verwendung in elektrischen Bordnetzen von Luftfahrzeugen für Betriebstemperaturen zwischen −65 °C und 135 °C und Spannungen bis 600 V (Effektivwert) auf Meereshöhe fest. Dieses Isoliersystem wurde bei Luft  und Raumfahrtanwendungen mit 115 V (Phase gegen Neutral), 400 Hz Wechselspannung und 28 V Gleichspannung angewendet. Der Anwender ist für den Nachweis der Eignung von Leitungen zur Anwen¬dung in anderen elektrischen Systemen verantwortlich.
Diese Leitungen sind für die Verlegung in Luftfahrzeugzellen ohne Zusatzschutz geeignet. Bei Wider¬sprü-chen zwischen dieser Norm und anderen zitierten Dokumenten gelten die Anforderungen dieser Norm.

Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 006 : Cuivre étamé - Températures de fonctionnement comprises entre - 65 °C et 135 °C - Fil double isolé pour applications externes, gainé et blindé (tressé) - Marquable au laser UV - Norme de produit

Le présent document spécifie les caractéristiques des câbles électriques conducteurs en cuivre étamé gainés, marquables au laser UV, de la famille des copolymères d'éthylène tétra-fluoro éthylène réticulés (XLETFE), utilisés dans les systèmes électriques de bord des aéronefs à une température de fonctionnement comprise entre – 65 °C et 135 °C, à des tensions n’excédant pas 600 V rms au niveau de la mer. Ce système isolant est employé dans les applications aérospatiales utilisant une tension simple de 115 V (phase-neutre) 400 Hz ca et 28 V cc. Il est de la responsabilité de l'utilisateur de vérifier si les câbles sont utilisables dans d'autres systèmes électriques.
Ces câbles sont utilisables en cellule sans protection supplémentaire. En cas de conflit entre cette norme et d'autres documents de référence, les exigences de la présente norme doivent prévaloir.

Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina XLETFE - Oplaščeni ali zaslonjeni in oplaščeni - 006. del: Pocinjeni baker - Obratovalne temperature med –65 °C in 135 °C - Dvojno ekstrudirana izolacija za zunanjo uporabo, s plaščem in zaslonom (opletom) - Potiskljiva z UV-laserjem - Standard za proizvod

Ta dokument določa lastnosti električnih oplaščenih kablov, potiskljivih z UV-laserjem, z vodnikom iz pocinjenega bakra iz družine kopolimerov, pridobljenih z mrežno polimerizacijo etilena in tetrafluoroetilena (XLETFE), za uporabo v električnih sistemih na krovu letal pri obratovalnih temperaturah med –65 in 135 °C in obratovalnih napetostih, ki ne presegajo 600 V RMS na morski gladini. Ta izolacijski sistem se je uporabljal v aeronavtiki pri izmenični napetosti 115 V (za fazno napetost) pri 400 Hz in 28 V pri enosmerni napetosti. Za preverjanje ustreznosti kablov za uporabo v drugih električnih sistemih je odgovoren uporabnik. Ti kabli so primerni za uporabo na ogrodjih letal brez dodatne zaščite. V primeru neskladja med tem standardom in drugimi navedenimi dokumenti imajo prednost določila tega standarda.

General Information

Status
Published
Publication Date
20-Aug-2019
Withdrawal Date
28-Feb-2020
Technical Committee
Drafting Committee
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
21-Aug-2019
Completion Date
21-Aug-2019

Relations

Buy Standard

Standard
EN 4612-006:2019
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 4612-006:2019
01-november-2019
Nadomešča:
SIST EN 4612-006:2012
Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina
XLETFE - Oplaščeni ali zaslonjeni in oplaščeni - 006. del: Pocinjeni baker -
Obratovalne temperature med –65 °C in 135 °C - Dvojno ekstrudirana izolacija za
zunanjo uporabo, s plaščem in zaslonom (opletom) - Potiskljiva z UV-laserjem -
Standard za proizvod
Aerospace series - Cables, electrical, for general purpose, single and multicore
assembly - XLETFE Family - Jacketed or screened and jacketed - Part 006: Tin plated
copper - Operating temperatures, between -65 °C and 135 °C - Dual extruded wall for
open applications, with jacket and screen (braid) - UV laser printable - Product standard
Luft- und Raumfahrt - Ein- und mehradrige elektrische - Leitungen für allgemeine
Verwendung - XLETFE Familie - mit Mantel oder geschirmt und Mantel - Teil 006: Kupfer
verzinnt - Betriebstemperaturen zwischen -65 °C und 135 °C - Doppelt extrudierte
Isolierung für externe Verwendung, mit Mantel und Schirm (Geflecht) - UV-Laser
bedruckbar - Produktnorm
Ta slovenski standard je istoveten z: EN 4612-006:2019
ICS:
29.060.20 Kabli Cables
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
SIST EN 4612-006:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 4612-006:2019

---------------------- Page: 2 ----------------------
SIST EN 4612-006:2019


EN 4612-006
EUROPEAN STANDARD

NORME EUROPÉENNE

August 2019
EUROPÄISCHE NORM
ICS 49.060 Supersedes EN 4612-006:2011
English Version

Aerospace series - Cables, electrical, for general purpose,
single and multicore assembly - XLETFE Family - Jacketed
or screened and jacketed - Part 006: Tin plated copper -
Operating temperatures, between - 65 °C and 135 °C - Dual
extruded wall for open applications, with jacket and screen
(braid) - UV laser printable - Product standard
Série aérospatiale - Câbles, électriques, d'usage Luft- und Raumfahrt - Ein- und mehradrige elektrische
général, mono et multiconducteurs - Famille XLETFE Leitungen zur allgemeinen Verwendung - XLETFE-
- Gainés ou blindés et gainés - Partie 006 : Cuivre Familie - Ummantelt oder geschirmt und ummantelt -
étamé - Températures de fonctionnement comprises Teil 006: Kupfer verzinnt - Betriebstemperaturen
entre - 65 °C et 135 °C - Fil double isolé pour zwischen -65 °C und 135 °C - doppelt extrudierte
applications externes, gainé et blindé (tressé) - Isolierung für offene Anwendungen, ummantelt und
Marquable au laser UV - Norme de produit geschirmt (Geflecht) - UV-Laser bedruckbar -
Produktnorm
This European Standard was approved by CEN on 5 May 2019.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATIO N

EUROPÄISCHES KOMITEE FÜR NORMUN G

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 4612-006:2019 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 4612-006:2019
EN 4612-006:2019 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms, definitions and symbols .
...

Questions, Comments and Discussion