Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

IEC 61009-1:2010 applies to residual current operated circuit breakers with integral overcurrent protection functionally independent of, or functionally dependent on, line voltage for household and similar uses (hereafter referred to as RCBOs), for rated voltages not exceeding 440 V a.c. with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A and rated short circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition, published in 1996, amendment 1 (2002) and amendment 2 (2006). It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - complete revision of EMC sequences, including the new test T.2.6, already approved in IEC 61543; - clarification of RCDs current/time characteristics reported in Tables 2 and 3; - revision of test procedure for IΔn between 5 A and 200 A; - tests for the use of RCBOs in IT systems; - testing procedure regarding the 6mA d.c. current superimposed to the fault current; - improvement highlighting RCDs with multiple sensitivity; - some alignments with IEC 60898-1.

Fehlerstrom-/Differenzstrom-Schutzschalter mit eingebautem Überstromschutz (RCBOs) für Hausinstallationen und für ähnliche Anwendungen - Teil 1: Allgemeine Anforderungen

Interrupteurs automatiques à courant différentiel résiduel avec dispositif de protection contre les surintensités incorporé pour usages domestiques et analogues (DD) - Partie 1: Règles générales

La CEI 61009-1:2010 s'applique aux interrupteurs automatiques avec protection contre les surintensités incorporé, à courant différentiel résiduel, fonctionnellement indépendants ou fonctionnellement dépendants de la tension d'alimentation, pour installations domestiques et analogues (en abrégé 'DD' dans la suite du texte), ayant une tension assignée ne dépassant pas 440 V alternatifs, avec des fréquences assignées de 50 Hz, 60 Hz ou 50/60 Hz et un courant assigné ne dépassant pas 125 A et un pouvoir de coupure ne dépassant pas 25 000 A pour fonctionnement à 50 Hz ou 60 Hz. Cette troisième édition annule et remplace la deuxième édition, publiée en 1996, ainsi que l'amendement 1 (2002) et l'amendement 2 (2006), dont elle constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: - révision complète des séquences CEM, incluant le nouvel essai T.2.6, déjà approuvé dans la CEI 61543; - clarification des caractéristiques courant/temps des DDR incluses dans les Tableaux 2 et 3; - révision de la procédure d'essai pour IΔn entre 5 A et 200 A; - essais pour l'emploi des DD dans les systèmes IT; - procédure d'essai concernant le courant continu 6 mA superposé au courant de défaut; - des améliorations mettant en relief les DDR avec sensibilité multiple; - des alignements avec la CEI 60898-1.

Odklopniki na preostali (residualni) tok z vgrajeno nadtokovno zaščito za gospodinjsko in podobno rabo (RCBO's) - 1. del: Splošna pravila (IEC 61009-1:2010, spremenjen)

Ta mednarodni standard se uporablja za odklopnike na preostali (residualni) tok z vgrajeno nadtokovno zaščito, ki so funkcionalno neodvisni ali odvisni od linijske napetosti, za gospodinjsko in podobno rabo (v nadaljnjem besedilu: RCBO), za nazivne napetosti do vključno 440 V izmenične napetosti, pri čemer nazivna frekvenca dosega 50 Hz, 60 Hz ali 50/60 Hz, nazivni tok ne presega 125 A, nazivne kratkostične zmogljivosti pa ne presegajo 25000 A med delovanjem pri 50 Hz ali 60 Hz. Te naprave so namenjene zaščiti oseb pred posrednim stikom, pri čemer so izpostavljeni prevodni deli inštalacije povezani z ustreznim ozemljilom, in zaščiti napeljav stavb in podobnih aplikacij pred nadtoki. Uporabljajo se lahko za zaščito pred požarom zaradi stalnega ozemljitvenega okvarnega toka brez naprave za nadtokovno zaščito. Tudi odklopniki na preostali (residualni) tok z vgrajeno nadtokovno zaščito (RCBO) z nazivnim preostalim operativnim tokom do vključno 30 mA se uporabljajo kot dodatna zaščita v primeru odpovedi zaščitnega sredstva pred električnim udarom. Ta standard se uporablja za naprave, ki hkrati izvajajo funkcije zaznavanja preostalega (residualnega) toka, primerjanja vrednosti tega toka s preostalo operativno vrednostjo in odprtja zaščitenega tokokroga, kadar preostali tok presega to vrednost, ter tudi funkcijo ustvarjanja, prenosa in prekinitve nadtokov pod določenimi pogoji. Odklopniki RCBO splošnega tipa se ne morejo po nesreči odklopiti, tudi kadar previsoka napetost (zaradi prehodnih preklapljanj ali udara strele) povzroči obremenilne tokove v inštalaciji brez nastanka preboja. Odklopniki RCBO tipa S naj bi v zadostni meri ščitili pred neželenim odklopom, celo kadar previsoka napetost povzroči preboj in nastane nadaljnji tok. Odklopniki RCBO so primerni za izolacijo. Odklopniki RCBO, ki so skladni s tem standardom, razen odklopnikov z neprekinjeno nevtralno točko, so primerni za uporabo v sistemih IT. Posebni zaščitni ukrepi (npr. prenapetostni odvodniki) so lahko potrebni, kadar lahko na strani dobave nastane prekomerna prenapetost (na primer v primeru dobave prek nadzemnih vodov) (glejte standard 60364-4-44). Ta standard se uporablja tudi za odklopnike RCBO, ki se pridobijo z montažo naprave s prilagodljivim preostalim (residualnim) tokom z odklopnikom. Mehansko montažo izvede proizvajalec v tovarni ali se opravi na kraju samem, v tem primeru pa se uporabljajo zahteve Dodatka G. Uporablja se tudi za odklopnike RCBO z več kot enim nazivnim tokom, če sredstvo za spreminjanje nazivnega toka ni na voljo med običajnim delovanjem in se nazivni tok ne more spremeniti brez uporabe orodja. Dodatne zahteve so lahko potrebne za vtične odklopnike RCBO. Posebne zahteve so potrebne za odklopnike RCBO, vgrajene v ali namenjene le uporabi z vtiči in vtičnicami ali s spojkami naprave za gospodinjsko in podobno splošno rabo in če so namenjeni uporabi pri frekvencah, ki niso 50 Hz ali 60 Hz. Ta standard se ne uporablja za: – odklopnike RCBO, namenjene zaščiti motorjev; – odklopnike RCBO, katerih trenutno nastavitev je mogoče prilagoditi s sredstvi, ki so uporabniku na voljo med običajnim delovanjem. Zahteve tega standarda se uporabljajo za običajne okoljske pogoje. Dodatne zahteve so lahko potrebne za odklopnike RCBO, ki se uporabljajo na lokacijah z neugodnimi okoljskimi pogoji. Ta standard ne zajema odklopnikov RCBO z akumulatorji. V Dodatku F so zajeta navodila za usklajevanje odklopnikov RCBO z varovalkami.

General Information

Status
Published
Publication Date
13-Dec-2012
Withdrawal Date
17-Jun-2017
Current Stage
6060 - Document made available - Publishing
Start Date
14-Dec-2012
Completion Date
14-Dec-2012

Relations

Buy Standard

Standard
EN 61009-1:2013
English language
193 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61009-1:2013
01-februar-2013
1DGRPHãþD
SIST EN 61009-1:2005
SIST EN 61009-1:2005/A11:2008
SIST EN 61009-1:2005/A12:2009
SIST EN 61009-1:2005/A13:2009
SIST EN 61009-1:2005/A14:2012
SIST EN 61009-1:2005/A14:2012/AC:2013
2GNORSQLNLQDSUHRVWDOL UHVLGXDOQL WRN]YJUDMHQRQDGWRNRYQR]DãþLWR]D
JRVSRGLQMVNRLQSRGREQRUDER 5&%2
V GHO6SORãQDSUDYLOD ,(&
VSUHPHQMHQ
Residual current operated circuit-breakers with integral overcurrent protection for
household and similar uses (RCBOs) - Part 1: General rules (IEC 61009-1:2010,
modified)
Fehlerstrom-/Differenzstrom-Schutzschalter mit eingebautem Überstromschutz (RCBOs)
für Hausinstallationen und für ähnliche Anwendungen -- Teil 1: Allgemeine
Anforderungen (IEC 61009-1:2010, modifiziert)
Interrupteurs automatiques à courant différentiel résiduel avec dispositif de protection
contre les surintensités incorporé pour usages domestiques et analogues (DD) - Partie 1:
Règles générales( CEI 61009-1:2010, modifiée)
Ta slovenski standard je istoveten z: EN 61009-1:2012
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
SIST EN 61009-1:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61009-1:2013

---------------------- Page: 2 ----------------------

SIST EN 61009-1:2013


EUROPEAN STANDARD
EN 61009-1

NORME EUROPÉENNE
December 2012
EUROPÄISCHE NORM

ICS 29.120.50 Supersedes EN 61009-1:2004 + corr. Jul.2006 + A11:2008 + A12:2009 + A13:2009
+ A14:2012 + AC:2012


English version


Residual current operated circuit-breakers with integral overcurrent
protection for household and similar uses (RCBOs) -
Part 1: General rules
(IEC 61009-1:2010, modified)


Interrupteurs automatiques à courant Fehlerstrom-/Differenzstrom-
différentiel résiduel avec dispositif de Schutzschalter mit eingebautem
protection contre les surintensités Überstromschutz (RCBOs) für
incorporé pour usages domestiques et Hausinstallationen und für ähnliche
analogues (DD) - Anwendungen -
Partie 1: Règles générales Teil 1: Allgemeine Anforderungen
(CEI 61009-1:2010, modifiée) (IEC 61009-1:2010, modifiziert)




This European Standard was approved by CENELEC on 2012-06-18. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61009-1:2012 E

---------------------- Page: 3 ----------------------

SIST EN 61009-1:2013
EN 61009-1:2012 - 2 -

Foreword

This document (EN 61009-1:2012) consists of the text of IEC 61009-1:2010 prepared by IEC/TC 23E
"Circuit-breakers and similar equipment for household use", together with the common modifications
prepared by CLC/TC 23E "Circuit breakers and similar devices for household and similar applications".


The following dates are fixed:

(dop) 2013-06-18
• latest date by which this document has to be
implemented
at national level by publication of an identical
national standard or by endorsement
• latest date by which the national standards conflicting (dow) 2017-06-18
with this document have to be withdrawn

This document supersedes EN 61009-1:2004 + corr.Jul.2006 + A11:2008 + A12:2009 + A13:2009 +
A14:2012 + AC:2012.
– complete revision of EMC sequences, including the new test T.2.6, already approved in EN 61543;
– clarification of RCDs current/time characteristics reported in Tables 2 and 3;
– revision of test procedure for I between 5 A and 200 A;
Δn
– tests for the
...